8
Data Cabling
To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic
interference.
DAP Audio Certified DMX Data Cables
• DAP Audio Basic microphone cable for allround use.
bal. XLR/M 3 p. > XLR/F 3 p.
Ordercode
FL01150 (1,5m.), FL013 (3m.), FL016 (6m.), FL0110 (10m.), FL0115 (15m.), FL0120 (20m.).
• DAP Audio cable f
or the demanding user with exceptional audio-qualities and connector made by
Neutrik®.
Ordercode
FL71150 (1,5m.), FL713 (3m.), FL716 (6m.), FL7110 (10m.).
One Mini Max LED RGB
1.
Fasten the moving head onto firm trussing (Use a proper clamp fastened onto the
Mini Max LED RGB).
Leave at least 1 meter on all sides for air circulation.
2.
Plug one end of the electric mains power cord into the IEC socket on the unit
.
Then plug the other end of the cord into a proper electric power supply socket.
3.
To set the program to be played, see page 9 for the menu settings
Multiple Mini Maxs LED RGB
1.
Fasten the effect light onto firm trussing (Use a proper clamp fastened onto the
Mini Max LED RGB).
Leave at least 1 meter on all sides for air circulation.
2.
Use a 3-p XLR cable to connect the
Mini Max LED RGB
and other devices.
3.
Link the units as shown in (figure 3), Connect a DMX signal cable from the first unit's DMX "out" socket to
the second unit's "in" socket. Repeat this process to link the second, third, and fourth units.
4.
Supply electric power: Plug electric mains power cords into each unit's IEC socket, then plug the other
end of the mains power cord into proper electric power supply sockets, starting with the first unit.
Do not supply power before the whole system is set up and connected properly.
Multiple Mini Max LED RGB Set Up
Fig. 3
Note : Link all cables before connecting electric power