background image

 

  

 

 

23 

   

 

Ordercode: 44010 

EventLITE 177IR 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

Problem 

Probable cause(s) 

Solution 

 
One or more 
fixtures do not 
function at all 

No power to the fixture 

• 

Check if power is switched on and 
cables are plugged in 

Primary fuse blown 

• 

Replace fuse 

Fixtures reset 
correctly, but all 
respond 
erratically or not 
at all to the 
controller 

The controller is not connected. 

• 

Connect controller.  

3-pin XLR Out of the controller 
does not match XLR Out of the first 
fixture on the link (i.e. signal is 
reversed) 

• 

Install a phase reversing cable 
between the controller and the 
first fixture on the link 

 
 
 
 
 
 
 
 
 
 
Fixtures reset 
correctly, but 
some respond 
erratically or not 
at all to the 
controller 

 
 
 
Poor data quality 

• 

Check data quality. If much lower 
than 100 percent, the problem 
may be a bad data link 
connection, poor quality or 
broken cables, missing termination 
plug, or a defective fixture 
disturbing the link 

 
Bad data link connection 

• 

Inspect connections and cables. 
Correct poor connections. Repair 
or replace damaged cables 

Data link not terminated with 120 
Ohm termination plug 

• 

Insert termination plug in output 
jack of the last fixture on the link 

Incorrect addressing of the fixtures  • 

Check address setting 

 
 
One of the fixtures is defective and 
disturbs data transmission on the 
link 

• 

Bypass one fixture at a time until 
normal operation is restored: 
unplug both connectors and 
connect them directly together. 

• 

Have the defective fixture 
serviced by a qualified technician  

 
3-pin XLR Out on the fixtures does 
not match (pins 2 and 3 reversed) 

• 

Install a phase-reversing cable 
between the fixtures or swap pin 2 
and 3 in the fixture that behaves 
erratically  

 
 
 
No light or LEDs 
cuts out 
intermittently 

Fixture is too hot 

• 

Allow the fixture to cool down 

• 

Clean the fan 

• 

Make sure air vents in control 
panel and the front lens are not 
blocked 

• 

Turn up the air conditioning 

 
LEDs damaged 

• 

Disconnect the fixture and return it 
to your dealer 

The power supply settings do not 
match local AC voltage and 
frequency 

• 

Disconnect fixture. Check settings 
and correct if necessary 

 

Summary of Contents for Eventlite 177IR

Page 1: ...EventLITE 177IR V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 44010 MANUAL ENGLISH...

Page 2: ...ve control 11 Multiple EventLITEs DMX Control 12 Fixture Linking 13 Data Cabling 13 Control Panel 14 Control Mode 14 DMX Addressing 14 Menu Overview 15 Main Menu Options 16 1 Built in programs 16 2 Au...

Page 3: ...t includes Showtec EventLITE 177IR IEC power cable 1 5 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration of...

Page 4: ...te force when installing or operating the device Only use the device indoors avoid contact with water or other liquids Only operate the fixture after having checked if the housing is firmly closed and...

Page 5: ...aximum ambient temperature ta 40 C must never be exceeded The relative humidity must not exceed 50 with an ambient temperature of 40 C If this device is operated in any other way than the one describe...

Page 6: ...h the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW CO...

Page 7: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 8: ...ging Spare battery SPTOP252 DMX channels 2 3 or 5 channels 4 digit LED display for easy setup Light source 177x 10mm 60xR 60xG 57xB LEDs Light output 700 lux 2m Color Range 16 7 million additive RGB c...

Page 9: ...8 Ordercode 44010 EventLITE 177IR Frontside Fig 01 01 Adjustment screw 02 Mounting bracket 03 177x 10mm 60xR 60xG 57xB LEDs...

Page 10: ...t all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observan...

Page 11: ...de Sound mode Master Slave DMX 512 2CH 3CH 5CH One EventLITE Built in programs Auto mode and Static color mode 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for a...

Page 12: ...Signal 04 Link the units as shown in Fig 03 Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth un...

Page 13: ...nnect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric mai...

Page 14: ...tly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic...

Page 15: ...TE correctly If two or more EventLITEs are addressed similarly they will work similarly Controlling After having addressed all EventLITEs you may now start operating these via your lighting controller...

Page 16: ...15 Ordercode 44010 EventLITE 177IR Menu Overview...

Page 17: ...grams 04 When you select menu you can choose 8 preset colors and blackout Press SETUP to enter and choose one with the UP DOWN buttons 05 Press the SETUP button again to open the next menu You can set...

Page 18: ...d control mode between from low to high sound sensitivity 04 Sound controlled mode is now active and the device will react to the beat of the background music 4 DMX Addressing DMX configuration With t...

Page 19: ...djustment Green 0 255 Gradual adjustment Blue 0 255 Strobe Frequency 0 99 and FL 05 You can combine Red Green and Blue to create an infinite range of colors 0 255 7 Eco Mode With this menu you can set...

Page 20: ...lue button Minus Decrease value button Red Activate the Red color Green Activate the Green color Blue Activate the Blue color Amber Activate the Amber color White Activate the White color Cyan Activat...

Page 21: ...ith the and buttons you can set the strobe frequency between 3 Sound controlled mode 01 Press the button to activate the Sound controlled mode 02 With the and buttons you can set the sensitivity betwe...

Page 22: ...1 100 3 channels Channel 1 Red Dimmer intensity 0 255 Gradual adjustment Red from 0 100 Channel 2 Green Dimmer intensity 0 255 Gradual adjustment Green from 0 100 Channel 3 Blue Dimmer intensity 0 25...

Page 23: ...If this happens follow the directions below 01 Unplug the unit from electric power source 02 Insert a flat headed screwdriver into a slot in the fuse cover Gently pry up the fuse cover The fuse will...

Page 24: ...ions and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link...

Page 25: ...nal output 3 pin DMX OUT Electro mechanical effects LED Quantity 177x 10mm 60xR 60xG 57xB LEDs Light output 700 lux 2m Color mixing RGB Beam angle 30 Dimmer 0 100 Strobe 0 20Hz Housing ABS plastic DMX...

Page 26: ...25 Ordercode 44010 EventLITE 177IR Dimensions...

Page 27: ...26 Ordercode 44010 EventLITE 177IR Notes...

Page 28: ...2016 Showtec...

Reviews: