10
The Adrenaline can be operated with a controller in
control mode
or without the controller in
stand-alone
mode.
Control Panel
Fig. 5
A.
LCD Display
D.
Up Button
B.
MODE button
E.
Down Button
C.
SETUP Button
DMX Control Mode
The fixtures are individually addressed
on a data-link and connected to the
controller.
The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it,
the controller will display the saved DMX address the next time.)
DMX Addressing
The control panel on the front side of the Adrenaline allows you to assign the DMX fixture address, which
is the first channel from which the Adrenaline will respond to the controller.
Please note when you use the controller, the unit has
4
channels.
When using multiple Adrenalines, make sure you set the DMX addresses right.
Therefore, the DMX address of the first Adrenaline should be
1(A001)
; the DMX address of the second
Adrenaline should be
1+4=5 (5
); the DMX address of the third Adrenaline should be
5+4=9 (9)
, etc.
Please, be sure that you don’t have any overlapping channels in order to control each Adrenaline
correctly.
If two or more Adrenalines are addressed similarly, they will work similarly.
For address settings, please refer to the instructions under ”Addressing’ (menu
)
Controlling:
After having addressed all Adrenaline fixtures, you may now start operating these via your lighting
controller.
Note:
After switching on, the Adrenaline will automatically detect whether DMX 512 data is received or
not.
If there is
no data received at the DMX-input, the “
LED
“ on the control panel will not flash.
The problem may be:
- The XLR cable from the controller is not connected with the input of the Adrenaline.
- The controller is switched off or defective, the cable or connector is detective, or the signal wires are
swapped in the input connector.
Note:
It’s necessary to insert a XLR termination plug (with 120 Ohm) in the last fixture in order to ensure
proper transmission on the DMX data link.