background image

2. 

DESCRIPTION 

The SHURflo BRIX proportioning pump is driven by pressurized water, allowing the water and product to 
be delivered at an exact ratio.  The pump operates whenever there is a differential in pressure between 
the inlet and outlet watersides of the pump.  The  design incorporates large "duck bill" style valves that 
easily allow concentrates with pulp or particulates to flow through.  When your customers demand a 
quality drink, you are assured that SHURflo technology will deliver accurate repeatable brix without the 
need for expensive metering devices. 

 

MODEL OPTIONS 

The BRIX pump is offered in two basic configurations, with or without a vacuum shut-off.  The last two 
numbers of the model indicate the use (-02), or deletion (-01) of the shut-off.  The type of concentrate 
container being used determines if the shut-off should be applied. 

When a Bag-in-Box (B-I-B) container is used, a vacuum shut-off is needed.  The pump will automatically 
stop operation, when the concentrate bag is completely evacuated, by closing off the inlet water.  When a 
new B-I-B is installed, the pump will automatically resume operation without the need to prime the 
system.  BRIX pumps without a vacuum shut-off option should be used with rigid sided containers like 
tanks or jugs.  Containers of this type 

must

 be vented. 

 

 

Dashed lines indicate position of vacuum shut-off when ordered. 

 

The BRIX pump is available in exact ratios, which properly proportion various concentrate types.  Pump 
ratios are indicated on the part number label.  The ratio of a pump is preset and is not adjustable in any 
way.  

 

DISPENSER CONFIGURATION 

The dispenser valve is an important component to the BRIX pump system and contributes heavily to the 
final performance.  When developing the system, the type of dispenser depends on the customers 
requirements, concentrate properties, backpressure created within the lines, and the dispensers ability to 
flow.  A BRIX pump is designed to deliver to one dispenser valve at a time.  If other valves are on line, it is 
acceptable only when a lockout device prevents simultaneous operation.  Depending on the system 
design and the concentrate, finished drink flow rates are generally 1½ - 3 ounce [45-90 cc] per second. 
 

Summary of Contents for Brix 94-260-01

Page 1: ...f the proportioned liquids typically the incoming water eliminating the need for CO2 or electric power The Brix pump is designed with a vacuum shut off The vacuum shut off will automatically stop operation of the brix pump when the concentrate BIB container is completely evacuated by closing off the water inlet When a new BIB is installed the pump will automatically resume operation without the ne...

Page 2: ...e POWER SOURCE Potable Water MATERIALS OF CONSTRUCTION Acetal Copolymer EPDM Santoprene Silicone 316 Stainless Steel FDA sanctioned NSF listed TEMPERATURE LIMITS 34 120 F 2 45 C DIMENSIONS 7 6 x 5 2 x 5 7 19 3 x 13 2 x 14 47 cm WEIGHT 2 2 lbs 1 kgs OPERATING PRESSURE 50 PSI 3 4 bar MAX 25 PSI 1 7 bar MIN ACCURACY 3 of available ratio SOLD OUT Automatic B I B Vacuum Shut off 18 22 in Hg 48 61 kPa A...

Page 3: ... years of experience in pump technology to provide a safe and reliable proportioning pump Every SHURflo pump is 100 tested for proper flow pressure and performance before it leaves the factory Although this tested design will provide years of trouble free and economical operation you should use care in installing your system ...

Page 4: ...vacuated by closing off the inlet water When a new B I B is installed the pump will automatically resume operation without the need to prime the system BRIX pumps without a vacuum shut off option should be used with rigid sided containers like tanks or jugs Containers of this type must be vented Dashed lines indicate position of vacuum shut off when ordered The BRIX pump is available in exact rati...

Page 5: ... damage to the pump may occur When multiple concentrates are plumbed to a post mix dispenser each pump s water outlet must have an individual line valve to open when that flavor is selected Bar Guns generally are restrictive therefore it is recommended that special Juice Guns be used Concentrate passages of standard bar guns are small and may become plugged with pulp or solids contained in some co...

Page 6: ...ber in line prior to the dispenser The single line run lengths should be minimal to reduce backpressure Backpressure within teed outlet line should not exceed 32 psi 2 0 bar Pre mix valves with minimal full flow backpressure are commonly used with this type of configuration Teed systems should have a one way check valve plumbed after the concentrate outlet and before teeing into the water outlet l...

Page 7: ...ich are highly viscous and or contain solids may be packaged with a connection that uses a less restrictive Q C D and 1 2 13mm I D tubing The length of tubing and vertical lift that a BRIX pump can accommodate at the concentrate inlet is dependent on the particular characteristics of the product Also colder concentrate temperatures adversely affect the systems inlet side due to the increase in vis...

Page 8: ...line and plumb to the Sanitize port as shown on pages 2 or 3 Always use NSF listed high pressure braid tubing 3 8 or 1 2 10 or 13mm I D for pressurized lines and secure all connections with stainless steel inserted Oetiker clamps Tie wrap all tubing securely to prevent kinks and relieve stress on pump fittings Although it is recommended that line lengths are kept to a minimum it is a good idea to ...

Page 9: ...tion 5 25 or equivalent 3 Clean five 5 gallon U S 19 liter bucket 4 Measuring cup 5 An adapter is needed to hold the Q C D fitting on the concentrate suction line open A connector cut from an empty bag will work SANITIZING PROCEDURE 1 Fill the bucket with four 4 gallons 15 14 l of warm water 120 180 F 48 82 C 2 Measure four 4 ounces cup 118cc of the liquid detergent and add to the water 3 Measure ...

Page 10: ...e when the bags where filled Stand the box up on end and pull the connector up allowing air to rise up to the bag connector Install a Q C D and engage it on the bag connector opening the passage Slowly press the Q C D back down expelling the air until concentrate appears release the Q C D closing the connector This is referred to as burping the bag Pump stroke should be even time in both direction...

Page 11: ...or for information Complete instructions are included with each kit 3 Reassemble each cartridge so that the valve support is not holding the valve open Lubricate the serrated surface of the valves and o rings with an NSF listed food grade lubricant Reinsert the appropriate valves into the housing turn back into position and tighten the screw Be aware that the valves may turn allowing the support t...

Page 12: ...moved see SHURflo Service Bulletin 1046 Pumps that are returned to SHURflo that are not sanitized flushed will be dispositioned as a scrapped pump and will not be considered for testing repair or recondition When BRIX pumps are being returned to a service center please contact the appropriate location prior to shipment to initiate a Return Goods Authorization SHURflo manufactures the BRIX pump com...

Page 13: ...Rflo East Elkhart IN or West Coast facility Cypress CA Package all returns carefully SHURflo will not be responsible for freight damage incurred during shipping to a service center Upon receiving a pump it will be tested per SHURflo s test criteria SHURflo s obligation under this warranty policy is limited to the repair or replacement whichever it deems advisable of the unit Pumps found not defect...

Page 14: ...b Plastic 90 configuration AVAILABLE FITTINGS 1 4 6mm 3 8 10mm and 1 2 13mm barb Plastic or Stainless Steel Straight and or 90 configurations MODEL NUMBER MATRIX 5000 2XX 01 without shut off Model ratio 02 with shut off AVAILABLE RATIOS 3 00 1 30 Red dot 4 00 1 40 Blue dot 4 20 1 42 5 00 1 50 Yellow dot 5 30 1 53 6 00 1 60 Other ratios available contact the factory for specific applications ISO Ce...

Reviews: