background image

 

  

 

 

14 

   

 

Ordercode: 33090 

Performer Profile Mini MKII 3200K 

Cleaning 

Please follow the next recommendations when cleaning and inspecting lenses and reflectors:  
Do not use glass or window type cleaners on lenses (glass or polymer) or reflectors.  
Do not use abrasive materials such as steel wool.  
Replace lenses if they contain visible damage (cracks or deep scratches) which that may impair their 
effectiveness.  
 

Cleaning 19°, 26°, and 36° Glass Lenses  

01)

 

Remove the beam focus controls at the bottom of the barrel. Remove the lens tube from the barrel.  

02)

 

Dampen a clean lint-free cloth with vinegar or household ammonia. You may also use water, but it 
will leave spots that can be removed by gently polishing the lens with a clean and dry cloth. 

03)

 

Starting from the center, gently wipe the lens. 

04)

 

Slide the lens tube back into the barrel with the color frame-retaining clip on top. Replace the beam 
focus controls. 

 

Cleaning the Reflector 

 

 

Unplug the fixture before attempting to clean the reflector. To quickly clean the reflector, 

remove the lens tube and clean the dust from the reflector with a blast of oil-free air.  

You may also wipe the reflector with a clean lint-free cloth. If either method is not 

sufficient, follow the instructions below. You will need a screwdriver to complete this 

procedure. 

 

 
01)

 

Remove the barrel rotation controls located at the bottom of the barrel. Use a screwdriver to remove 
the retainer bolt located on top of the reflector housing. 

02)

 

Rotate the barrel by 45° in either direction. Carefully remove the barrel from the reflector housing. 

03)

 

Dampen a clean lint-free cloth with alcohol or distilled water (alcohol is recommended). 

04)

 

Gently wipe the reflector. 

05)

 

Insert the barrel into the reflector housing with the gobo slot on top (line up the triangles on both 
parts). 

06)

 

While pressing in gently, rotate the barrel by 45° clockwise until it sets into position. Then, rotate the 
barrel counterclockwise by 45°. The barrel should be firmly attached and the triangles should line up 
again. 

07)

 

Replace the barrel rotation controls and tighten the retainer bolt. 

 

Maintenance 

The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test. 
The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by a skilled person once a year. 
 
The following points have to be considered during the inspection: 
01)

 

All screws used for installing the device or parts of the device have to be tightly connected and 
must not be corroded. 

02)

 

There may not be any deformations on housings, fixations and installation spots. 

03)

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

04)

 

The electric power supply cables must not show any damages or material fatigue. 

 
The Performer Profile Mini MKII 3200K requires almost no maintenance. However, you should keep the unit 
clean. 
Otherwise, the fixture’s light output will be significantly reduced. Disconnect the mains power supply, and 
then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and 
a soft cloth. Do not use alcohol or solvents. 
The front lens will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light-
output very quickly. 
Please clean internal components once a year with a light brush and vacuum cleaner.  
Make sure connections are thoroughly dry before linking equipment or supplying electric power. 
 

 

Summary of Contents for Performer Profile Mini MKII 3200K

Page 1: ...Performer Profile Mini MKII 3200K V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 33090 MANUAL ENGLISH...

Page 2: ...n 8 Lens Locations 9 Focusing the Beam 9 Gobo Slot 9 Color Frame Retaining Clip 10 Shaping the Beam 10 Rotating the Barrel 10 Control Modes 11 Manual Dimmer Control 11 Manual Dimmer Setup 11 Multiple...

Page 3: ...xhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If i...

Page 4: ...east 50 cm around the unit for ventilation Always disconnect power from the mains when device is not used or before cleaning Only handle the power cord holding it by the plug Never pull out the plug b...

Page 5: ...ead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging tru...

Page 6: ...o the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER N...

Page 7: ...phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform...

Page 8: ...Schuko power cable 3 pin DMX signal connector IN OUT Mounting Portable track mount Housing Die cast aluminum Cooling Forced convection Color Black IP rating IP20 Dimensions 150 x 106 x 225 mm LxWxH W...

Page 9: ...supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject t...

Page 10: ...ed tighten the beam focus controls Fig 04 Gobo Slot The gobo slot is located on the top of the barrel and is supposed to accommodate the gobo holder 33086 When the slot is not in use a small sheet met...

Page 11: ...by pushing it sideways until it opens 02 Insert the color frame s 03 Lock the retaining clip by pushing it to the initial position until it is secured Fig 06 Shaping the Beam You may shape the beam wi...

Page 12: ...des for air circulation 02 Always use a safety cable ordercode 70140 70141 03 Plug the end of the electric mains power cord into a proper electric power supply socket 04 Turn the manual dimmer control...

Page 13: ...er devices 04 Link the units as shown in fig 09 Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourt...

Page 14: ...wn cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio...

Page 15: ...ipe the reflector 05 Insert the barrel into the reflector housing with the gobo slot on top line up the triangles on both parts 06 While pressing in gently rotate the barrel by 45 clockwise until it s...

Page 16: ...MX cable or connectors a controller malfunction a light effect DMX card malfunction 01 Check the DMX setting Make sure that DMX addresses are correct 02 Check the DMX cable Unplug the unit change the...

Page 17: ...anual DMX RDM Lux 1 m 15000 19 Color rendering 90Ra Color temperature 3200K Housing Die cast aluminum Connections Schuko power cable 3 pin DMX signal connector IN OUT Mounting Portable track mount Col...

Page 18: ...17 Ordercode 33090 Performer Profile Mini MKII 3200K Notes...

Page 19: ...18 Ordercode 33090 Performer Profile Mini MKII 3200K...

Page 20: ...2019 Showtec...

Reviews: