TECHNICAL DATA SHEET FOR INDIRECT FIRED OIL HEATERS – 37 kW MODEL
Thermal Specifications
Airflow Specifications
Electrical Specifications
Maximum Thermal Power (Diesel Oil)
Air Flow Rating
Rated Voltage
Consumption
Kg/hr
at 3°C (37F)
2,88 m³/h
2000 m³/h
1180 ft³/min
V/Hz
110/60
U.S. gal/hr
0,90
Efficiency
%
87,10 Fan Diameter
Rated Current
Power Input
kcal/hr
31304 mm
350 mm
14 in
A
7,0
kW
36,40 Blade #
3 sickle-shaped
BTU/hr
125216 Pitch
18°
Rated Power
Power Output
kcal/h
27266
W
460
kW
31,70 Temperature Rise (Delta)
BTU/hr
109063
at 20°C (68 F)
54°C
97 F
Motor Power
Fuel Pressure
W
430
12 bar 175 psi Noise Level
at 1 m
at 2 m
dB(A) average
77
75
Rotational Speed
Smoke Index
with original hood
rpm
3400
1,00
Air Lock Adjustment
Nozzle Type
Fuse
mm
3,0 Manufacturer
DANFOSS
A
15 slow-blow
Type
60° H
Maximum Thermal Power (Kerosene)
Flow Rate
GPH
0,65
Size Specifications
Consumption
Kg/hr
2,64
Weight
Tank Capacity
Efficiency
%
87,10 Air Ducting
70 kg
154 lb
51 liters
14 U.S. gal
Power Input
kcal/hr
29106 Hose Diameter
Lenght
Outlet Diameter
kW
33,84
315 mm
12 in
1188 mm
47 in
308 mm
12 in
BTU/hr
116425 Maximum Hose Lenght
Width
Flue Diameter
Power Output
kcal/hr
25352
8 m
25 ft
620 mm
24 in
150 mm
6 in
kW
29,48
Height
BTU/hr
101406
790 mm
31 in
Fuel Pressure
psi
12,00
*oil gross heating value Kcal/kg
10869,44
Package Specifications
Air Lock Adjustment
*kerosene gross heating value Kcal/kg
11.025,08
Lenght
1250 mm Height
830 mm
mm
3,00 according to standard prEN 13842:2002
Width
530 mm Weight