background image

 

 

Thanks for choosing SPARKULAR

®  

II , we wish it will sparks up your show.  

Please read the following manual carefully before operating this product. 

 

Δ

 

Safety Instructions 

\

 

Unauthorized repair are prohibited, it may cause serious incident. 

\

 

Keep SPARKULAR

®

 II dry. 

\

 

Make sure lid of feeding hopper are well covered when use SPARKULAR

®

 II  

\

 

Accidentally burning of consumable can only use sands to extinguish.  

\

 

Consumable should keep away from moisture and stored in a dry sealed environment. 

\

 

Check  whether  there  is  consumable  aggregate  in  the  output  nozzle  both  before  and  after 

each show, if any, please clean it up, or it will affect the firing effect, damage machine, even 

cause serious incident. 

\

 

There  will  be some sparks  drop  to  ground,  make  sure there  is  no  flammable  objects such  as 

carpet on the ground within the safety radius of the machine. 

\

 

Suggest to use HC8200 MEDIUM or SMALL for indoor events. 

\

 

The  SPARKULAR

®

  II  power  supply  cable  maximum  allowed  cascade  of  6pcs  (220V  version)  / 

3pcs (110V version), exceed connecting may result in damage or even cause fire. 

\

 

For better heat dissipation, block the air intake and air outlet is prohibited. 

\

 

Cover  the  output  nozzle  of  SPARKULAR

®

  II  is  forbidden,  inspect  the  machine  before  each 

show, making sure no objects or material will block the output nozzle. 

\

 

Never touch the nozzle of SPARKULAR

®

 II danger of getting burnt. 

\

 

Never touch the sparks which shooting out from the nozzle. 

 

Safety Distance

 

\

 

Keep  audience  and  flammable  material  at  a  minimum  distance  of  1m  (when  use  HC8200 

SMALL and MEDIUM) or 1.5m (when use HC8200 LARGE) from SPARKULAR®  II. 

\

 

Make  sure  sparks  shoot  out  from  SPARKULAR®   II  can  NOT  touch  any  objects.  And  keep  a 

clearance with minimum 1m from the setting maximum effect height.  

\

 

In windy environment, increase the safety distance according to the wind direction and speed.  

\

 

The safety zone area shifts accordingly when machine installed in tilt position. Please increase 

the safety distance in the direction which machine tilt.  

\

 

Sparks and consumables from the machine can lead to serious eye injury. Always wear safety 

goggles when enter the safety zone.  

 

 

 

 

 

 

 

 

 

Summary of Contents for SPARKULAR II

Page 1: ...USER MANUAL SPARKULAR II V1 0 2022 07 28 Showven Technologies Co Ltd ...

Page 2: ......

Page 3: ...ascade of 6pcs 220V version 3pcs 110V version exceed connecting may result in damage or even cause fire For better heat dissipation block the air intake and air outlet is prohibited Cover the output nozzle of SPARKULAR II is forbidden inspect the machine before each show making sure no objects or material will block the output nozzle Never touch the nozzle of SPARKULAR II danger of getting burnt N...

Page 4: ...ture and real time motor status monitoring ensure less stuck and safer firing 3 2 LCD color screen touch keypad flat structure design etc modern features makes it more user friendly when operating the system Δ Technical Specifications DIMENSION 286 280 258mm WEIGHT 9kg VOLTAGE AC200 240V AC100 120V 50 60Hz WORK POWER 500W EFFECT HEIGHT ADJUSTBLE YES INTERFACE 3 pin and 5 pin XLR POWER IN OUT CONTR...

Page 5: ...ructure of SPARKULAR II 1 Output Nozzle 2 Feeding Hopper Lid 3 LCD Screen 4 3 PIN DMX IN 5 3 PIN DMX OUT 6 5 PIN DMX IN 7 5 PIN DMX OUT 8 Fuse 9 Power Switch 10 Power IN 11 Power OUT Diagram of Bottom Panel ...

Page 6: ...onitoring of main part inside machine 2 RFID area RFID card come with consumable HC8200 bags swiping card to identify parameters and types of granules The RFID card is disposable one card can only use one time Each card can increase single machine 20min working time the maximum recharge time for SPARKULAR II is 30min ...

Page 7: ...rmation Error information Explanation E0 System IC Systematic error E1 Motor condition Blower motor shaft motor or feeding motor error E2 Temp Sensor Temperature sensor is not connected or damaged E3 P Temp Over Machine shutdown due to chassis over temperature E4 Time Remain Firing time is insufficient please swipe RFID card E5 K Temp Over Machine shutdown due to heating chamber over temperature E...

Page 8: ...s 1 512 1 Set DMX Address Set Safety Address 1 512 3 Safety address under 3CH P channel mode DMX Channel Mode 2 channel mode Jet Mode Normal Silent Normal Silent Mode with lower noisy while height will be lower Fountain Height 1 10 5 Manual firing height adjust for test purpose Manual Heat ON OFF OFF Auto heating up ON OFF Manual Fountain ON OFF OFF Auto preheat function switch after turn on machi...

Page 9: ...amount Motor Protect ON OFF OFF Motor protect function default setting is OFF Tip Over ON OFF ON Tilt function switch when machine slant over 45 degree it will stop working Standby Switch ON OFF ON When ON the machine can firing only when heating up was finished Default Parameter ON OFF OFF Parameters reset to default setting Mode Selection Factory Mode User Mode User Mode Factory mode is for engi...

Page 10: ...60 80 Clear Material 20 40 EMERGENCY STOP 0 10 Pre heat OFF disabled when auto heat ON 240 255 Pre heat ON disabled when auto heat ON First Channel Function 0 15 Fountain Off 16 39 Fountain Height 1 40 63 Fountain Height 2 64 87 Fountain Height 3 88 111 Fountain Height 4 112 135 Fountain Height 5 136 159 Fountain Height 6 160 183 Fountain Height 7 184 207 Fountain Height 8 208 231 Fountain Height ...

Page 11: ...he right side as below picture b Make sure the machine is securely installed to avoid tipping c The safety zone area shifts accordingly when machine installed in tilt position Please increase the safety distance in the direction which machine tilt d Check carefully the output nozzle of each machine make sure the output nozzle is in good shape and there is no powder aggregate 2 Fill SPARKULAR a Ope...

Page 12: ...emote controller For DMX cable control please execute below operations f to h f Connect a DMX cable to the DMX IN socket of first unit of SPARKULAR II connect the male connector end of DMX cable to your DMX controller FXcommander HOST CONTROLLER light console etc g Connect a DMX cable to the DMX OUT of previous machine and the other end of to the DMX IN of next machine Connect all devices in serie...

Page 13: ...n up a Power off SPARKULAR II allow SPARKULAR II to cool down b Disconnect all POWER and DMX cables c Empty the remaining HC8200 in hopper and store the remaining HC8200 in a dry sealed bottle for next time use Never touch the output nozzle of SPARKULAR II when empty the hopper DANGER OF GET BURNT d Operators can use handheld vacuum cleaner to empty the feeding hopper Do make sure the machine was ...

Page 14: ...nty period Please don t repair machine without factory permission Below situations NOT included in warranty service Damage caused by use other type of consumable which is not from SHOWVEN or SHOWVEN authorized distributor Damage caused by improper transportation usage management and maintenance or damage caused by human factors Disassemble modify or repair products without permission Damage caused...

Page 15: ......

Page 16: ...Showven Technologies Co Ltd Tel 86 731 83833068 Web www showven cn E mail info showven cn Add No 1 Tengda Road Liuyang Economic Technical Development Zone 410300 Changsha Hunan P R China ...

Reviews: