background image

911-404   Rev. J   3/2003

Page: 2 of 2 

A. RO  feed  water  pressure  from  the  pump  is  dependent  upon  restrictions  within  a  particular  RO  filtration  unit.

Nominal booster pump system pressure will be between 75–110 psi.

 [5–7.5 bar].

B. Re-check all water connections for leaks after the RO unit has completely filled the accumulator and the booster

pump shuts off.

C. In  the  event  of  a  power  failure,  the  drinking  water  system  will  operate  on  normal  city  water  pressure.    A  lower

quantity and quality of water may be produced during this period.  Once the power is restored, drain the reservoir
and allow the system to produce new supply of water.

D. The  pump  design  permits  brief  periods  of  dry  operation;  however,  extended  dry  operation  will  decrease  its

performance/longevity.

E. Refer  to  SHURflo  Service  Bulletin

 

#

1052  for  further  information  regarding  RO  Booster  Pump  System,  maintenance,

troubleshooting, and repair.

TECHNICAL SPECIFICATIONS 

SERIES 

85-120

85-121

80-120

80-121

70-121

Feed Water Flow Rate 

(pump output) 

10-18 

GPH

 [38-68 

LPH

]

 @

75-110 psi [5-7.5 bar] 

3-10 

GPH

 [11-38 

LPH

@

75-110 psi [5-7.5 bar] 

5-60 

GPH 

[19-23 

LPH

]

 @

70 psi. [5-7.5] bar 

Voltage 

(Transformer)

 

115

VAC

/24

VDC

 50

VA

, 60Hz 

 

220

VAC

/24

VDC

 50

VA

, 50/60Hz

 

115

VAC

/24

VDC

 20

VA

, 60Hz 

or 

220

VAC

/24

VDC

 20

VA

, 60Hz 

 

Inlet Water 

Regulator 

Regulates large variations in inlet pressure to 

12–15psi. [0.8–1 bar] dynamic 

Not affected 

by inlet pressure 

Fittings 

John Guest

® 

Quick Connect fittings Inlet & Outlet 

(

1

/

4

" or

 

3

/

8

" available)

 

1

/

4

John Guest

®

 

Tank Switch 

(Full Tank Shut-off)

 

Controls pump / switch opens (pump off) at 40 ± 2 psi.[2.7 ± 0.13 bar], 

closes (pump on) at 25 ± 5  psi [1.7 ± 0.27 bar]. 

Pump Design 

Three chamber diaphragm pump with 80 psi. [5.4 bar] internal bypass 

 With replaceable fuse 

 With internal, non-replaceable fuse.

 When used with RO filtration units that produce up to 35 GPD

 [132 LPD].

 

 Dependent upon RO restrictions and membrane

SHURflo RO BOOSTER PUMP SYSTEM LIMITED WARRANTY 

SHURflo warrants the 85-120 & 85-121 series to be free of defects in material and workmanship under normal use, 
for one (1) year, with proof of purchase.  This limited warranty will not exceed eighteen (18) months from the date 
of manufacture, in any event. 

SHURflo  warrants  the  70-121,  80-120  &  80-121  series  to  be  free  of  defects  in  material  and  workmanship  under 
normal use, for two (2) years, with proof of purchase.  This limited warranty will not exceed thirty (30) months from 
the date of manufacture, in any event. 

The limited warranty will not apply to Booster Pump Systems that were improperly installed, misapplied, damaged, 
altered, or incompatible with components not manufactured by SHURflo.   

All  SHURflo  Booster Pumps Systems should be returned to freight prepaid to the Authorized SHURflo Distributor 
where  originally  purchased.    SHURflo  shall  not  be  liable  for  freight  damage  incurred  during  shipping,  package 
returns carefully. 

For complete Water Products Limited Warranty details consult Service Bulletin 

#

1053 

 

ISO Certified Facility

R

a WICOR Company

SHURflo reserves the right to update specifications, prices, or make substitutions. 

SHURflo 

 

P: 1-800-942-1153 
F: 1-800-942-0081 