DMX Dip Switch Value Guide 

DMX products must have their own "address" to receive DMX signals. 
Addresses on the controller are set by flipping the appropriate DMX Dip switches. 

 

 

 

You need to know that DMX address settings are the sum of the dip switch values. 
A standard DMX address for a Showtec Star Sky, which has 5 channels is as follow: 
 

Example 

 

Star Sky 

 Address Value  

DMX Dip Switches "ON" 

Unit 5    

   21 

 

 

 

 #1 , #3, #5 

 
Switch   

Value 

    #1   

     1 

    #3   

     4 

    #5   

   16  + 

Total sum 

   21 

Explanation: Since each unit has 5 channels, each address advances 5 values (See Address Value 
above). 

Once address values are determined, add DMX dip switch values to obtain the appropriate address 
(DMX Dip Switches "ON") for each unit. Flip appropriate DMX dip switches on each unit. 
 
 

Maintenance 

The Showtec Star Sky 2

 

requires almost no maintenance. However, you should keep the unit clean. 

Otherwise, the fixture’s light-output will be significantly reduced. 

Disconnect the mains power supply, and 

then wipe the cover with a damp cloth. Do not immerse in liquid. 

The housing will require monthly 

cleaning, as smoke-fluid tends to build up residues, reducing the light-output very quickly. 

Do not use alcohol or solvents. Keep connections clean. Disconnect electric power, and then wipe the 
connections with a damp cloth. Make sure connections are thoroughly dry before linking equipment or 
supplying electric power. 

 

The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by an expert after every four years in the course of an acceptance test. 
The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by a skilled person once a year. 
 
The following points have to be considered during the inspection: 

1. 

All screws used for installing the device or parts of the device have to be tightly connected and must  

    not be corroded.

 

2. 

There may not be any deformations on housings, fixations and installation spots.

 

3. 

The electric power supply cables must not show any damages or material fatigue.

 

 

Replacing a Fuse 

Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the 
fuse burns out, the product will not function whatsoever. If this happens, 

follow the directions below to do 

so.

 

1.

 Unplug the unit from electric power source. 

2.

 Insert a flat-head screwdriver into a slot in the fuse cover. Turn the screwdriver to the left, at the same  

    time gently push a bit (Turn and Push). The fuse will come out. 

3.

 Remove the used fuse. If brown or unclear, it is burned out. 

4.

 Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to  

    use a fuse of the same type and specification. See the product specification label for details.

 

Summary of Contents for 40343

Page 1: ...Colour Star Sky II DMX V4 ORDERCODE 40343...

Page 2: ...and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant showtec...

Page 3: ...e Warning Safety instructions Operating Determinations Rigging Return Procedure Claims Description Features Set Up and Operation DMX Channels Controller DMX Dip Switch Value Guide Maintenance Replacin...

Page 4: ...000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may inc...

Page 5: ...ned pressed together or heated The cable insert or the female part in the device must never be strained There must always be sufficient cable to the device Otherwise the cable may be damaged which may...

Page 6: ...and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure T...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...EDs 40342 or Coloured LEDs 40343 192 LEDs Overview Fig 1 Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sure...

Page 9: ...Dimmer of Channel 4 5 6 or 7 must be open 0 20 Stop 21 255 Strobe Speed of LED group 1 2 3 and 4 Channel 4 Red Dimmer intensity LED Group 1 0 255 From black to brightest Channel 5 Yellow Dimmer intens...

Page 10: ...onnections are thoroughly dry before linking equipment or supplying electric power The operator has to make sure that safety relating and machine technical installations are to be inspected by an expe...

Page 11: ...nectors a controller malfunction a light effect DMX card malfunction 1 Check the DMX cable Unplug the unit change the DMX cable then reconnect to electrical power Try your DMX control again 2 Determin...

Page 12: ......

Reviews: