SMART2™ 

L

ite

ALL™ module has been specifically designed 

for use with Shur-Co's exclusive SMART2™ wireless remote. 

Module  has  two  outputs  which  operate  independently  using 

integrated push buttons and has option of linking two outputs 

when controlled via SMART2™ remote.

Utilizing optional output splitters, up to four high-intensity Shur-

Co

®

  LED  work  lights  can  be  connected  to  each  output. Also 

available  are  output  extension  cables,  conveniently  allowing 

high-intensity LED work lights to be mounted where needed. 

SMART2™  LiteALL™  is  a  valuable  addition  to  Shur-Co's 

SMARTrailer™ lineup.

•  SMART2™ LiteALL™ control module has two output chan

-

nels which can be controlled independently or together in 

linked mode using integrated push buttons

.

 

•  Output splitters are available, allowing up to four high-inten

-

sity LED work lights to be connected to each output.

 

 

•  Extension  cables  are  available,  allowing  convenient  and 

useful mounting options for work lights and other devices.

 

•  Control module is quick and easy to introduce to an ad

-

ditional SMART2™ remote.

•  Use your SMART2™ remote to control multiple SMART2™ 

LiteALL™ modules. You can assign custom names to each 

module and to both outputs on each module.

SMART2™ LiteALL™ Features & Operation

control

 

module

output

 B 

Button

output

 A 

Button

output

 

device

 

A

 

(

led

 

work

 

light

 

or

 

other

 

low

 

current

 

device

)

output

 A 

connector

output

 B 

connector

 

(

output

 

splitters

 

Are

 

AvAilABle

output

 

device

 

B

 

(

led

 

work

 

light

 

or

 

other

 

low

 

current

 

device

)

  SMART2™ LITEALL™ OPERATION

•  When SMART2™ LiteALL™ module is connected to 12-volt 

power source, outputs can be turned on manually or with a 

paired SMART2™ remote.

•  To manually control module, simply press OUTPUT A button 

on module to toggle device(s) connected to OUTPUT A chan

-

nel. Press OUTPUT B button on module to toggle device(s) 

connected to OUTPUT B channel.

•  To remotely control LiteALL™ module after it has been intro

-

duced to SMART2™ remote, select LiteALL™ module from 

main menu on remote screen. Refer to section on program-

ming remote to control module for more information.

  Press left operational button directly beneath remote screen 

to toggle device(s) connected to OUTPUT A on and off. Press 

right  operational  button  directly  beneath  remote  screen  to 

toggle device(s) connected to OUPUT B on and off.

  Linked Output Mode:

  Press either operational button directly under remote screen 

to simultaneously toggle both outputs on or off. See section on 

setting operating mode for more information.

Specifications

•  System voltage: 

10 to 16 volts DC

•  System current: 

8 amps maximum per chan-   

 

nel (four Shur-Co

®

 LED work   

 

lights per channel)

•  Reverse polarity protection:  Yes

•  Work light output: 

1600 lumens

•  Work light power: 

24 watts

•  Work light IP rating: 

IP67

•  Work light life: 

30,000 hours estimated

optionAl

 

smArtwire

™ 

AdApter

to

 

smArtwire

™ 

junction

 

Block

power

 

cABle

Summary of Contents for LITEALL SMART2 Remote

Page 1: ...P N 1127747 Rev A SMART2 Remote ...

Page 2: ... the product returned is found in our judgement to be non warrantable the owner will be contacted to authorize repair work purchase of a replacement product or return of the product all of which will be at the owner s expense Payment authorization must be received by us before any non warrantable product is repaired replaced or returned All expenses associated with deliver ing the repaired non war...

Page 3: ... CALL OUR HELP LINE 1 866 748 7435 MON FRI 8 AM 5 PM CENTRAL TIME SMART2 LiteALL Features Operation 1 SMART2 LiteALL System Components 2 LiteALL Control Module Installation 3 4 LiteALL Work Light Installation 5 6 Programming SMART2 Remote to Control Module 7 8 Setting Operating Mode 8 9 Renaming Control Module Outputs 10 Electric Wiring Wiring Diagrams 11 12 We at Shur Co are concerned with your s...

Page 4: ... work light or other low current device output A connector output B connector output splitters are available output device B led work light or other low current device SMART2 LITEALL OPERATION When SMART2 LiteALL module is connected to 12 volt power source outputs can be turned on manually or with a paired SMART2 remote To manually control module simply press OUTPUT A button on module to toggle de...

Page 5: ...ommet 7 16 x 15 16 N 1703282 Rubber Grommet 7 8 x 1 5 8 P 1703282 Rubber Grommet 7 8 x 1 5 8 P 1706007 Hex Head Self Drilling Screw 12 x 1 1 2 qty 4 K 1704405 Pan Hd Self Drilling Screw 8 x 3 4 qty 6 J 1122690 SMARTwire Power Cable Adapter w WeatherPack Connector 1122705 LiteALL Output Splitter w WeatherPack Connector A B 1122108 SMART2 Remote Kit SMART2 Transmitter w Charging Cradle 1704958 SMART...

Page 6: ... Clip 5 16 Natural P Rubber Grommet 7 8 x 1 5 8 liteall control module cutouts liteall control module NOTE Keep in mind that power cable on module is 8 long and must be connected to 12 volts K power cable output cables cut 1 1 4 hole liteall control module power cable output cables P STEP 3 If power and or output cables are NOT being routed through mounting surface route through cutouts in bottom ...

Page 7: ... wire L Connect LiteALL power cable to SMARTwire adapter cable POWER SUPPLIED FROM SMARTWIRE CONNECTION POWER SUPPLIED VIA OTHER MEANS White wire is positive Connect white wire to positive 12 volt Black wire is negative Connect black wire to negative post Do not leave power connections exposed to elements If needed optional sealed junction box kit W is available Plug adapter cable into junction bl...

Page 8: ... cut hole for grommet P Thread work light cable through grommet then insert grommet into hole shown assembled work light cable 1 1 4 hole P NOTE IfWeatherPackpinremovaltool DelphiP N12014012 is available smaller grommet can be used Remove plastic connector from pins drill 11 16 hole pass pins through grommet and drilled hole then re attach plastic connector B side to black wire and insert grommet ...

Page 9: ...nd work light cables NOTE If needed 20 extension cables are available see parts list J work light cable M STEP 7 Repeat steps above for each additional work light If more than one work light is to be connected to either LiteALL module output insert output splitter E E liteall module output work light cables CAUTION Disconnect LiteAll before welding onto truck or trailer Failure to disconnect modul...

Page 10: ...PPER BACK HOPPER NEW DEVICE BACK TO SETUP WAITING HOLD BUTTON ON TARGET RECEIVER FOR 5 SECONDS TO PAIR DEVICE FIGURE 3 STEP 4 Remotewillnowbewaitingforreceivertoenterpairing mode FIGURE 2 STEP 3 Arrow to Add Device and press Select SETUP MENU TO MAIN MENU DEFAULT DEVICE DEVICE ORDER ADD DEVICE EDIT DEVICE DELETE DEVICE INFORMATION STEP 1 Make sure LiteALL control module is connected to power STEP ...

Page 11: ... if desired If you choose to rename at this time see section on renaming device in your SMART2 remote Owner s Manual If current name is accept able highlight Accept and press Select to continue FIGURE 6 CHANGE NAME LGHT0000008E ACCEPT CANCEL ABCDEFGHIJKLM NOPQRSTUVWXYZ 0123456789 _ STEP 1 From main menu on SMART2 remote arrow to Setup option and press Select STEP 2 Arrow to Edit Device and press S...

Page 12: ...emote will confirm that mode has been changed Press Select to finish EDIT DEVICE BACK TO SETUP TARP FRONT HOPPER BACK HOPPER LIGHTS FIGURE 9 FIGURE 10 EDIT DEVICE LIGHT BACK TO SETUP CHANGE NAME NAME OUTPUTS DEFAULT MODE SET TO LEARN DELETE DEVICE FIGURE 11 FIGURE 12 MODE CHANGED SELECT CONTINUE LINKING MODE LIGHT DEVICE UNLIMITED CANCEL LINKED MODE UNLINKED MODE Programming SMART2 Remoteto Contro...

Page 13: ...e Outputs and press Select STEP 5 Arrow up or down to highlight back arrow symbol and press Select to delete unwanted characters STEP 6 Arrow up or down to desired characters and enter by pressing Select When done arrow to Accept and press Select STEP 7 Remote will confirm name has been changed Press Select button to finish delete unwanted characters with this symbol STEP 1 From Main Menu arrow to...

Page 14: ...smart2 liteall control module junction block smartwire adapter smartwire conductor socket 12v power out to 4500 series system plug POWER SUPPLIED FROM SMARTWIRE LITEALL WITH PROTRAP extension cable supplying power to front protrap smart2 liteall control module smartwire adapter junction block to rear protrap ...

Page 15: ... 16 ga or larger wire POWER SUPPLIED FROM JUNCTION BOX positive battery connection 12v negative battery connection black wire to negative post crimp 1 4 ring terminal to black wire white wire to positive post crimp 1 4 ring terminal to white wire 12v supply to 4500 receiver box if present gnd connection to 4500 receiver box if present ...

Page 16: ......

Reviews: