SHOWTEC Explorer 250 Wash User Manual Download Page 5

3

  Only operate the fixture after having checked that the housing is firmly closed and all screws are

tightly fastened.

  Only operate the device after having familiarized with its functions.

  Avoid flames and do not put close to flammable liquids or gases.

  Always replace the lamp, when it is damaged or deformed due to the heat.

  Always keep case closed while operating.

  Always allow free air space of at least 50 cm around the unit for ventilation.

  Always disconnect power from the mains, when device is not used, before cleaning or when

replacing lamp! Only handle the power-cord by the plug. Never pull out the plug by tugging the
power-cord.

  To ensure the longest and most efficient use of the lamp always wait 15 minutes before re-applying

power after a shutdown. Failure to do so could result in premature aging of the lamp and failure to
the electronics that drive it.

  Make sure that the device is not exposed to extreme heat, moisture or dust.

  Make sure that the available voltage is not higher than stated on the rear panel.

  Make sure that the power-cord is never crimped or damaged. Check the device and the power-cord

from time to time.

  If the lens is obviously damaged, it has to be replaced. So that its functions are not impaired, due to

cracks or deep scratches.

  If device is dropped or struck, disconnect mains power supply immediately. Have a qualified

engineer inspect for safety before operating.

  If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not

switch it on immediately. The arising condensation water might damage your device. Leave the
device switched off until it has reached room temperature.

  If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely

(preferably in the original packing material), and return it to your Showtec dealer for service.

  For adult use only. Movinghead must be installed out of the reach of children. Never leave the unit

running unattended.

  Never attempt to bypass the thermostatic switch or fuses.

  For replacement use lamps and fuses of same type and rating only.

  Replace the lamp if it becomes defective or worn out, or before usage exceeds the maximum service

life.

  Allow the fixture to cool down for 15 minutes, before opening the fixture and replacing lamp. Protect

your hands and eyes with gloves and safety glasses.

  This device falls under protection class I. Therefore it is essential to connect the yellow/green

conductor to earth.

  During the initial start-up some smoke or smell may arise. This is a normal process and does not

necessarily mean that the device is defective.

 

Repairs, servicing and electric connection must be carried out by a qualified technician.

 

WARRANTY: Till one year after date of purchase.

OPERATING DETERMINATIONS

This device is not designed for permanent operation. Consistent operation breaks will ensure that the device
will serve you for a long time without defects.

The minimum distance between light-output and the illuminated surface must be more than 1 meter.

The maximum ambient temperature 

t

a

 must never be exceeded.

CAUTION ! EYEDAMAGES !.

Avoid looking directly into the light source.

(meant especially for epileptics) !

Summary of Contents for Explorer 250 Wash

Page 1: ...Explorer 250 Wash ORDERCODE 40178...

Page 2: ...n Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...nd Overview Backside Installation Installing the Lamp Lamp Adjustment Beam Angle Set Up and Operation One Explorer Multiple Explorers Master Slave mode DMX Protocol Control Panel Control Mode DMX addr...

Page 4: ...informative labels from the unit Never use anything to cover the ground contact Never run the device without lamp Never ignite the lamp if the objective lens or any housing cover is open as discharge...

Page 5: ...ortation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If your Showtec device fails to wor...

Page 6: ...ceiling or high joists professional trussing systems have to be used Use a clamp to mount the projector with the mounting bracket to the trussing system The projector must never be fixed swinging free...

Page 7: ...with the power plug Always pay attention that the right color cable is connected to the right place Wire Color Pin International Brown Fase Live L Blue Nul Neutral N Yellow Green Earth Ground Make sur...

Page 8: ...lter and Beam shape DMX control via standard DMX controller 16 DMX control channels required Mechanical Dimmer Shutter Strobe Strobe effect with adjustable speed 1 10 flashes sec Linear electric focus...

Page 9: ...7 Backside 3 4 5 6 Fig 2 3 DMX signal connector OUT 4 DMX signal connector IN 5 IEC power connector 6 Fuse...

Page 10: ...due to the heat Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warrant...

Page 11: ...ray of light must be centered Turn in addition screw B and C If the Hot Spot appears too bright you can weaken its intensity by moving the lamp closer to the reflector Turn in addition screw A until t...

Page 12: ...10 Beam Angle...

Page 13: ...lect UP If the display shows PRG then select Enter Multiple Explorers 1 Fasten the moving head onto firm trussing Use a clamp ordercode 70351 70308 70322 fastened onto the Explorer Leave at least 1 me...

Page 14: ...The head can be turned by 530 and stopped at any position you wish Channel 2 Vertical movement Tilt Push the slider up in order to move head vertically TILT Gradual head adjustment from one end of the...

Page 15: ...o slow 255 Channel 12 CMY Color effect wheel 0 7 Open White 8 15 Color 1 16 23 Color 2 24 31 Color 3 32 39 Color 4 40 47 Color 5 48 55 Color 6 56 63 Color 7 64 71 Color 8 72 79 Color 9 80 87 Color 10...

Page 16: ...hutter open 64 95 Strobe effect from slow to fast 0 10 flashes sec 96 127 Shutter open 128 159 Pulse effect 1 in sequences from slow to fast 160 191 Shutter open 192 223 Random strobe effect from slow...

Page 17: ...xplorer should be 1 16 17 A017 the DMX address of the third Explorer should be 17 16 33 A033 etc Please be sure that you don t have any overlapping channels in order to control each Explorer correctly...

Page 18: ...eel can be positioned between two adjacent colours in any position It is also possible to rotate the colour wheel continuously at different speeds Shutter Dimmer Strobe The dimming 0 100 is provided b...

Page 19: ...e fixture the fixture may be set to the master slave mode or controller mode or to multiple fixture operating synchronously For synchronous operation of multiple fixtures the fixtures must all be conn...

Page 20: ...ables must not show any damages or material fatigue The Showtec Explorer requires almost no maintenance However you should keep the unit clean Otherwise the fixture s light output will be significantl...

Page 21: ...de is meant to help solve simple problems If a problem occurs carry out the steps below in sequence until a solution is found Once the unit operates properly do not carry out following steps If the li...

Page 22: ...ss setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operation is regained unplug both connectors and connect them directly...

Page 23: ...er 5600 K and 3200 K UV Effect wheel with Frost filter and Beam shape Safety protection Every safety standard IP20 protection grade All lenses are anti reflection coated High luminous efficiency parab...

Page 24: ...2006 Showtec...

Reviews: