background image

Input Port Isolation

50 dB, typical

RF Input Power

Operating Range, Per Channel

4.5 to 15 dBm

LED Indicator Minimum Detection Threshold

3 dBm±1.5 dB

RF Overload LED Threshold

17.5 dBm±1 dB

Impedance

50 Ω

RF Output

RF Frequency Range

470 to 865 MHz

Output Intercept Point (OIP3)

48 dBm, typical

Connector Type

BNC

Impedance

50 Ω

Reverse Isolation

Ouput to Input

40 dB, typical

Gain

Input to any output port

−5 to 0 dB

LICENSING INFORMATION

Licensing: A ministerial license to operate this equipment may be required
in certain areas. Consult your national authority for possible requirements.
Changes or modifications not expressly approved by Shure Incorporated
could void your authority to operate the equipment. Licensing of Shure wire-
less microphone equipment is the user’s responsibility, and licensability de-
pends on the user’s classification and application, and on the selected fre-
quency. Shure strongly urges the user to contact the appropriate telecommu-
nications authority concerning proper licensing, and before choosing and
ordering frequencies.

This device complies with Industry Canada licence-exempt RSS standard(s).
Operation of this device is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any inter-
ference, including interference that may cause undesired operation of the
device.

Le présent appareil est conforme aux CNR d'Industrie Canada applicables
aux appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2)
l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.

Federal Communications Commission RF Exposure Notice:

Antennas used for the purpose of radiating signals are limited to a maximum
gain of 14 dBi. Each antenna must be positioned to observe minimum sepa-
ration requirements from all users and bystanders. The following guidelines
should be used when considering separation distances.

Antennas must be placed such that, under normal conditions, personnel
cannot come within 72 cm (~2.5 ft.) from any antenna. Adhering to this mini-
mum separation will ensure that the employee or bystander cannot exceed
RF exposures beyond the maximum permissible limit as defined by 47 CFR
1.1310, i.e., limits for General Population/Uncontrolled Exposure.

Certifications

Meets essential requirements of the following European Directives:

Low Voltage Directive 2006/95/EC

Conforms to the relevant requirements of regulation (EC) No.278/2009, for
low voltage external power supplies.

R&TTE Directive 99/5/EC

Conforms to European Regulation (EC) No. 1275/2008, as amended.

WEEE Directive 2002/96/EC, as amended by 2008/34/EC

RoHS Directive 2011/65/EU

Note:

Please follow your regional recycling scheme for batteries and

electronic waste

Meets requirements of the following standards:

Certified under FCC Part 74.

Certified by IC in Canada under RSS-123 and RSS-102.

FCC ID:

DD4PA411A.

IC:

616A-PA411A.

The CE Declaration of Conformity can be obtained from Shure Incorporated
or any of its European representatives. For contact information please visit
www.shure.com

The CE Declaration of Conformity can be obtained from:

www.shure.com/europe/compliance

Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: +49-7262-92 49 0
Fax: +49-7262-92 49 11 4
Email: [email protected]

Shure Incorporated

PA411

 Antenna Combiner

4/4

Shure Incorporated 5800 West Touhy Avenue Niles, IL 60714-4608 USA Phone: +1-847-600-2000 Email: [email protected]

Summary of Contents for PA411

Page 1: ...S socket outlet with a protective earthing connection 19 To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 20 Do not attempt to modify this product Doing so could result in personal injury and or product failure 21 Operate this product within its specified operating temperature range WARNING This product contains a chemical known to the State of Californ...

Page 2: ...470 865 MHz RF LED Indicators Green RF signal present Red RF signal overload Power LED Green Power on Green red flashing Power output overload Power Switch Power Input Requires a Shure PS60 power supply Power Output Requires a Shure PS411 PC power distribution cable to deliver power to transmitters RF Inputs Connect to transmitter RF outputs Power and RF Connections 1 Connect the Shure PS60 power ...

Page 3: ...UA8 554 638 1 2 wave antenna 554 638 MHz UA8 578 638 1 2 wave antenna 578 638 MHz UA8 596 668 1 2 wave antenna 596 668 MHz UA8 596 698 1 2 wave antenna 596 698 MHz UA8 596 714 1 2 wave antenna 596 714 MHz UA8 600 666 1 2 wave antenna 600 666 MHz UA8 626 698 1 2 wave antenna 626 698 MHz UA8 638 698 1 2 wave antenna 638 698 MHz UA8 670 742 1 2 wave antenna 670 742 MHz UA8 710 790 1 2 wave antenna 71...

Page 4: ...ral Communications Commission RF Exposure Notice Antennas used for the purpose of radiating signals are limited to a maximum gain of 14 dBi Each antenna must be positioned to observe minimum sepa ration requirements from all users and bystanders The following guidelines should be used when considering separation distances Antennas must be placed such that under normal conditions personnel cannot c...

Reviews: