background image

4. Use the arrow keys to move the ► to select

OK

to save or

Cancel

to

discard, and then press the

SET

key.

IP Address Mode:

Manual

Use manual IP addressing to set the IP address and subnet mask when a
DHCP server is not available.

1. Navigate to the IP mode menu and press the

SET

key.

2. Use the arrow keys to highlight

Manual

.

3. Press the

SET

key to enable editing of the IP address and the subnet

mask.

4. Use the arrow keys to move the ► to select

IP:

or

Sub:

5. Use the arrow keys and the

SET

key to edit the IP address and subnet

mask.

6. Use the arrow keys to move the ► to select

OK

to save or

Cancel

to

discard, and then press the

SET

key.

MAC

(MAC Address)

Displays the MAC address, which is an embedded, uneditable identification
number unique to each device. Used by the network and WWB software to
identify components.

Display Invert

This changes the LCD menu from white text on dark background to dark text
on a light background.

Firmware

Displays the version of firmware installed on this device.

Fan

(Cooling Fan Mode)

Automatic

The fan is enabled and adjusts speed based on the internal temperature of
the unit.

Always on

The fan runs continuously at maximum speed to provide maximum cooling
in warm environments.

Serial Number

Displays the serial number.

Brightness

Sets the brightness of the LCD to low, medium, or high.

Storage Mode

OFF

Normal charge.

Store at 3.8 V

Charges or discharges all batteries to bring them to a 3.8 volts, ideal for long
term storage.

Troubleshooting

Battery is inserted incorrectly or battery cannot
accept a charge. Check battery temperature.

Charge status LED does not
illuminate.

Battery discharged below 3.0 volts. Try another
battery.

Battery does not charge

Service Fans Maintenance Message

The charger displays the

Service Fans

message when the fans are unable

to cool efficiently.

Press any key to suppress the message for 20 seconds.

Service the fans or increase ventilation to the unit to clear the message.

Ÿ

Ÿ

SET

Service

Fans

Firmware Updates

Firmware is embedded software in each component that controls functional-
ity. Periodically, new versions of firmware are developed to incorporate addi-
tional features and enhancements. To take advantage of design improve-

ments, new versions of the firmware can be uploaded and installed using
the Firmware Update Manager tool available in WWB6 software. Firmware
is available for download from .

Specifications

Battery Type

Up to 8 rechargeable Li-Ion batteries (AXT910/920/920SL)

Charge Time

50%=1 hour; 100%=3 hours

Charging Module Type

Up to 4 charging modules (AXT901 or AXT902) in any combination

Operating Temperature Range

-18°C (0°F) to 63°C (145°F)

Battery Charging Temperature Range

0°C (32°F) to 60°C (140°F)

Shure Incorporated

AXT900

 Rack Mount Charging Station

5/7

2017/10/10

Summary of Contents for AXT900

Page 1: ...ry health using charging cycle count and percentage of original capacity as metrics Charges batteries to 50 capacity within 1 hour Charges batteries to full capacity in 3 hours Simple 3 button interfa...

Page 2: ...te the voltage state Red flashing battery charging or discharging to 3 8 volts Amber flashing battery voltage at 3 8 volts The following indicators appear on the home screen next to each bay number ba...

Page 3: ...e SET key to enter the selected menu item 3 Use the arrow keys to change a menu parameter 4 Press SET to save the setting SET Press and hold both arrow keys to enter or exit the Utility menu Tip Press...

Page 4: ...cle Charge Status Displays charge as a percentage of the total battery capacity Also displays charge in milliampere hours mAh Batt Temp Battery Temperature Displays both the battery temperature in Cel...

Page 5: ...rightness of the LCD to low medium or high Storage Mode OFF Normal charge Store at 3 8 V Charges or discharges all batteries to bring them to a 3 8 volts ideal for long term storage Troubleshooting Ba...

Page 6: ...etween the equipment and the receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician fo...

Page 7: ...h If swallowed contact your physician or local poison control center Do not short circuit may cause burns or catch fire Do not charge or use battery packs other than Shure rechargeable bat teries Disp...