The safety laser scanner has 4 M5 threaded holes on the back. If you are able to drill
through the mounting surface from the rear, you can mount the safety laser scanner
directly using these threaded holes.
b
Use either the rear
1
or the side
2
M5 threaded holes for direct mounting.
b
Use all four rear or all four side M5 threaded holes for direct mounting, so that the
values given in the data sheet for vibration and shock resistance are achieved.
b
Maximum depth of thread engagement: 7.5 mm.
b
Tightening torque: 4.5 Nm to 5.0 Nm.
6
Connection overview
MICSX-BANNZZZZ1 (part number: 2086102)
XF1
XF2
XD1
XD1
Voltage supply
XF1, XF2
Ethernet for safety-related data communication, data output, configuration and
diagnostics
MICSX-BANNEZZZ1 (part number: 2081021)
XD1
XF1
XF2
XF3
XD1
Voltage supply
XF1
Ethernet for EtherCAT IN
XF2
Ethernet for EtherCAT OUT
XF3
Ethernet (not safety-related)
7
Pin assignment
7.1
Voltage supply (XD1)
Male connector, M12, 4-pin, A-coded.
1
2
3
4
MOUNTING INSTRUCTIONS
8020210/16V7/2020-03-16 | SICK
M O U N T I N G I N S T R U C T I O N S | microScan3 – EFI-pro, microScan3 – EtherCAT®, microScan3 – PROFINET (M12),
microScan3 – EtherNet/IP™
13
Subject to change without notice