Labels

“Lightning Flash Symbol” with the lightning flash with arrowhead symbol within an equilateral

 

triangle, is intended to alert the user to the presence of un-insulated "dangerous voltage" with-

in the product enclosure that may be of sufficient magnitude to constitute a risk of shock to 

persons.

“Exclamation Point Symbol” with the exclamation point within an equilateral triangle is intend-

ed to alert the user to the presence of important operating and maintenance (servicing) in-

structions in the literature accompanying the product.

Note for Power Connections

Check that the voltage of your local power supply is within the operating voltage of the unit. If a voltage conversion 

is required, consult your DIS dealer or qualified personnel.

Set the Power switch to ‘Off’ if it is not used for several days.

Important:

 The equipment must be connected to earth (ground)

The wires in the main lead supplied with the equipment are colored in accordance with the following codes:

Green-and-yellow Earth (Ground)

Blue Neutral

Brown Live

The green-and-yellow wire must be connected to the terminal in the plug marked with the letter E or with the 

safety earth symbol or marked with green-and-yellow color.

The blue wire must be connected to the terminal marked with the letter N or marked with black color.

The brown wire must be connected to the terminal marked with the letter L or marked with red color.

For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible.

Power Disconnect

Apparatuses with or without On/Off switches have power supplied to the apparatus whenever the power cord is in-

serted into the power source; however, the apparatus is operational only when the On/Off switch is in the On posi-

tion. The power cord is the main power disconnect for all apparatuses.

Compliance

The equipment is intended to be used in professional audio applications.

Note: 

This device is not intended to be connected directly to a public internet network.

EMC conformance to Environment E2: Commercial and Light Industrial. Testing is based on the use of supplied 

and recommended cable types. The use of other than shielded (screened) cable types may degrade EMC perfor-

mance.

Summary of Contents for BM 6620

Page 1: ...tallation or any area which is classified as a wet location 6 Warning To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture and no objects filled with liquids s...

Page 2: ...is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 18 Replacement Parts When...

Page 3: ...rth Ground Blue Neutral Brown Live The green and yellow wire must be connected to the terminal in the plug marked with the letter E or with the safety earth symbol or marked with green and yellow colo...

Page 4: ...o try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipme...

Page 5: ...protects the microphone from RF interference Features Boundary microphone for custom fit flush mounted conference units Low profile omnidirectional condenser boundary microphone with 360 pickup angle...

Page 6: ...Shure Incorporated 6 12 Step 2 Remove the XLR Step 3 Turn over the XLR Undo and remove the two T8 torx screws and the 3mm Allen bolt...

Page 7: ...Shure Incorporated 7 12 Step 4 Separate the connector section from the XLR chassis Step 5 Remove the plastic lock insert...

Page 8: ...Shure Incorporated 8 12 Step 6 Put the XLR chassis back onto the front plate Step 7 Fasten the XLR chassis to the front plate with the 3 M3 nuts...

Page 9: ...mic s rubber sleeve to expand into the XLR chassis and hold it in place Connect the boundary mic to the PCB Specifications Electrical Transducer Type Permanently polarized Electret Condenser Polar Pa...

Page 10: ...Mounting Type Fixed in DIS DCS 6000 flush mounted units Dimensions L x Dia 181 5 x 19 mm Net Weight 63 g 2 22 oz Housing Black Dimensions Cabling Cat5e The DCS 6000 system uses Cat5e or higher FTP or...

Page 11: ...ion Connector 1 Connector 2 1 In going ORG WHT ORG WHT 2 In going ORG ORG 3 48V GRN WHT GRN WHT 4 0V BLU BLU 5 0V BLU WHT BLU WHT 6 48V GRN GRN 7 Outgoing BRN WHT BRN WHT 8 Outgoing BRN BRN Note If ot...

Page 12: ...e and not in cable plugs Cat6 and Cat7 can only be used for longer cable draws terminating in wall outlets or patch panels Analog out XLR3 male Pin Signal Cable type 1 Ground 2 x 0 25 mm shielded 2 In...

Reviews: