5
Mounting
5.1
Mounting instructions
•
Observe the technical data.
•
To prevent condensation, avoid exposing the device to rapid changes in tempera‐
ture.
•
The mounting site has to be designed for the weight of the device.
•
It should be mounted so that it is exposed to as little shock and vibration as possi‐
ble. Optional mounting accessories are available,
•
Use a stable bracket with sufficient load-bearing capacity and suitable dimensions
for the device.
•
Ensure that the device has a clear view of the object to be detected.
•
Protect the device from moisture, contamination, and damage.
•
Ensure a sufficient level of cooling using ambient air/convection and/or heat
dissipation through mechanical mounting. Observe the permitted operating tem‐
perature,
5.2
Mounting the device
Mount the device in a position above the surface to be scanned. See
for field of view diagrams and mounting distances. The default
scan direction is shown in
. If a scan is performed in the opposite direction, the
acquired image will be mirrored.
Figure 5: Mounting position
5.3
Field of view diagrams
The maximum guaranteed image acquisition area in mm (inch) is shown for each
device variant. The brighter areas represent typical image acquisition areas.
5
MOUNTING
22
O P E R A T I N G I N S T R U C T I O N S | TriSpectorP1000
8022395/19OK/2020-12 | SICK