Installation 

Remove all packing materials from the SDS-6. Check if all foam and plastic padding is removed. 
Connect all cables. 

Do not supply power before the whole system is set up and connected properly. 
Always disconnect from electric mains power supply before cleaning or servicing. 
Damages caused by non-observance are not subject to warranty. 

 

Set Up and Operation 

Follow the directions below, as they pertain to your preferred operation mode. 
Before plugging the unit in, always make sure that the power supply matches the product specification 
voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa. 
Connect the device to the main power supply. 
 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support.  
 

Important: 

Fixtures on a serial data link must be daisy chained in one single line. To comply with the  
EIA-485 standard no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal. 

 

Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of fixtures on a DMX data link: 30 fixtures 

 

Data Cabling 

To link fixtures together, you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 

DAP Audio DMX Data Cables 

• 

DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin. 

Ordercode

 FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m). 

 

DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. 

Ordercode

 FLX0175 (0,75 m), 

FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m).

 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®.

 Ordercode

 FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®.

 Ordercode

 FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m). 

 

DAP Audio 110 Ohm cable with digital signal transmission. 

Ordercode

 FL0975 (0,75 m), 

FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m).   

 

Control Modes 

 

 

Caution! 

 

Never connect a fixture which is operating in any stand-alone mode (either Static, Automatic, or Sound-
controlled) to a DMX string connected to a DMX controller.  
Fixtures in stand-alone mode may transmit DMX signals that could interfere with the DMX signals from the 
controller. 
 
01)

 

Slide the master dimmer fader up 

(04)

, in order to activate the master dimmer of the connected 

fixture. 

02)

 

Slide the 1-6 faders 

(06)

 in order to set the connected fixture’s DMX channels. 

 

 

Summary of Contents for DB-6i

Page 1: ...SDS 6 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50723 MANUAL ENGLISH...

Page 2: ...inations 3 Connection with the mains 4 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Installation 6 Set Up and Operation 6 Fixture Linking 6 Data Cabling 6 Control Modes 6 Mainten...

Page 3: ...Your shipment includes Showtec SDS 6 12V DC 1A power adapter 1 5 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualif...

Page 4: ...ruck disconnect mains power supply immediately Have a qualified engineer inspect for safety before operating If the device has been exposed to drastic temperature fluctuation e g after transportation...

Page 5: ...r UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your addre...

Page 6: ...ixture control Master dimmer fader DMX 512 3 pin female XLR OUT Power supply 12V DC 1A power adapter included Power consumption 1W Dimensions 170 x 149 x 51 mm LxWxH Weight 0 8 kg Overview Fig 01 01 1...

Page 7: ...mmended number of fixtures on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer dist...

Page 8: ...he steps below in sequence until a solution is found Once the unit operates properly do not carry out following steps No Light If the SDS 6 does not operate properly refer servicing to a technician Su...

Page 9: ...3 Signal output 3 pin DMX signal connector OUT Electro mechanical effects 6 channel fixture control Master dimmer fader Housing Grey metal flame retardant plastic Connections Power adapter DMX Data co...

Page 10: ...9 Ordercode 50723 SDS 6 Notes...

Page 11: ...10 Ordercode 50723 SDS 6...

Page 12: ...2015 Showtec...

Reviews: