SYSTEM DESCRIPTION
3
33
8020776/12AX / 2019-05-31|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S |Free Flow Profiler
3.3.6
Data processing in the Traffic Controller FPS
All the measured values converge in the Traffic Controller FPS. The TEMS Recorder
processes the raw data supplied in a continuous data stream. The data in this stream are
supplemented and consolidated. At the end of the data processing flow, data are output
via the TCP/IP interface (TEMS Info interface).
All of the profiling system functions are structured
hierarchically
for data processing.
This structure is defined in the system configuration.
•
At the start of the process, the
initial system function
records the basic data. This
supplies the vehicle data.
•
The
subsequent system functions
add to the basic data.
The figure below illustrates how the initial vehicle data are continuously supplemented by
the measurement results of the individual system functions.
At the end of the data processing flow, data are output to the higher-level system via the
TCP/IP interface.
Fig. 24: How data are processed in the Traffic Controller FPS