background image

 

Ordercode: 50756 

 

Single WDP-1 

 

 

Notes 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

12 

   

 

Summary of Contents for Single WDP-1

Page 1: ...Single WDP 1 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50756 MANUAL ENGLISH ...

Page 2: ...n Example 6 Set Up and Operation 7 Linking 7 Wireless Status LED Indicator 7 Unlinking 7 Control Panel 8 Control Mode 8 DMX Addressing 8 Menu Overview 8 Main Menu Options 9 1 Remote Control Manual Control 9 2 DMX Addressing Fun1 9 3 Dimmer Switch Fun1 9 4 Dimmer Limit Fun1 9 5 WDP Control Fun1 9 6 Dimmer Preset Fun2 9 7 Full On Fun2 10 DMX Channels 10 1 channel 10 Maintenance 10 Replacing the Fuse...

Page 3: ...s Showtec Single WDP 1 with a power cable 1 m Remote dimming fader with a power cable 1 9 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should there be any consult your deal...

Page 4: ...ic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If your Showtec device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Showtec dealer for service Fo...

Page 5: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of mer...

Page 6: ...tic Color Grey Fuse F10L 250V Dimensions 100 x 95 x 273 mm LxWxH Weight 1 4 kg Optional accessories 50231 W DMX Micro F 1 Transceiver 50236 W DMX BlackBox F 1 MKII G4 Transceiver Overview Fig 01 01 Wireless DMX antenna 02 10A Schuko OUT Connect a light source 03 Manual dimming fader HTP Move the fader up and down to adjust the dimmer brightness 04 LED display control buttons 05 Fuse F10L 250V 06 2...

Page 7: ...value then the fader input will take precedence over the DMX input Installation Remove all packing materials from the Single WDP 1 Check if all foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not sub...

Page 8: ...e instructions from your transmitter s user manual It is not possible to link devices from the Single WDP 1 02 Make sure that the device is not linked to a transmitter 03 Check the Wireless status LED F see the control panel page 8 and compare with the chart below fig 03 Wireless Status LED Indicator Fig 03 Unlinking It is possible that before being able to use the Single WDP 1 you will need to un...

Page 9: ...he controller Please note when you use the controller the unit has 1 channel Controlling After having addressed all WDP fixtures you may now start operating these via your lighting controller Note After switching on the WDP will automatically detect whether DMX 512 data is received or not If there is no data received at the DMX input the LED on the control panel will not flash If not the problem m...

Page 10: ...03 The currently selected DMX address will be automatically saved 3 Dimmer Switch Fun1 01 Press the MENU button until the display shows 02 Press the UP DOWN buttons to choose between and 03 If set to then it is possible to remotely dim the light output 04 If set to then it is possible to switch the light output on off 4 Dimmer Limit Fun1 01 Press the MENU button until the display shows 02 Press th...

Page 11: ...tions with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Replacing the Fuse Power surges short circuit or inappropriate electrical power supply may cause a fuse to burn out If the fuse burns out the product will not function whatsoever If this happens follow the directions below 01 Unplug the unit from electric power source 02 Insert a s...

Page 12: ...UT Output 10A Schuko Electro mechanical effects Housing Metal flame retardant plastic Color Grey Control 50 mm dimming fader Voltage and amperage indication LED display Max ambient temperature ta 5 C 35 C Max housing temperature tB 80 C Minimum distance Minimum distance from flammable surfaces 0 5 m Design and product specifications are subject to change without prior notice Website www Showtec in...

Page 13: ...Ordercode 50756 Single WDP 1 Notes 12 ...

Page 14: ...Ordercode 50756 Single WDP 1 13 ...

Page 15: ...Ordercode 50756 Single WDP 1 14 ...

Page 16: ... 2016 Showtec ...

Reviews: