39
Ordercode: 43725
Helix S5000 Q4
Channel 9 – Red (section 2)
CH1 must be open; CH3-4 must be closed
0-255
Gradual adjustment Red, from dark to brightest
Channel 10 – Green (section 2)
CH1 must be open; CH3-4 must be closed
0-255
Gradual adjustment Green, from dark to brightest
Channel 11 – Blue (section 2)
CH1 must be open; CH3-4 must be closed
0-255
Gradual adjustment Blue, from dark to brightest
Channel 12 – White (section 2)
CH1 must be open; CH3-4 must be closed
0-255
Gradual adjustment White, from dark to brightest
Channel 21 – Red (section 5)
CH1 must be open; CH3-4 must be closed
0-255
Gradual adjustment Red, from dark to brightest
Channel 22 – Green (section 5)
CH1 must be open; CH3-4 must be closed
0-255
Gradual adjustment Green, from dark to brightest
Channel 23 – Blue (section 5)
CH1 must be open; CH3-4 must be closed
0-255
Gradual adjustment Blue, from dark to brightest
Channel 24 – White (section 5)
CH1 must be open; CH3-4 must be closed
0-255
Gradual adjustment White, from dark to brightest
Maintenance
The Showtec Helix S5000 Q4 requires almost no maintenance. However, you should keep the unit clean.
Otherwise, the fixture’s light output will be significantly reduced. Disconnect the mains power supply and
then wipe the cover with a damp cloth. Wipe the front glass panel clean with glass cleaner and a soft
cloth. Do not use alcohol or solvents. The front glass panel will require weekly cleaning, as smoke-fluid
tends to build up residues, reducing the light output very quickly. Do not immerse in liquid.
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying
electric power.
The operator has to make sure that safety-related and machine-technical installations are to be
inspected by an expert after every year in the course of an acceptance test.
The operator has to make sure that safety-related and machine-technical installations are to be
inspected by a skilled person once a year.
The following points have to be considered during the inspection:
01)
All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
02)
There may not be any deformations on housings, fixations and installation spots.
03)
Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
04)
The electric power supply cables must not show any damages or material fatigue.