33

Control 485 - with 3rd party (IR) via Fontus

CONTROL 485 WITH 3RD PARTY 

(IR) via FONTUS

IR Input 

NOTE: Refer to the drawings on pg 27-28. See below  

for the IR Fontus pinout. For more details, refer to 

pg 8 of the pdf in the included Fontus instructions. 

Alternatively you can scan the QR code here to access 

the instructions.

(Green) Data (+)

IR Receiver

Input

(Yellow) Data (-)

(Black) Ground

Summary of Contents for Solo / Pro 2

Page 1: ...Solo Pro 2 Installation Instructions 110v AC Motors...

Page 2: ...t cause harmful interference and 2 This device must accept any interference received including that which may cause undesired operation NOTE This equipment has been tested and found to comply with the...

Page 3: ...rs of quality use For a quick install it is recommended you run appropriate wire to the installation location before installing the screen See the Pre Wire sections for details Follow all local electr...

Page 4: ...t Bar 17 AC 110v Rts 18 Programming AC 110v Rts 19 Pairing Another Rf Remote 21 Using Original Remote 21 Programming AC 110v 485 With Decoset Incl 22 Screen With UAI SI FI Block Diagram 25 Control AC...

Page 5: ...l 485 With 3rd Party IR Via Fontus Programming 34 Control 485 Screens With Included Decoset Keypad 36 Control AC 110v 485 With 3rd Party Via IP Controller 37 Control AC 110v 485 With 3rd Party Via DCT...

Page 6: ...4 AC 110v RTS Parts in the Box RF Remote AC 110v RTS Parts in the Box 2 Ceiling Wall Locking brackets 6 Leveling Shims PWR Solo Pro 2 screen 6 Wood fasteners...

Page 7: ...110v 485 Parts in the Box 6 Wood fasteners Additional accessories required for 485 control pg 42 Solo Pro 2 screen 485 PWR 2 Ceiling Wall Locking brackets Decoset Interface Bracket SET UPPER SET LOWE...

Page 8: ...Spacer Blocks are used to clear an obstruction on the wall Connect spacer block to each wall bracket before installation Leveling Shims are used if the ceiling or other mounting surface is out of lev...

Page 9: ...of screen cassette installation location refer to pg 9 To be sure you have the correct wire you can order 485 wire directly from SI 2 Terminate the wires with the provided terminal block as shown bel...

Page 10: ...rovided or other anchors not provided capable of carrying the load that is suitable to the substrate DO NOT MOUNT TO HOLLOW SHEET ROCK 1 The drop is adjustable in the field between 0 and the MAX DROP...

Page 11: ...9 Solo Pro 2 Installation 13 4 View Height Drop Bracket size 3 43 87mm 2 02 51mm 4 88 124mm 3 43 87mm 2 01 51mm 3 78 96mm Medium Large...

Page 12: ...f the cassette to determine the min and max horizontal spacing of the mounts Mark the location of the brackets over a stud or ceiling joist and within an appropriate distance from the ends If the loca...

Page 13: ...ation wire exits back corner of the cassette Cassette Length View Width Brackets secured to Wall or Ceiling Structural Supports Screen Centerline Structural Supports 2 Min to 8 Max pull wire through t...

Page 14: ...rs Make sure the brackets are along the same level line Install the terminal block bracket 485 only next to the left bracket This bracket may be used to hold the power and or controls RJ45 coupler 485...

Page 15: ...the wall bracket lever is down Proper position for installing screen Solo Pro 2 Installation 6 Push the power wire into the pre wire hole Follow local electrical codes when running and terminating AC...

Page 16: ...14 7 Connect the screen RJ45 to the data pre wire RJ45 Using the included coupler press the coupler into the mount Power Data Solo Pro 2 Installation...

Page 17: ...Hang the screen on the mounting brackets ensuring that all hooks are engaged in the channel in the back of the cassette for all the brackets Solo Pro 2 Installation Hanging the screen will require 2 p...

Page 18: ...red viewing location then lock the screen in place rotating the wall bracket lever to the upward position 10 Remove the weight bar screw before deploying screen see red label on the weight bar 11 Use...

Page 19: ...e material just above the middle of the weight bar and lightly pull on the material to smooth out any wrinkles at the weight bar 3 Repeat the process to move the material from the center toward the ot...

Page 20: ...te supplied with the screen controls the opening and closing from up to 30 feet away Enjoy RF controlled projection screens operate at 433 42MHz Minimize or eliminate any sources of RF interference an...

Page 21: ...til the screen jogs once 3 Use the DOWN and UP buttons to position the viewing area vertically up to Max Drop from the bottom of the cassette Setting the Drop Solo Pro 2 is factory preset to have 1 of...

Page 22: ...area is positioned hold the middle square STOP button until the screen jogs once This saves the new lower limit If this Step is not completed the screen will jog once after about 3 minutes indicating...

Page 23: ...ck of the remote until the screen jogs once Holding the new remote briefly press the Program button on the back The screen will jog once The new remote is now paired with the screen A brief press is a...

Page 24: ...area and the cassette The drop can be adjusted up to the MAX DROP see model number or order information for your screen s MAX DROP to customize the viewing surface s vertical position NOTE Refer to p...

Page 25: ...mmissioned via the IP controller web interface Only after fully commisioning your screen should you then use your control system s programming guide to integrate your screen into it Utilizing RJ 45 TI...

