SHOWTEC phantom 75 LED Manual Download Page 24

 

22 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

 

Problem 

Probable cause(s) 

Remedy 

 
One or more 
fixtures are 
completely dead. 

No power to the fixture 

• Check that power is switched on 

and cables are plugged in. 

Primary fuse blown. 

• Replace fuse. 
 

Fixtures reset 
correctly, but all 
respond 
erratically or not 
at all to the 
controller. 

The controller is not connected. 

• Connect controller.  

3-pin XLR Out of the controller 
does not match XLR Out of the first 
fixture on the link (i.e. signal is 
reversed). 

• Install a phase reversing cable 

between the controller and the first 
fixture on the link. 

 
 
 
 
 
 
 
 
 
 
Fixtures reset 
correctly, but 
some respond 
erratically or not 
at all to the 
controller. 

 
 
 
Poor data quality 

• Check data quality. If much lower 

than 100 percent, the problem may 
be a bad data link connection, poor 
quality or broken cables, missing 
termination plug, or a defective 
fixture disturbing the link. 

 
Bad data link connection 

• Inspect connections and cables. 

Correct poor connections. Repair or 
replace damaged cables.  

Data link not terminated with 120 
Ohm termination plug. 

• Insert termination plug in output jack 

of the last fixture on the link. 

Incorrect addressing of the fixtures.  • Check address setting.  
 

 

One of the fixtures is defective and 
disturbs data transmission on the 
link. 

• Bypass one fixture at a time until 

normal operation is regained: unplug 
both connectors and connect them 
directly together. 

• Have the defective fixture serviced 

by a qualified technician.  

 
3-pin XLR Out on the fixtures does 
not match (pins 2 and 3 reversed). 

• Install a phase-reversing cable 

between the fixtures or swap pin 2 
and 3 in the fixture, that behaves 
erratically.  

Shutter closes 
suddenly 

The color wheel, gobowheel or a 
gobo has lost its index position and 
the fixture is resetting the effect. 

• Contact a technician for servicing 

the problem persists. 

 

 

 
No light or lamp 
cuts out 
intermittently 

Fixture is too hot. 

• Allow fixture to cool. 
• Clean fan. 
• Make sure air vents at control panel 

and front lens are not blocked. 

•  Turn up the air conditioning . 

 

LEDs damaged 

• Disconnect fixture and return to your 

dealer. 

The power supply settings do not 
match local AC voltage and 
frequency. 

• Disconnect fixture. Check settings 

and correct if necessary. 

 

Summary of Contents for phantom 75 LED

Page 1: ...Phantom 75 LED Beam ORDERCODE 40190 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Page 2: ...y on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep y...

Page 3: ...MX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 DMX Addressing 14 Built in Programs Mode 15 Pan movement Mode...

Page 4: ...tly reduced If improving your lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overal...

Page 5: ...ug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rea...

Page 6: ...afety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let th...

Page 7: ...ith the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN R...

Page 8: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 9: ...ainbow flow effect Rotating Gobowheel with 6 metal gobos and open with Gobo Shake Function No replaceable gobos Rotation Bi directional Prism 3 facet prism Gobo functions Gobo flow effect Gobo shake 8...

Page 10: ...ly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they...

Page 11: ...evice Turn on the music If the device is set to sound control then the Phantom will react to the beat of the music Please see page 15 for more information about the sound control options Multiple Phan...

Page 12: ...l cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 5 Supply electric power Plug electric mains power cords into e...

Page 13: ...Maximum recommended DMX data link distance 100 meters Maximum recommended number of Phantoms on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data cables You can p...

Page 14: ...3 the DMX address of the third Phantom should be 13 12 25 d025 etc Please be sure that you don t have any overlapping channels in order to control each Phantom correctly If two or more Phantoms are ad...

Page 15: ...13 Menu Overview...

Page 16: ...s Pan 540 360 180 Tilt 270 180 90 Reset Load factory default settings DMX Addressing With this menu you can set the DMX address 1 Press Mode Esc until the display shows 2 Press Enter to confirm You ca...

Page 17: ...lay will show The device is now a slave device It will now react the same as its master Pan movement Mode When the display shows the device is in normal Pan Mode When you press Up Down The display wil...

Page 18: ...s ENTER the device will return to the factory default settings Password Change This is a Service Function Press and hold MODE ESC for 2 seconds The display will show 0000 Press the Up button to change...

Page 19: ...so called Rainbow effect 0 6 Open White 7 13 Yellow 14 20 Pink 21 27 Green 28 34 Red 35 41 Light Blue 42 48 Light Green 49 55 Orange 56 63 Dark Blue 64 70 Split Color White Yellow 71 77 Split Color Y...

Page 20: ...ovement 56 95 No Function 96 103 Reset Pan 104 111 Reset Tilt 112 119 Reset Colorwheel 120 127 Reset Gobowheel 128 135 No Function 136 143 Reset Prism 144 151 No Function 152 159 Reset All channels 16...

Page 21: ...r Green Red 92 98 Split Color Red Light Blue 99 105 Split Color Light Blue Light Green 106 112 Split Color Light Green Orange 113 119 Split Color Orange Dark Blue 120 127 Split Color Dark Blue White 1...

Page 22: ...echanically moving parts like axles eyes and others may not show any traces of wearing 4 The electric power supply cables must not show any damages or material fatigue The Showtec Phantom 75 LED Beam...

Page 23: ...y out the steps below in sequence until a solution is found Once the unit operates properly do not carry out following steps If the light effect does not operate properly refer servicing to a technici...

Page 24: ...d with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and d...

Page 25: ...t colors Rainbow flow effect Rotating Gobowheel with 6 metal gobos and open with Gobo Shake Function No replaceable gobos Rotation Bi directional Prism 3 facet prism Gobo functions Gobo flow effect Go...

Page 26: ......

Reviews: