background image

 

  

  

10 

 

 

 

Ordercode: 30730/30731 

Stagebeam MKII 2000W Fresnel 

Set Up and Operation 

Follow the directions below, as they pertain to your preferred operation mode. 
Before plugging the unit in, always make sure that the power supply matches the product specification 

voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa. 

Connect the device to the main power supply. 
 

Power ON 

01)

 

Connect the device to an appropriate power supply. 

 

Maintenance 

The operator has to make sure that safety-related and machine-technical installations are to be 

inspected by an expert after every year in the course of an acceptance test. 

The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by a skilled person once a year. 

 

The following points have to be considered during the inspection: 
01)

 

All screws used for installing the device or parts of the device have to be tightly connected and 

must not be corroded. 

02)

 

There may not be any deformations on housings, fixations and installation spots. 

03)

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

04)

 

The electric power supply cables must not show any damages or material fatigue. 

 
The Stagebeam MKII 2000W Fresnel requires almost no maintenance. However, you should keep the unit 

clean. Otherwise, the fixture’s light output will be significantly reduced. Disconnect the mains power 

supply, and then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass 
cleaner and a soft cloth. Do not use alcohol or solvents. 

The front lens will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light 
output very quickly. 

Please clean internal components once a year with a light brush and vacuum cleaner.  

Make sure connections are thoroughly dry before supplying electric power. 
 

Changing the Lamp 

01)

 

Disconnect mains power supply. Remove the beam angle adjustment screw on the back of the 

device. 

02)

 

Allow 15 minutes to cool the lamp down. 

03)

 

Remove the top cover. 

04)

 

Follow directions for installing the lamp, page 8. 

 

 

 

 

Summary of Contents for STAGEBEAM MKII 2000W FRESNEL V1

Page 1: ...Stagebeam MKII 2000W Fresnel V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 30730 30731 MANUAL ENGLISH...

Page 2: ...tions 4 Rigging 4 Return Procedure 6 Claims 6 Description of the device 7 Overview 7 Installation 8 Installing the Lamp 8 Adjusting the Beam Angle 9 Filter Frame Retaining Clip 9 Set Up and Operation...

Page 3: ...Your shipment includes Stagebeam MKII 2000W Fresnel with a Schuko power cable 1 m Filter frame User manual Safety Instructions Every person involved with the installation operation and maintenance of...

Page 4: ...nnect power from the mains when device is not used or before cleaning or when replacing lamp Only handle the power cord holding it by the plug Never pull out the plug by tugging the power cord Make su...

Page 5: ...t circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safe...

Page 6: ...s Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE...

Page 7: ...phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform...

Page 8: ...t plastic Color Black 30730 Silver 30731 Connections Schuko power cable 1 m Dimensions 425 x 325 x 400 mm LxWxH Weight 6 8 kg Optional accessories 30719 Filterframe Stagebeam 2000 MKII 30736 Barndoor...

Page 9: ...fered in the future Check your product specification label for information Always disconnect from electric mains power supply before changing lamps The lamp has to be replaced when it is damaged or de...

Page 10: ...he left or right to increase decrease the beam angle Fig 03 Filter Frame Retaining Clip 01 Push the retaining clip sideways to open 02 Insert the filter frame 03 Release the retaining clip to close 04...

Page 11: ...t not be corroded 02 There may not be any deformations on housings fixations and installation spots 03 Mechanically moving parts like axles eyes and others may not show any traces of wearing 04 The el...

Page 12: ...ec dealer 04 If all appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Stagebeam as this may damage the unit and the warranty will beco...

Page 13: ...lor Black 30730 Silver 30731 Connections Schuko power cable 1 m Allowed lamp models 80805G GY16 GE 80805O GY16 Osram 80805P GY16 Philips 80805S GY16 Sylvania Max ambient temperature ta 25 C Max housin...

Page 14: ...13 Ordercode 30730 30731 Stagebeam MKII 2000W Fresnel Dimensions...

Page 15: ...14 Ordercode 30730 30731 Stagebeam MKII 2000W Fresnel...

Page 16: ...2017 Showtec...

Reviews: