background image

 

  

 

 

   

 

Ordercode: 50665 

 

Showtec PSA-32A12M 

 

 

Multiconnector outputs pin assignment 

 

 

Fig.03

 

 

Maintenance 

The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test. 
The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by a skilled person once a year. 
 

We strongly advise you to let a qualified technician give the unit a maintenance check twice a year. 

The following points have to be considered during the inspection: 
01)

 

All screws used for installing the device or parts of the device have to be tightly connected and 
must not be corroded. 

02)

 

There may not be any deformations on housings, fixations and installation spots. 

03)

 

The electric power supply cables must not show any damages or material fatigue. 

 
The Showtec PSA-32A12M requires almost no maintenance. However, you should keep the unit clean.  

01)

 

Disconnect the mains power supply, and then wipe the cover with a damp cloth. Do not immerse in 
liquid. Do not use alcohol or solvents. 

02)

 

Please clean internal components twice a year with a light brush and vacuum cleaner. 

03)

 

Keep connections clean. Disconnect electric power, and then wipe the connections with a damp 
cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric 
power. 

04)

 

Check and tighten all screws, especially the screw terminals.

 

05)

 

The electric power supply cables must not show any damages or material fatigue. 

 

Troubleshooting 

This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps 
below in sequence until a solution is found. Once the unit operates properly, do not carry out the 
following steps. 
01)

 

If the device does not operate properly, unplug the device. 

02)

 

Check power from the wall and all cables. 

03)

 

Plug the unit in again. 

04)

 

If nothing happens after 30 seconds, unplug the device. 

05)

 

Return the device to your Showtec dealer. 

 

 

Summary of Contents for 50665

Page 1: ...Showtec PSA 32A12M V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50665 MANUAL ENGLISH...

Page 2: ...terminations 4 Connection with the Three Phase Power Network 4 Return Procedure 5 Claims 5 Description of the device 6 Frontside 6 Backside 7 Installation 8 Set Up and Operation 8 Multiconnector outpu...

Page 3: ...king Your shipment includes Showtec PSA 32A12M with the power cable 1 5 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be...

Page 4: ...not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device...

Page 5: ...oduct may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others C...

Page 6: ...e number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this...

Page 7: ...output on the rear panel 2 x Multipin 6x10A on the rear panel 12 x 1 pin 16A C Type circuit breaker MCB A Type 30 mA Residual Current Circuit breaker RCCB Housing Material Powder coated metal Color D...

Page 8: ...splay 08 L3 voltage amperage LED display Backside Fig 02 09 Schuko output Maximum load 16A Total load for all sockets on L1 together should not exceed 32A per phase 10 Schuko output Maximum load 16A T...

Page 9: ...ment into a 19 inch rack Connect all cables Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Oper...

Page 10: ...lmost no maintenance However you should keep the unit clean 01 Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immerse in liquid Do not use alcohol or solvents 02 Pl...

Page 11: ...ko socket P N PE Circuit breaker MCB 12 x 1 pin 16A C Type Residual Current Circuit breaker RCCB 30 mA A Type Electro mechanical effects IP Rating IP20 Housing Road suited Components Road suited Housi...

Page 12: ...11 Ordercode 50665 Showtec PSA 32A12M Dimensions...

Page 13: ...12 Ordercode 50665 Showtec PSA 32A12M Notes...

Page 14: ...13 Ordercode 50665 Showtec PSA 32A12M...

Page 15: ...14 Ordercode 50665 Showtec PSA 32A12M...

Page 16: ...2016 Showtec...

Reviews: