Ordercode: 50660 

 

PSA-16A3C 

 

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The maximum ambient temperature 

t

a

 = 35°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 35° C. 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the

 

warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 

 

You endanger your own safety and the safety of others!

 

 
 

Connection with the Three Phase Power Network

 

Connect the device to the 3-phase Power Socket with a CEE-form power-plug. 
Always make sure that the right color cable is connected to the right place. 
 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

L1 

BROWN

 

RED

 

BLACK

 

PHASE 1

 

L2 

BLACK 

YELLOW 

RED 

PHASE 2 

L3 

GREY 

BLUE 

BLUE 

PHASE 3 

BLUE 

BLACK 

WHITE 

NEUTRAL 

 

YELLOW/GREEN 

GREEN 

GREEN 

PROTECTIVE GROUND 

 

Make sure that the device is always connected 

properly 

to the earth! 

 

Improper installation can cause serious injuries to people and/or damage of property ! 

 

 

Summary of Contents for 50660

Page 1: ...PSA 16A3C V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50660 MANUAL ENGLISH...

Page 2: ...Instructions 2 Operating Determinations 4 Connection with the Three Phase Power Network 4 Return Procedure 5 Claims 5 Description of the device 6 Frontside 6 Backside 7 Installation 8 Set Up and Opera...

Page 3: ...ox and packing Your shipment includes Showtec PSA 16A3C User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow...

Page 4: ...exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and...

Page 5: ...Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Connection with the Three Phase Power Network Connect t...

Page 6: ...ber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this chec...

Page 7: ...to the three phase mains Make sure that the total load connected to the PSA 16A3C does not exceed 16A per phase The CEE input should be connected to the power source which is equipped with its own RCC...

Page 8: ...side should not exceed 16A per phase 11 CEE L2 Output 3 pin CEE socket Maximum load 1x 16A per socket Total load for both sockets on L2 together should not exceed 16A per phase 12 CEE L2 Output 3 pin...

Page 9: ...s have to be considered during the inspection 01 All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformat...

Page 10: ...0V AC 50 60Hz Circuit breaker 3 x 1 pin 16A C Type Electro mechanical effects IP rating IP20 Housing Powder coated metal Rated current 16A Breaking capacity 6kA Color Dark grey Voltage and amperage in...

Page 11: ...10 Ordercode 50660 PSA 16A3C...

Page 12: ...2016 Showtec...