![SHOWTEC Genesis Barrel EHJ-250 Product Manual Download Page 14](http://html1.mh-extra.com/html/showtec/genesis-barrel-ehj-250/genesis-barrel-ehj-250_product-manual_1260697014.webp)
12
Stand-alone Mode
The fixtures on a data-link are not connected to the controller, but can execute pre-set programs, which
can be different for every fixture.
To set the program to be played, stand-alone operation can be applied to a single fixture (the fixture
may be set to the master/slave mode or controller mode) or to multiple fixture operating synchronously.
For synchronous operation of multiple fixtures the fixtures must all be connected on a data-link and one
of them is the master and the rest slaves. The DMX address of all the slaves are assigned to
and on
that particular slave address only one fixture can be connected. To the fixture as the master or slave,
see “Addressing” (menu
).
If the master fixture resets or runs a test (program), all slaves will execute these acts too.
You can’t play or edit any program on a slave, if the master is switched on and connected to the
master/slave chain.
It’s necessary to insert the XLR termination plug (with 120 Ohm ) into the input of the master fixture and
into the output of the last slave fixture in the data-link, in order to ensure proper transmission on the data
link.
Functions control panel
The control panel is situated on the front of the base and offers several features. You can simply set the
DMX address, make a reset and also use many functions for setting purposes.
The main menu of the control panel is accessed by pressing the Mode-button - press this one until the
display shows
(with actually stored address).
Browse the menu by pressing or buttons - the display will show :
Press if you wish to select one of them. The functions are described in the following sections and the
function hierarchy is shown below.
Functions outline
Version 101
- Display the version of the fixture
Reset
- Make an internal check
Function 1
- No function
Function 2
- No function
Function 3
– Reset
Function 4
- Run programs via the built-in microphone
Function 5
- Run a built-in program
Function 6
- No function
Function 7
- No function
Function 8
- Invert display direction
Pass
- Confirm information
Address 001
- Display the DMX address of the fixture (from
A001
to
A511
)
No
- Don’t select the present function
Yes
- Select the present function
Summary of Contents for Genesis Barrel EHJ-250
Page 1: ...Genesis Barrel EHJ 250 ORDERCODE 40011...