Rigging
The device can be positioned on a flat surface or mounted to a truss or other rigging structure. Make sure
that all loads are within the pre-determined limits of the supporting structure.
CAUTION
Restrict the access under the work area during rigging and/or derigging.
To mount the device, follow the steps below:
01)
Use a clamp to attach the device to the supporting structure, as shown in Fig. 05. Make sure that the
device cannot move freely. The use of a quick lock bracket is optional.
02)
Secure the device with a secondary suspension, for example a safety cable. Make sure that the
secondary suspension can hold 10 times the weight of the device. If possible, the secondary
suspension should be attached to a supporting structure independent of the primary suspension. Put
the safety cable through the safety eye (05), as shown in Fig. 05.
Fig. 05
Angle Adjustment
You can adjust the angle of the device.
Tilt the device to the desired angle (see Fig. 06). The tilt range is <180°.