SHOWTEC Beacon 360 V2 Manual Download Page 10

 

  

 

 

   

 

Ordercode: 45051 

Beacon 360 

Control Modes 

 
There are 5 modes: 

 

Built-in programs (stand-alone) 

 

 

Manual mode Built-in programs (stand-alone) 

 

 

Sound-controlled 

 

 

Master/Slave 

 

 

DMX-512 (9CH, 20CH) 

 

One Beacon (Stand-alone and Manual) 

01)

 

Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation. 

02)

 

Always use a safety cable (ordercode 70140 / 70141). 

03)

 

Plug the end of the electric mains Powercon cord into a proper electric power supply socket. 

04)

 

When the Beacon is not connected with a DMX cable, it functions as a stand-alone device. 

05)

 

Please see page 14 for more information about the Built-in auto programs and page 15 for more 
information about the Manual mode. 

 

One Beacon (Sound-controlled) 

01)

 

Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation. 

02)

 

Always use a safety cable (ordercode 70140 / 70141). 

03)

 

Plug the end of the electric mains Powercon cord into a proper electric power supply socket. 

04)

 

When the Beacon is not connected with a DMX cable, it functions as a stand-alone device. 

05)

 

Please see page 16 for more information about the Sound-controlled mode.  

 

Multiple Beacons (Master/Slave Mode) 

01)

 

Fasten the effect light onto firm trussing. Leave at least 0,5 meter on all sides for air circulation. 

02)

 

Always use a safety cable (ordercode 70140 / 70141). 

03)

 

Plug the end of the electric mains Powercon cord into a proper electric power supply socket. 

04)

 

Use a 3-pin XLR cable to connect the Beacons.   
 

 

The pins: 

 

 

01) Earth 

 

02) Signal (-) 

 

03) Signal (+) 

05)

 

Link the units as shown in Fig. 03, connect a DMX signal cable from the first unit's DMX "out" socket to 
the second unit's "in" socket. Repeat this process to link the second, third, and fourth units. You can 
use the same functions on the master device as described on pages 14 and 16 (Built-in or Sound-
controlled). This means on the master device you can set your desired operation mode and all slave 
devices will react the same as the master device. 
 

Multiple Beacons Master/Slave Set Up 

 

 

Fig. 03 

 

 

Summary of Contents for Beacon 360 V2

Page 1: ...Beacon 360 V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 45051 MANUAL ENGLISH...

Page 2: ...eacons DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 1 DMX 512 Mode 14 2 Channel Mode 14 3 Built in auto pr...

Page 3: ...is decline Packaged in clusters LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of...

Page 4: ...tilation Always disconnect power from the mains when device is not used or before cleaning Only handle the power cord holding it by the plug Never pull out the plug by tugging the power cord Make sure...

Page 5: ...own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always l...

Page 6: ...he device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLA...

Page 7: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 8: ...9 20 Channels 360 pan and 360 tilt Colors Red Green Blue White Control modes DMX 512 Auto Manual Master Slave Sound Metal Flame retardant plastic housing DMX Data IN OUT Pro power connector IN OUT Bl...

Page 9: ...ng is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages ca...

Page 10: ...lectric mains Powercon cord into a proper electric power supply socket 04 When the Beacon is not connected with a DMX cable it functions as a stand alone device 05 Please see page 16 for more informat...

Page 11: ...he Beacons and other devices 05 Link the units as shown in Fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second...

Page 12: ...splitter may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of fixtures on a DMX data link 30 fixtures Data Cabling...

Page 13: ...ddress of the second Beacon should be 1 20 21 021 the DMX address of the third Beacon should be 20 20 41 041 etc Please make sure that you do not have any overlapping channels in order to control each...

Page 14: ...13 Ordercode 45051 Beacon 360 Menu Overview...

Page 15: ...03 Press the UP and DOWN buttons to set the DMX address between 04 Press the SETUP button to confirm the address 2 Channel Mode 01 While in the main menu press the UP and DOWN buttons until the displ...

Page 16: ...djust the tilt movement settings between The values correspond with their DMX counterparts 07 Press the SETUP button to store changes 08 When the display shows press the SETUP button to enter the menu...

Page 17: ...de OFF Sound Sensitivity settings 04 Press the SETUP button to confirm your choice 05 When the display shows press the SETUP button to enter the sound sensitivity menu 06 Press the UP and DOWN buttons...

Page 18: ...main menu press the UP and DOWN buttons until the display shows 02 Press the SETUP button to look up the currently installed software version 11 Restoration of Factory Settings 01 While in the main me...

Page 19: ...255 Counterclockwise rotation from slow to fast Channel 3 Dimmer 0 255 Dimmer intensity from OFF to full ON Channel 4 Red color 0 255 Red color intensity from OFF to full ON Channel 5 Green color 0 2...

Page 20: ...en 0 360 128 191 Clockwise rotation from fast to slow 192 255 Counterclockwise rotation from slow to fast Channel 8 Red color LED 1 0 255 Red color intensity from OFF to full ON Channel 9 Green color...

Page 21: ...6 95 Color switch effect 2 96 135 Color switch effect 3 136 175 Color switch effect 4 176 215 Color switch effect 5 216 255 Color flow Channel 19 Color Switch Speed CH18 must be set between 16 215 0 2...

Page 22: ...not function whatsoever If this happens follow the directions below 01 Unplug the unit from electric power source 02 Insert a flat headed screwdriver into a slot in the fuse cover and turn The fuse wi...

Page 23: ...ns and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link In...

Page 24: ...rd DMX controller Reverse Pan Tilt movement Special Pan Tilt movement Pan 0 360 Tilt 0 360 Control modes DMX 512 Auto Manual Master Slave Sound Colors Red Green Blue White Color functions Rainbow effe...

Page 25: ...24 Ordercode 45051 Beacon 360 Dimensions...

Page 26: ...25 Ordercode 45051 Beacon 360 Notes...

Page 27: ...26 Ordercode 45051 Beacon 360...

Page 28: ...2015 Showtec...