background image

 

  

 

 

12 

   

 

Ordercode: 42595 

Compact Par 7 MKII 

Control Panel 

 

A) 

B) 

C) 

D) 

E) 

 

LCD Display  
Mode button 
Setup Button 
Up Button 
Down Button 

 

Fig.05

   

 

Control Mode  

The fixtures are individually addressed on a data-link and connected to the controller.  
The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, 
the controller will display the saved DMX address the next time.)

 

 

DMX Addressing

 

The control panel on the front side of the base allows you to assign the DMX fixture address, which is the 
first channel from which the Compact Par 7 MKII will respond to the controller. 
Please note when you use the controller, the unit has 

7

 channels. 

When using multiple Compact Pars, make sure you set the DMX addresses right. 
Therefore, the DMX address of the first Compact Pars should be 

1(d001)

; the DMX address of the second 

Compact Par 7 MKII should be 

1+7=8 (d008

); the DMX address of the third Compact Par 7 MKII should be 

8+7=15 (d015)

, etc. 

Please, be sure that you don’t have any overlapping channels in order to control each Compact Par 7 
MKII correctly. 
If two or more Compact Pars are addressed similarly, they will work similarly.

 

 

Controlling: 

After having addressed all Compact Par 7 MKII fixtures, you may now start operating these via your 
lighting controller. 

Note:

 After switching on, the Compact Par 7 MKII will automatically detect whether DMX 512 data is 

received or not. If there is no data received at the DMX-input, the “

LED

“ on the control panel will not 

flash. 
The problem may be:

 

 

The XLR cable from the controller is not connected with the input of the Compact Par 7 MKII.

 

 

The controller is switched off or defective, the cable or connector is detective, or the signal wires are 
swapped in the input connector.

 

 

Note:

 It’s necessary to insert a XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 

proper transmission on the DMX data link.  
 

 

Display Off after 10 seconds

 

 

When no button is pressed for 10 seconds, the display will turn off. 
To light up the display, you have to press the MODE, SETUP, UP or DOWN button. 
Once you have pressed the button, the display will light up. 
 

 

Summary of Contents for compact par 7 MKII

Page 1: ...Compact Par 7 MKII V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42595 MANUAL ENGLISH...

Page 2: ...mpact Pars Master Slave control 9 Multiple Compact Pars DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 1 DMX...

Page 3: ...mperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving your lifespan exp...

Page 4: ...t the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged...

Page 5: ...hers Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried...

Page 6: ...n proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 You...

Page 7: ...0 240 VAC 50 60Hz Drive current 0 68A 110V 0 32A 240V Power consumption 28W max FO full output Power linking 20pcs 110V 38pcs 240V DMX control Via standard DMX controller On Board Display for easy Set...

Page 8: ...7 Ordercode 42595 Compact Par 7 MKII Frontside Fig 01 01 Frontside Mounting bracket with Screw 02 Lens...

Page 9: ...al connector OUT NOTE Knowledge of DMX is required to fully utilize this unit Installation Remove all packing materials from the Compact Par 7 MKII Check that all foam and plastic padding is removed C...

Page 10: ...cable it functions as a stand alone device 05 Please see page 14 and 15 for more information about the manual control functions Multiple Compact Pars Master Slave control 01 Fasten the effect light o...

Page 11: ...er devices 05 Link the units as shown in figure 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourt...

Page 12: ...recommended number of Compact Pars on a DMX data link 30 fixtures Maximum recommended number of Compact Pars on a Power link 20 fixtures 110V Maximum recommended number of Compact Pars on a Power lin...

Page 13: ...Please be sure that you don t have any overlapping channels in order to control each Compact Par 7 MKII correctly If two or more Compact Pars are addressed similarly they will work similarly Controll...

Page 14: ...13 Ordercode 42595 Compact Par 7 MKII Menu Overview...

Page 15: ...lso choose the desired DMX Mode 04 Press the SETUP button to set 3 different DMX Modes Use the Up Down buttons to choose between 3 6 or 7 Channels 2 Slave Mode With this menu you can set the Master or...

Page 16: ...cy and the Program Running Speed by pressing the SETUP button 06 Use the UP DOWN buttons to change the values Speed from 01 99 and FL Flash Frequency from 00 99 5 Manual Color control With this menu y...

Page 17: ...0 100 6 Channels Channel 1 Dimmer Colors RGB must be open 0 255 From black to brightest Channel 2 Red Dimmer intensity CH1 must be set between 0 255 0 255 Red from 0 100 Channel 3 Green Dimmer intens...

Page 18: ...ity CH1 must be set between 0 255 0 255 Blue from 0 100 Channel 5 Built in Programs 0 24 No function 25 49 Built in Program 01 50 74 Built in Program 02 75 99 Built in Program 03 100 124 Built in Prog...

Page 19: ...technical installations are to be inspected by a skilled person once a year The following points have to be considered during the inspection 01 All screws used for installing the device or parts of th...

Page 20: ...II as this may damage the unit and the warranty will become void 06 Return the device to your Showtec dealer No Response to DMX Response Suspect the DMX cable or connectors a controller malfunction a...

Page 21: ...n Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fix...

Page 22: ...ned housing ensures an optimum heat dissipation during operation Mounting Multiple mounting possibilities DMX control Via standard DMX controller On Board Display for easy Set Up Control DMX 512 Built...

Page 23: ...22 Ordercode 42595 Compact Par 7 MKII Dimensions c...

Page 24: ...2015 Showtec...

Reviews: