background image

 

Ordercode: 43151 

Hydrogen DMX MKII 

Before the initial start-up, please make sure that there is no damage caused by transportation. Should 

there be any, consult your dealer and do not use the device. 

 

To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 

follow the safety instructions and warning notes written in this manual. 

 

Please consider that damages caused by manual modifications to the device are not subject to 

warranty. 

 

This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 

 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 

this manual or any unauthorized modification to the device. 

 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 

connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Do not open the device and do not modify the device. 

 

Never use anything to cover the ground contact. 

 

Never leave the device running without a lamp! 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this would reduce the device’s life. 

 

Do not shake the device. Avoid brute force when installing or operating the device. The Hydrogen 

DMX MKII reacts very sensitively to movement. 

 

Never use the device during thunderstorms, unplug the device immediately. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes hot). 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 

the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Only install the device with the hanging bracket. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power-

cord from time to time. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If the lens or glass is obviously damaged, it has to be replaced. So that its functions are not impaired, 

due to cracks or deep scratches. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 

engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 

switch it on immediately. The arising condensation water might damage your device. Leave the 

device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 

(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Light effect must be installed out of the reach of children. Never leave the unit 

running unattended. 

 

For replacement, use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the Hydrogen DMX MKII. The 

manufacturer will not accept liability for damages caused by the misuse or incorrect installation of 

this device. 

 

 

  

 

 

   

 

Summary of Contents for Hydrogen DMX MKII

Page 1: ...Hydrogen DMX MKII V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 43151 MANUAL ENGLISH...

Page 2: ...9 Control Modes 9 One Hydrogen Built in Programs 9 Multiple Hydrogens Master Slave Mode 9 Multiple Hydrogens DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Add...

Page 3: ...n DMX MKII including a hanging bracket IEC power cable 1 5 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration...

Page 4: ...operate the device after having familiarized with its functions Avoid flames and do not put close to flammable liquids or gases Always keep case closed while operating Always allow free air space of a...

Page 5: ...er way than the one described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You...

Page 6: ...the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL...

Page 7: ...umber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this ch...

Page 8: ...ndard DMX controller 4 DMX channels Fixture Connection XLR Data in out XLR 3 pin 4 digit LED display Housing Black Metal Flame retardant plastic Long LED lifetime Strobe 20Hz Power connector IEC In Ou...

Page 9: ...DMX is required to fully utilize this unit Installation Remove all packing materials from the Hydrogen DMX MKII Check if all foam and plastic padding is removed Connect all cables Do not supply power...

Page 10: ...it functions as a stand alone device 05 Please see page 14 15 for more information about the built in programs Multiple Hydrogens Master Slave Mode 01 Fasten the effect light onto firm trussing Leave...

Page 11: ...ces 05 Link the units as shown in Fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 06...

Page 12: ...digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of Hydrogens on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain d...

Page 13: ...ase make sure that you do not have any overlapping channels in order to control each Hydrogen correctly If two or more Hydrogens are addressed similarly they will work similarly Controlling After havi...

Page 14: ...Ordercode 43151 Hydrogen DMX MKII Menu Overview 13...

Page 15: ...button and observe the display If appears on the display the reset process was not completed successfully If appears on the display the reset process was successful 04 While in this menu press the SET...

Page 16: ...u you can set the Master or Slave 01 Press the MODE button and then the Up and Down buttons until the display shows If the device has not been set to slave it is automatically classified as a master d...

Page 17: ...power source 02 Insert a screwdriver into the slot in the fuse cover Gently pry up the fuse cover The fuse will come out 03 Remove the used fuse If brown or unclear it is burned out 04 Insert the repl...

Page 18: ...ted with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and...

Page 19: ...White Mounting Mounting bracket DMX control Via standard DMX controller On Board Display for easy set up Control DMX 512 Built in Programs Auto Manual color Master Slave Light Source 1 x 20W LED Beam...

Page 20: ...Ordercode 43151 Hydrogen DMX MKII Dimensions 19...

Page 21: ...Ordercode 43151 Hydrogen DMX MKII Notes 20...

Page 22: ...Ordercode 43151 Hydrogen DMX MKII 21...

Page 23: ...Ordercode 43151 Hydrogen DMX MKII 22...

Page 24: ...2014 Showtec...