SHOWTEC 51336 Product Manual Download Page 14

12 

 

Multiple Galactic GBC-120 (

DMX Control

)

 

1.

 

Fasten the effect light onto firm trussing 

Leave at least 1 meter on all sides for air circulation. 

2.

 

Always use a safety cable (ordercode 70140 / 70141). 

3.

 

Use a 3-p XLR cable to connect the Galactic GBC-120 lasers.

 

4.

 

Link the units as shown in (figure 4), Connect a DMX signal cable from the first unit's DMX "out" socket 
to the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.

 

5.

 

Supply electric power: Plug the end of the mains power cord into proper electric power supply 
sockets. Do so for all units and the controller. 

 

Multiple Galactics Set Up

 

 

 
 
 
 
 
 
 
 

     Max. 30 Galactics

 

 

Fig. 4

 

 

 

Note : Link all DMX cables and set dip switches before connecting electric power 

 

6.

 

Do not supply power before the whole system is set up and connected properly. Design your show 
according to your DMX controller functions. See page 15 for more about DMX programming.

 

 
 

Fixture Linking

 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support.   
 
 

Important:

  

Fixtures on a serial data link must be daisy chained in one single line. To comply with the  
EIA-485 standard no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal. 
 
Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of Galactics on a DMX data link: 30 fixtures 
 

 

Data Cabling 

To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 

DAP Audio Certified DMX Data Cables 

 

DAP Audio Basic microphone cable for allround use. 

bal. XLR/M 3 p. > XLR/F 3 p.  

Ordercode

 FL01150 (1,5m.), FL013 (3m.), FL016 (6m.), FL0110 (10m.), FL0115 (15m.), FL0120 (20m.). 

 

DAP Audio cable f

or the demanding user with exceptional audio-qualities and connector made by  

Neutrik®.

 Ordercode

 FL71150 (1,5m.), FL713 (3m.), FL716 (6m.), FL7110 (10m.). 

 

Summary of Contents for 51336

Page 1: ...Galactic GBC 120 ORDERCODE 51336 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Page 2: ...gn and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant show...

Page 3: ...1 One Galactic RGY 140 Sound control 11 Multiple Galactics Master Slave control 11 Multiple Galactic RGY 140 DMX Control 12 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addr...

Page 4: ...n and maintenance of this device have to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should there...

Page 5: ...o extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the powe...

Page 6: ...ntification Laser Classification Class IIIB Cooling TE Cooling Laser medium wavelength 532 nm Green DPSS Medium DPSS Nd YVO4 40mW wavelength 450 nm Blue DPSS Medium LD GeAs 80mW Output 120mW Beam Diam...

Page 7: ...hort circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other s...

Page 8: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Page 9: ...es Laser Class IIIB Laser Safety EN IEC 60825 1 Ed 2 2007 03 Laser Color Green Blue Cyan Laser Power 120mW 40mW 532nm Green 80mW 450nm Blue Scan Angle 30 Scan Speed Stepping motor Control Modes Auto S...

Page 10: ...11 12 1 Mountingbracket with adjustment screw 7 Earth connection 2 3 pin DMX Out 8 Remote Control 3 ON OFF 9 Lock On Off 4 Fuse 1A 250V 10 Safety Eye 5 IEC Powerconnector 11 LCD Display Menu Buttons 6...

Page 11: ...hen sound signal is detected During a sound controlled Show press MUSIC B 1 9 to set the sensitivity 9 is the most sensitive COLOR CHANGE Cycle through the pre programmed colors PATTERN CHANGE To show...

Page 12: ...d safety keys are included in the box The interlock is the included in the box successor for the optional remote interlock 51316 They should be kept with the Galactic GBC 120 laser The following safet...

Page 13: ...t of the music Please see page 16 for more information about the sound control options Multiple Galactics Master Slave control 1 Fasten the effect light onto firm trussing Leave at least 1 meter on al...

Page 14: ...erating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link mus...

Page 15: ...ic GBC 120 should be 1 10 11 the DMX address of the third Galactic GBC 120 should be 11 10 21 etc Please be sure that you don t have any overlapping channels in order to control each Galactic GBC 120...

Page 16: ...14 Menu Overview The Galactic GBC 120 will only show its version number at start up...

Page 17: ...s from 3 Use the ENTER button to store your setting 2 Slave Mode With this menu you are able to set the device as a slave device 1 Press the FUNC button until the display shows 2 Use the ENTER button...

Page 18: ...o select 4 Use the ENTER button to store your setting 6 Sensitivity Mode With this menu you can set the Audio Sensitivity 1 Press the FUNC button until the display shows 2 You can choose 10 different...

Page 19: ...175 199 Blue Cyan 200 224 Blue Green Cyan 225 255 Color flow Channel 4 Color Changing Speed when CH3 is set between 125 255 0 4 Stop 5 255 Color changing speed from slow to fast Channel 5 Zoom 0 127...

Page 20: ...0 359 degree fixed X Axis rolling 128 191 Counterclockwise rotation from slow to fast 192 255 Clockwise rotation from slow to fast Patterns 000 007 064 071 128 135 192 199 008 015 072 079 136 143 200...

Page 21: ...own or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and specification See the product sp...

Page 22: ...efective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination...

Page 23: ...120mW 40mW 532nm Green 80mW 450nm Blue Scan Angle 30 Scan Speed Stepping motor Control Modes Auto Sound Master Slave DMX 3 pin DMX In and 3 pin DMX Out Clear LCD display for all settings Compact stro...

Page 24: ......

Reviews: