background image

 
 

 

 
 
 
 
 
 

Specifications

 

Voltage

 

     

10 - 14 Volt DC 

Maximum Amps

 

5 Amps  Use 6-Amp Fuse 

Hole Size

 

 

14” x 14” Standard  
[13.75” to 14.25” square] 

Roof Thickness 

 

 

 

2” to 3-1/2” 

Trim # 21-1613-00 

3-1/2” to 5-1/4” 

Trim # 21-1613-01 [Standard] 

5” to 6-1/4” 

Trim # 21-1613-02 

Maximum CFM 

Intake 

 

  920 CFM 

Exhaust

   

1055 CFM 

Thermostat Range

 

60°F to 100°F  

Remote Control 

Model 84-940-xx 

Remote Battery

 

9 Volt DC  

Dimensions

    

17” x 17” x 4-1/4” 

closed

 

 

 

 

17” x 17” x 12-1/2” 

open

 

Materials

     

UV resistant ABS and 
Polycarbonate 

Wire

   

 

12” Red (+) Black (-) 18 AWG 

 

                   

SHURflo reserves the right to update specifications, prices, or make substitutions 

 

SHURflo 

«

 

5900A Katella Ave. 
Cypress, CA 90630 

(800) 854-3218 
(562) 795-5200 

FAX  (562) 795-7564 

 
 

 

SHURflo East 

52748 Park Six Court 

Elkhart, IN  46514-5427 

(800) 762-8094 
(574) 262-0478 

FAX  (574) 264-2169 

www.shurflo.com 

© 2004 All Rights Reserved 

SHURflo Ltd.  

Unit 5  Sterling Park 

Gatwick Road, Crawley 

West Sussex, RH10 2QT 

United Kingdom 

+44 1293 424000 

FAX  +44 1293 421880 

 

 

 

ê

ISO certified facility 

 

 

**ISO certified facility 
 
 
 

** 

Limited Warranty Information 

SHURflo Pump Manufacturing Co. (SHURflo) warrants this product to be free from defects in material or workmanship to the original owner for personal or family use, for a 
period of 2 years,

 5 years warranty on exterior Dome and Screen

 from original date purchase. This product is warranted for 90 days from original date of purchase when used 

for commercial or business application. The warranty may provide for repair, including labor or exchange or replacement of unit, or parts as necessary. 
 
An owner having a part or unit believed to be defective should contact a local RV dealer, or contact the nearest SHURflo office. 
SHURflo will not accept the return of parts or units, will not send out parts or units or allow for the repair or replacement of parts or units under this warranty without giving 
their prior expressed authorization and without proof of date of purchase. 
If SHURflo finds the unit or part to be defective and is the subject of a valid warranty claim, SHURflo will pay the dealer a labor allowance and supply repair part(s) or a 
replacement unit as applicable. 
This warranty does not extend to parts or units which if, in the judgment of SHURflo, have been damaged or rendered defective by misuse, negligence, accident, improper 
installation, unreasonable use or if the unit or part has been tampered with or altered in any manner.  
In no event, whether as a result of breach of contract, tort (including negligence) or otherwise, shall SHURflo be liable to any owner of a unit for any special damages arising 
out of the use, or inability to use that unit, nor for any claim against the owner by another party.  Some states and provinces do not allow limitations on how long an implied 
warranty shall last or do not allow the exclusion or limitation of incidental or consequential damages.  So the above limitation or exclusion may not apply to you.   
This warranty gives you specific legal rights, and you may also have other rights that may vary from state to state. 

 

FCC Statement 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.  These limits are 
designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate 
radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  
However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or 
more of the following measures: 

• 

Reorient or relocate the receiving antenna 

• 

Increase the separation between the equipment and the receiver 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

• 

Consult the dealer or an experienced radio/TV technician for help. 

In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment.  Operation with non-approved equipment or 
unshielded cables is likely to result in interference to radio and TV reception.  The user is cautioned that changes and modifications made to the 
equipment without the approval of the manufacturer could void the user’s authority to operate this equipment. 
 
Operation is subject to the following two conditions: 

(1)  this device may not cause interference, and 
(2)  this device must accept any interference, including interference that may cause undesired operation of the device. 

Troubleshooting

 

 

PROBLEM 

POSSIBLE SOLUTIONS 

Fan remote does not work 

Check main power, fuse and 

battery.  Reset remote. 

Fan & dome buttons do not work 

with fan off and dome closed 

Unit in Auto Mode: press Fan Off 

to exit Auto Mode 

 
 

Unit shuts off and closes 

Preset temperature reached in 

Auto Mode, Rain sensor 

activated: Adjust Thermostat to 

turn fan on. Press fan Off to exit 

Auto Mode. 

 

Dome will not open or close, but 

dome motor is running 

Push hand crank up to actuate 

dome motor gears. 

Dome motor will turn off after 3 to 

5 minutes if gear is not engaged. 

Dome starts to open or close and 

then stops. 

If motor continues to run: 

Dome hitting object.  Check 

dome path for obstruction. 

Push up crank gear to engage. 

 
 

911-724-A  04/05 

 

 

 

 

 

 

 

 

 

 

 

 

page 4 of 4

Summary of Contents for Comfort Air 275-3330

Page 1: ... 9 Volt DC Remote Control Battery 1 Installation and Operation Manual Location Fan must be installed with the hinge facing the direction of travel Locate bi directional fan at least 3 feet from any exhaust vent l Do not install fan in cooking area Important Information SHURflo recommends professional installation Please read the entire manual before attempting installation This unit requires 12 VD...

Page 2: ...ermostat temperature setting sBattery Compartment Rear of Remote Slide open rear compartment to replace 9V battery Resetting The Remote Never reset remote control with screen removed It may be necessary at times to reset the remote to match the Comfort Air unit This would be done to make one remote work for 2 fans to make 2 fans operate from different remotes or when purchasing a new remote for an...

Page 3: ... of Fan Operation HAND DOME OPERATION Pull down on manual crank and turn to open or close the dome by hand Push crank up to lock gears for power dome operation MANUAL MODE Press Fan Hi 1 or Fan Lo 3 buttons or Dome Open 4 Stop 5 or Close 6 buttons to operate in Manual Mode Changing Fan Direction Press Exhaust Intake button 7 to change direction AUTO MODE Press Cooler button 8 or Warmer button 9 on...

Page 4: ...owner by another party Some states and provinces do not allow limitations on how long an implied warranty shall last or do not allow the exclusion or limitation of incidental or consequential damages So the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and youmay also have other rights that may vary from state to state FCC Statement This equipment...

Reviews: