SHOWTEC Galaxy 1200 User Manual Download Page 5

3

  Only operate the fixture after having checked that the housing is firmly closed and all screws are

tightly fastened.

  Only operate the device after having familiarized with its functions.

  Avoid flames and do not put close to flammable liquids or gases.

  Always replace the lamp, when it is damaged or deformed due to the heat.

  Always keep case closed while operating.

  Always allow free air space of at least 50 cm around the unit for ventilation.

  Always disconnect power from the mains, when device is not used, before cleaning or when

replacing lamp! Only handle the power-cord by the plug. Never pull out the plug by tugging the
power-cord.

  Make sure that the device is not exposed to extreme heat, moisture or dust.

  Make sure that the available voltage is not higher than stated on the rear panel.

  Make sure that the power-cord is never crimped or damaged. Check the device and the power-cord

from time to time.

  If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due to

cracks or deep scratches.

  If device is dropped or struck, disconnect mains power supply immediately. Have a qualified

engineer inspect for safety before operating.

  If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not

switch it on immediately. The arising condensation water might damage your device. Leave the
device switched off until it has reached room temperature.

  If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely

(preferably in the original packing material), and return it to your Showtec dealer for service.

  For adult use only. Movinghead must be installed out of the reach of children. Never leave the unit

running unattended.

  For replacement use lamps and fuses of same type and rating only.

  Allow time to cool down, before replacing lamp.

  This device falls under protection class I. Therefore it is essential to connect the yellow/green

conductor to earth.

  During the initial start-up some smoke or smell may arise. This is a normal process and does not

necessarily mean that the device is defective.

 

Repairs, servicing and electric connection must be carried out by a qualified technician.

 

WARRANTY: Till one year after date of purchase.

OPERATING DETERMINATIONS

This device is not designed for permanent operation. Consistent operation breaks will ensure that the device
will serve you for a long time without defects.

The minimum distance between light-output and the illuminated surface must be more than 1.3 meter.

The maximum ambient temperature 

t

a

 must never be exceeded.

If this device is operated in any other way, than the one described in this manual, the product may suffer
damages and the

 

warranty becomes void.

Any other operation may lead to dangers like short-circuit, burns, electric shock, lamp explosion, crash etc.
You endanger your own safety and the safety of others!

CAUTION ! EYEDAMAGES !.

Avoid looking directly into the light source.

(meant especially for epileptics) !

Summary of Contents for Galaxy 1200

Page 1: ...Galaxy 1200 ORDERCODE 40405...

Page 2: ...Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you o...

Page 3: ...talling the Lamp Set Up and Operation One Galaxy Multiple Galaxys DMX Protocol Program Mode 13F 13 Channels Program Mode 19F 19 Channels Control Panel Control Mode DMX addressing Stand alone mode Func...

Page 4: ...ins with particular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never run the device without lamp Never ignite the lamp if the objec...

Page 5: ...t has reached room temperature If your Showtec device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Showte...

Page 6: ...swinging freely in the room The installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the projector always make...

Page 7: ...6 metal interchangeable rotating gobos plus open DMX control via standard DMX controller 13 19 DMX control channels required Strobe effect with adjustable speed 1 10 flashes sec Sound controlled via b...

Page 8: ...when it is damaged or deformed due to the heat Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non obser...

Page 9: ...o the beat of the music Multiple Galaxy s 1 Fasten the effect light onto firm trussing Use a 30 kg rated or stronger C clamp fastened onto the Galaxy Leave at least 1 meter on all sides for air circul...

Page 10: ...8 Fig 5...

Page 11: ...5 Tilt Push the slider up in order to move the mirror vertically TILT Gradual mirror adjustment from one end of the slider to the other 0 255 128 center The mirror can be turned by 90 and stopped at a...

Page 12: ...Positive rainbow effect with increasing speed 192 255 Negative rainbow effect with increasing speed Channel 10 Rotating Gobo wheel Mirror 2 5 0 15 16 31 Orange 32 47 Cherry 48 63 Green 64 79 80 95 Gl...

Page 13: ...255 Negative Gobo rotation with increasing speed Channel 13 Switching the Lamp Rest Internal Programs 0 DMX PAN TILT movement channel 1 12 or 1 6 is active 1 7 Movable macro 1 8 15 Movable macro 2 16...

Page 14: ...can be turned by 90 and stopped at any position you wish Channel 5 Horizontal movement Mirror 3 Pan Push the slider up in order to move the mirror horizontally PAN Gradual mirror adjustment from one e...

Page 15: ...mirror can be turned by 180 and stopped at any position you wish Channel 12 Vertical movement Mirror 6 Tilt Push the slider up in order to move the mirror vertically TILT Gradual mirror adjustment fr...

Page 16: ...1 Positive rainbow effect with increasing speed 192 255 Negative rainbow effect with increasing speed Channel 16 Rotating Gobo wheel Mirror 2 5 0 15 16 31 Orange 32 47 Cherry 48 63 Green 64 79 80 95 G...

Page 17: ...255 Negative Gobo rotation with increasing speed Channel 19 Switching the Lamp Rest Internal Programs 0 DMX PAN TILT movement channel 1 12 or 1 6 is active 1 7 Movable macro 1 8 15 Movable macro 2 16...

Page 18: ...DMX addresses right Therefore the DMX address of the first Galaxy should be 1 001 the DMX address of the second Galaxy should be 1 19 20 020 the DMX address of the third Galaxy should be 20 19 39 039...

Page 19: ...e 2 Slave Mode Slave Mode Slave 3 Slave Mode Slave 4 Program Mode 13 Channels Program Mode 19 Channels Fig 7 Remotely controllable functions Rotating gobo wheel This rotating gobo wheel has 6 metal go...

Page 20: ...particular slave address only one fixture can be connected To the fixture as the master or slave see Addressing menu If the master fixture resets or runs a test program all slaves will execute these a...

Page 21: ...a damp cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front PC lenses will require weekly cleaning as smoke fluid tends to build...

Page 22: ...bo Gobo Pan Fig 9 Fig 10 Troubleshooting No Light No Movement All Products This troubleshooting guide is meant to help solve simple problems If a problem occurs carry out the steps below in sequence u...

Page 23: ...ing One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operation is regained unplug both connectors and connect them directly togethe...

Page 24: ...ass and 6 rotating metal gobos and open Gobo rotation adjustable speed position direction All lenses are anti reflection coated High luminous efficiency parabolic system Strobe effect with variable sp...

Page 25: ...2005 Showtec...

Reviews: