5
Mounting
5.1
Mounting requirements
■
Comply with technical data such as the permitted ambient conditions for operation
of the sensor (e.g., temperature range, EM interference),
.
■
Protect the sensor from direct sunlight.
■
Only mount sensor with the intended accessories.
Mounting location
When selecting the mounting location, the following factors must be considered:
■
The mounting location must be as free from (electro)magnetic disturbance fields
as possible
5.2
Optional accessories
Table 2: Optional accessories
Part number
Designation
4107585
Control panel mounting
4106971
T-slot adapter
5.3
Mounting
Insert sensor into the slot from above. The
PWR LED
1)
lights up green and the
MR LED
2)
lights up yellow when the magnet is located in the measuring range.
If the user does not teach in the measuring range, the standard measuring range of
+/-25 mm is used.
1
2
3
1
Insert sensor
2
Turn sensor
3
Tighten screws (tightening torque max. 0.1 Nm)
1)
PWR LED = Power LED
2)
MR LED = Measuring Range LED
5
MOUNTING
14
O P E R A T I N G I N S T R U C T I O N S | MPS-G with analog output
8025941/2020-07-16 | SICK
Subject to change without notice