Page 26: ...s computer but the steps for programming on a Mac are very similar For a complete guides to program your IP controller on a Mac please visit https www screeninnovations com accessories pa_product cate...

Page 27: ...Supply Data Hub Device Device Device Device Device Stub length must not exceed 200 Data CAT 5e or better To IP Network Standard CAT 5e or higher cable SDN Power c c c c Powe Screen with UAI SIFI block...

Page 28: ...op right corner then click Settings 5 Select the SDN tab on the top left 6 Press the spyglass to auto discover motors on the 485 network may have to press it more than once 7 Click on the motor you wa...

Page 29: ...e Import Discovered devices button Then click Back 7 Name the motor you want to program and click on Accept Then click Back 8 Click on the Config button of the motor you want to program 9 Click on the...

Page 30: ...te To change the programming lower limit you will need either a DecoSet or IP Controller For connection to your control system with an IP Controller refer to pinout image pg 20 Then use your control s...

Page 31: ...29 USING 485 MOTOR INTERFACE WITH FONTUS FOR 3RD PARTY CONTROLS AC MOTORS Screen Coupler Wire run to Head End TS to the Projector V V G 485 Motor Interface 485 Motor only Wire from Screen shade...

Page 32: ...R INTERFACE WITH FONTUS FOR 3RD PARTY CONTROLS LV MOTORS Screen TS to the Projector Screen Power Supply 20m Max Red wire Black wire V V G Wire run to Head End Wire from Screen shade 485 Motor Interfac...

Page 33: ...ructions Alternatively you can scan the QR code here to access the instructions CONTROL 485 WITH 3RD PARTY WET CONTACT via FONTUS Control 485 with 3rd party Wet Contact via Fontus Red 7 28v DC to Powe...

Page 34: ...ctor Dry Contact Closure Input NOTE Refer to the drawings on pg 27 28 See below for the Dry Contact Fontus pinout For more details refer to pg 7 of the pdf in the included Fontus instructions Alternat...

Page 35: ...IR Input NOTE Refer to the drawings on pg 27 28 See below for the IR Fontus pinout For more details refer to pg 8 of the pdf in the included Fontus instructions Alternatively you can scan the QR code...

Page 36: ...TY IR via FONTUS PROGRAMMING Hexcodes Third party IR universal control systems may be used to control the screen and commands may be learned from the SI IR Remote or using these hex codes Note Fontus...

Page 37: ...08a4 0000 006c 0000 000c 0006 011b 0006 011b 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 00bb 0006 011b 0006 011b 0006 08a4 0000 006c 0000 000c 0006 011b 0006 011b 0006 00bb 0006...

Page 38: ...WITH INCLUDED DECOSET KEYPAD Control 485 with 3rd party IR via Fontus Keypad Application NOTE Refer to pgs 17 19 in the included Decoset instructions Alternatively you can scan the QR code here to ac...

Page 39: ...ing with the RS 485 connection Connecting your 3rd party control system to Solo 2 uses an IP network connection Connect your IP Controller to the same IP network as your control system and follow the...

Page 40: ...s through Input Power Data Output Bus Power Supply Data Hub Device Device Device Device Device Stub length must not exceed 200 Data CAT 5e or better To IP Network Standard CAT 5e or higher cable SDN P...

Page 41: ...ontact closure via included DecoSet switch See following block diagram See 485 wiring pinout pg 21 for wiring termination See DecoSet instructions pg 11 to integrate control system dry contact closure...

Page 42: ...40 Relays Control System Screen RS485 Control AC DC Power In Control AC 110v 485 with 3rd party via DCT 485 Motor Interface 485 Motor only...

Page 43: ...41 Mounting Accessories MOUNTING ACCESSORIES purchased separately Zero Gap Wall Brackets De cora Ceiling Brackets De cora Flying Brackets Ceiling Wall Locking Brackets incl standard...

Page 44: ...42 Connect LinkProZ Solo remote TRO Y MOTOR ACCESSORIES AC 110v RTS 485 purchased separately Motor Accessories AC 110v RTS 485...

Page 45: ...k on It is preferred to store or transport your Solo Pro 2 horizontally Shock and vibration experienced during transportation may shift the screen material and cause slight wrinkles Follow the steps b...

Page 46: ...ard the other edge 4 If the screen has been stored in a wrinkled condition The wrinkles may not fall out immediately If wrinkles remain after an hour call 512 832 6939 opt 1 for further instructions S...

Page 47: ...t dirt hair particles and any other foreign material Loose material will cause dimples in viewing and can be carefully brushed away with a microfiber cloth Smudges and splotches from water soluble dir...

Page 48: ...nnection and check breaker box Material has shifted at the weight bar An intermediate stop was set for the motor Gently move the material out to each end of the weight bar until smooth Call SI Custome...

Page 49: ...ove to within 30 ft of Solo Hold remote vertical Turn off other sources of RF Move to position where metal objects wiring or foliage does not block the signal Replace with CR2430 3V lithium button bat...

Page 50: ...ptom Incorrect or poor cable termination IP Controller is not powered Check the wire pinouts and termination Look for broken loose or damaged wires Reterminate if necessary Check that the green LED on...

Page 51: ...le to validate the 485 network and motors are operating properly before troubleshooting IP Controller network problems Check that the IP Controller is communicating on the local network Ping the devic...

Page 52: ...Screen Innovations 9715 B Burnet Rd Suite 400 Austin TX 78758 512 832 6939 www screeninnovations com v 1 6 20 July 2021...