Shure Incorporated
15/23
1.
2.
1.
2.
3.
Turning Off Frequency 2 (Freq 2)
If a problem develops with one of the frequencies being used by the transmitter, you can lock on to a single frequency by turn
ing off frequency 2. Turning off one frequency allows the transmitter to continue passing audio while a clear frequency can be
found for the second channel.
From the Radio menu navigate to
F2 Ctrl
.
Use the controls to set F2 to On or Off. When set to On, the transmitter will pass audio using
Freq 2
.
Input Overload
The OVERLOAD
message appears when the audio input experiences a highlevel signal. The power LED turns red as an addi
tional indicator of an overload. Reduce the input signal or enable the input pad to remove the overload condition.
Tip: To enable the input pad, navigate to
Audio
>
Pad
and select
12 dB
.
Tone Generator
The transmitter contains an internal tone generator that produces a continuous audio signal. The tone is helpful when conduct
ing a sound check or for troubleshooting the audio signal chain. The level of the tone is adjustable from -60 dB to 0 dB and the
frequency can be set to 400 Hz or 1000 Hz.
Always start with the level set to -60 dB to avoid overloading speakers or headphones.
From the Audio menu select
Tone Gen
.
Set the frequency to
400 Hz
or
1000 Hz
.
Select Level and use the arrow buttons adjust the value between -60 dB and 0 dB.
Turn off the tone by selecting Off from the menu or by cycling the transmitter power.