Manu_ENG_UFO_ rev. 0_04_2012
pag. 9
MINIMUM height of installation (for people comfort)
Indicative heights for the installation of appliances are as follows:
MODEL
HEIGHT of INSTALLATION (mt)
MIN
MAX
UFO EB / 08
2,5
3,5
(electronic start-up, TWO-STAGES version)
UFO M / 08
2,0
2,5
(manual start-up, ON-OFF version)
Height “MIN" means the minimum height at which the appliance should be installed so that
people who are in radiated zone, are not subject to excessive heat.
Quotes relate to installation with ambient temperature of 10 ÷ 12 °C; in case of ambient
with higher or lower temperatures the minimum height of installation must be reviewed;
consider a reduction of 5 % (for temperatures lower of approx. 5 ° C) or increase of 5 % (for
temperatures higher of approx. 5 ° C).
Above MINIMUM heights of installation are indicative, consult us each case to select the
most advisable unit and the best height of installation (mostly for limit values).
MINIMUM distances from flammable surfaces
IMPORTANT: flammable materials inside the radiation could begin to burn and cause fires.
Minimum distances of installation must be respected between the heating surface of the
appliances and the adjacent walls, inside the area of radiation and outside, if they are
not protected against radiation or are flammable materials.
The MINIMUM distances are as follows:
MODEL
MINIMUM distance (mt) between appliance and ...
ceiling
floor
front
side
UFO EB / 08 and UFO M /08
0,7
2,0
1,0
1,0
NOTE – contact us in case of different distances or special cases
SURFACES CLOSE to APPLIANCES MUST BE DONE IN MATERIAL of
CLASS 'A0' with respect TO FIRE RESPONSE (NOT COMBUSTIBLE and
NOT FLAMMABLE) and with DEGREE of RESISTANCE TO FIRE EQUAL
or MORE THAN "REI 90"