background image

USER MANUAL

 

 

16

10. MAINTENANCE 

z

 

Make sure the area below the installation place is free from unwanted persons 

during servicing 

z

 

Switch off the unit , unplug the mains cable and wait until the unit has been 

cooled down. 

During the inspection the following points should be checked: 

z

 

All screws used for installing the device and any of its parts should be tightly 

fastened and may not be corroded 

z

 

Housings, fixations and installations spots( ceiling, truss, suspensions) should 

be totally free from any deformation 

z

 

When an optical lens is visibly damaged due to cracks or deep scratches, it 

must be replaced   

z

 

The mains cables must be in impeccable condition and should be replaced 

immediately when even a small problem is detected 

z

 

In order to protect the device from overheat the cooling fans(if any ) and 

ventilation openings should be cleaned monthly. 

z

 

The interior of the device should be cleaned annually using a vacuum cleaner 

or air-jet. 

z

 

The cleaning of internal and external optical lenses and / or mirrors must be 

carried out periodically to optimize light output. Cleaning frequency depends on 

the environment in which the fixture operates: damp. smoky or particularly dirty 

surroundings can cause    greater accumulation of dirt on the unit’s optics   

{

 

Clean with a soft cloth using normal glass cleaning products. 

{

 

  Always dry the parts carefully. 

{

 

Clean the external optics at least once every 30 days. 

{

 

Clean the internal optics at least very 90 days. 

Attention: We strongly recommend internal cleaning to be carried out by 

qualified personnel! 

 

 

 

 

 

 

 

 

 

Summary of Contents for Galactic G-30

Page 1: ...t laser system safety and operation information Read and understand all instructions prior to powering on laser unit the first time to avoid laser eye injury and to avoid breaking the law Keep this ma...

Page 2: ...rol z DMX addressing with LED display z Laser Safety key switch z Complies to EN IEC 60825 1 for Laser Safety 2 BEFORE USE z Before you start using this unit please check if there s no transportation...

Page 3: ...way from any flammable materials and or liquids The fixture must be fixed at least 50cm from surrounding walls z Don t cover any ventilation openings as this may result in overheating z Prevent use in...

Page 4: ...problems stop using the fixture and contact your dealer immediately z The housing and the lenses must be replaced if they are visibly damaged z Please use the original packing when the device is to b...

Page 5: ...llations and unskilled operation 5 OVERHEAD RIGGING z Important The installation must be carried out by qualified service personal only Improper installation can result in serious injuries and or dama...

Page 6: ...g and machine technical installations are approved by an expert before using them for the first time The installations should be inspected every year by a skilled person to be sure that safety is stil...

Page 7: ...DMX controllers you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you ne...

Page 8: ...ransmission on the data link 6 DESCRIPTION 6 1 Back panel of the fixture 1 POWER Switch Switch on and off the power 2 MAINS INPUT with IEC socket and integrated fuse holder connect the supplied mains...

Page 9: ...the space color laser with the next unit in the DMX chain 12 DMX INPUT 3pin male XLR connector used to connect universal DMX cables This input receives instructions from a DMX controller 6 2 Front pan...

Page 10: ...re and contact your dealer immediately z Important Never look directly into the laser beam Don t use the effect in the presence of persons suffering from epilepsy You can operate the unit in 5 Modes 7...

Page 11: ...am The laser is operating this mode until next setting 7 3 SLAVE MODE z Press FUNC button till to the SLA letter is shown on LED DISPLAY z Press ENTER to select this SLA mode When SLA mode is selected...

Page 12: ...ler as function list below The laser is operating this mode until next setting z STAND BY button Used to set the connected unit in blackout mode The LED is on when the unit is set to blackout z MODE F...

Page 13: ...CONTROL MODE and confirm the DMX address CAUTION In case of DMX cable disconnecting or no DMX signal is detected the DMX address on LED DISPLAY keeps flashing Please check the DMX cable connection Imp...

Page 14: ...127 Pattern Group 2 TUNNEL 128 191 Pattern Group 3 CURVE 192 255 Pattern Group 4 OTHERS 3 000 255 8 Patterns in each group in Channel 2 4 000 134 Rotation Position 135 255 Rotating Speed 5 0 128 Size...

Page 15: ...USER MANUAL 14 8 2 PATTERN LIST IN CHANNEL 3 DMX Group 1 Group 2 Group 3 Group 4 000 031 032 063 064 095 096 127 128 159 160 191 192 223 224 255...

Page 16: ...USER MANUAL 15 9 OUTPUT LASER ADJUSTMENT 9 1 To adjust the output laser beam position and direction 9 2 X Y AXIS ZOOMING ADJUSTMENT...

Page 17: ...replaced immediately when even a small problem is detected z In order to protect the device from overheat the cooling fans if any and ventilation openings should be cleaned monthly z The interior of...

Page 18: ...USER MANUAL 17 11 CIRCUIT DIAGRAM 3 2 1 3 2 1 B 5 0 K E N L...

Page 19: ...ser Diode Blanking 1 1000Hz z Sound Control Internal microphone z DMX connections 3pin XLR male female z DMX channels 8 channels z Laser Power 30mW Green CW laser 532nm z Laser radiation class 3B z La...