background image

 

Installation 

 

Installing the Lamp 

The Showtec Genesis Scan uses the CDM 150 (ordercode 80964, 80965, 80974, 80975) bulb as 
manufactured by all popular manufacturers. Use only the appropriate lamp for your unit. 
Note that, product versions that use other lamps, may be offered in the future. Check your product 
specification label for information. 

Always disconnect from electric mains power supply before changing lamps. 

The lamp has to be replaced when it is damaged or deformed due to the heat. 

Do not install lamps with a higher wattage

! Lamps with a higher wattage generate temperatures the 

device was not designed for.  

Damages caused by non-observance are not subject to warranty.

 

 

Procedure : 

1.

 Loosen the 4 screws on the back of the housing.  

2.

 Gently remove the metal housing. 

3.

 Read lamp instructions. Do not touch the lamp bulb glass. (See Figure 3.) 

    Oil on hands shortens the lamp life. (If you touch the bulb glass, wipe off the glass with a clean, lint-free  
    towel and rubbing alcohol.).  

4.

 Insert the lamp pins into the lamp socket. You can adjust the distance between the lamp and the lens  

   (screws A, B, C) on the back. 

5.

 Put the metal housing back and fasten the screws snugly. 

 

           1 

 

 

 

            

 

 

Fig. 3

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

Backside Lamp Board 

 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

Fig. 4 

 

 
 

Summary of Contents for Genesis Scan CDM-150

Page 1: ...Genesis Scan CDM 150 ORDERCODE 40020...

Page 2: ...n Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...tures and Overview Backside Installation Installing the Lamp Lamp Adjustment Set Up and Operation One Genesis Scan Multiple Genesis Scan DMX Protocol Control Panel Control Mode DMX addressing Stand al...

Page 4: ...nual modifications to the device are not subject to warranty This device contains no user serviceable parts Refer servicing to qualified technicians only IMPORTANT The manufacturer will not accept lia...

Page 5: ...ure fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If...

Page 6: ...installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the projector always make sure that the area below the in...

Page 7: ...coloured glass DMX control via standard DMX controller 7 DMX control channels required Sound controlled via built in microphone Lamp CDM 150 ordercode 80964 80965 80974 80975 Fuse T5A 250V No lamp inc...

Page 8: ...nstall lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Procedure 1 Loosen the...

Page 9: ...light on an even surface wall As the optimal distance between the lamp and the lens was already set during the installation with screw C only the Hot Spot the brightest part of the ray of light must...

Page 10: ...effect light onto firm trussing Use a 30 kg rated or stronger C clamp fastened onto the Genesis Scan Leave at least 1 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the Genes...

Page 11: ...95 Strobe effect with increasing speed 96 159 Open 160 191 Shutter slow open from left to right with increasing speed 192 223 Shutter slow open from right to left with increasing speed 224 255 Open C...

Page 12: ...84 Cyan 85 95 Orange 96 105 Magenta 106 116 Blue White Red 117 128 Cyan Magenta Pink Yellow 129 189 Change the colorwheel position step by step clockwise 190 222 Change the colorwheel position step b...

Page 13: ...s Scan should be 1 7 8 A008 the DMX address of the third Genesis Scan should be 8 7 15 A015 etc Please be sure that you don t have any overlapping channels in order to control each Genesis Scan correc...

Page 14: ...f the master fixture and into the output of the last slave fixture in the data link in order to ensure proper transmission on the data link Functions control panel The control panel is situated on the...

Page 15: ...No function No function Reset function This option enables the Genesis Scan to index all effects function and return to their standard positions Press until the display shows or If the display shows w...

Page 16: ...y shows with actually stored address If you want address no playing program don t select No function No function Display reverse With this function you can adjust the display by 180 Press until the di...

Page 17: ...moke fluid tends to build up residues reducing the light output very quickly The cooling fans dichroic colour filters the gobo wheel the gobos and the internal lenses should be cleaned monthly with a...

Page 18: ...lamp Replace the old lamp with a new one with the same specifications See page 6 for replacing lamps 3 The fuse Replace the fuse See page 15 for replacing the fuse No Response to DMX Response Suspect...

Page 19: ...jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a tim...

Page 20: ...fects Color wheel with variable rotation speed Rotating Gobo wheel 8 gobos 2 glass gobo and 6 metal gobo Colorwheel 8 Single colours 2 Bi colours open DMX control via standard DMX controller Sound con...

Page 21: ......

Reviews: