SHOWTEC 40159 Manual Download Page 4

 

  

 

 

   

 

Ordercode: 40158 

XS-1 RGBW 

 
This device contains no user-serviceable parts. Refer to qualified technicians only. 
 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device.

 

 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never lift the fixture holding it by the projector-head, as the mechanics may be damaged.  
Always hold the fixture by the transport handles. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Never loosen the screws of the gobo, otherwise you risk opening of the ball bearing. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot). 
Allow the fixture to cool for at least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use the device indoors, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the case closed while operating. 

 

Always allow a free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord holding it by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device.  
Leave the device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The moving head must be installed beyond the reach of children. Never leave the 
unit running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the XS-1 RGBW. The manufacturer will 
not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

During the initial start-up some smoke or smell may arise. This is a normal process and does not 
necessarily mean that the device is defective. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

Summary of Contents for 40159

Page 1: ...XS 1 RGBW V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40159 MANUAL ENGLISH...

Page 2: ...ol 9 Multiple XS 1 moving heads DMX Control 10 Fixture Linking 11 Data Cabling 11 Control Panel 12 Control Mode 12 DMX Addressing 12 Menu Overview 13 Main Menu Options 14 1 DMX Addressing 15 2 Channel...

Page 3: ...decline Packaged in clusters LEDs exhibit higher operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the...

Page 4: ...lation Always disconnect power from the mains when device is not used or before cleaning Only handle the power cord holding it by the plug Never pull out the plug by tugging the power cord Make sure t...

Page 5: ...own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always...

Page 6: ...ct the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE...

Page 7: ...r 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check...

Page 8: ...onsumption 25W max at full output Beam Angle 3 Light Source 1x10W RGBW On Board Auto Sound control Master Slave Control Protocol DMX512 9 or 16 DMX Channels Display 4 digits LED Optical system Dimmer...

Page 9: ...not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subje...

Page 10: ...ic If the device is set to sound control then the XS 1 RGBW will react to the music beats Please see page 15 for more information about the sound control options Multiple XS 1 moving heads Master Slav...

Page 11: ...devices 05 Link the units as shown in Fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth uni...

Page 12: ...ou must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade c...

Page 13: ...e second XS 1 moving head should be 1 16 17 A017 the DMX address of the third XS 1 moving head should be 17 16 33 A033 etc Please be sure that you don t have any overlapping channels in order to contr...

Page 14: ...13 Ordercode 40158 XS 1 RGBW Menu Overview...

Page 15: ...8 XS 1 RGBW Main Menu Options DMX address Channel Mode Master Slave Auto Sound controlled Sound Sensitivity Blackout LED Display Display Invert Pan Invert Tilt Invert Manual Mode Test Hours Used Firmw...

Page 16: ...n buttons until the display shows 02 Press the ENTER button to open this menu 03 Use the UP DOWN buttons to toggle between the following Auto modes Master mode Normal slave mode Mirror slave mode 04 P...

Page 17: ...shows 02 Press the ENTER button to open this menu 03 If the device has been set to ON the display is always ON 04 If the device has been set to OFF the display is OFF after 10 seconds 05 Press the SET...

Page 18: ...s menu you can view how long your XS 1 has been used 01 Press the MENU button and then the Up Down buttons until the display shows 02 Press the ENTER button to open this menu 03 The XS 1 will now show...

Page 19: ...rom slow to fast 132 139 Shutter open 140 181 Fast Close to slow Open from slow to fast 182 189 Shutter open 190 231 Slow Close to Fast Open slow Open from slow to fast 232 239 Shutter open 240 247 Ra...

Page 20: ...acro 0 15 Not used 16 35 Color Macro 1 36 55 Color Macro 2 56 75 Color Macro 3 76 95 Color Macro 4 96 115 Color Macro 5 116 135 Color Macro 6 136 155 Color Macro 7 156 175 Color Macro 8 176 195 Color...

Page 21: ...for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformations on housings fixations and installation spots 03 Mechanicall...

Page 22: ...nit operates properly do not carry out following steps If the light effect does not operate properly refer servicing to a technician Response Suspect three potential problem areas as the power supply...

Page 23: ...ed with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and...

Page 24: ...asy with only one bracket Strong narrow RGBW beam Compact housing Beam Angle 3 DMX control via standard DMX controller Light Source 1x10W RGBW On Board Auto Sound control Master Slave Control Protocol...

Page 25: ...24 Ordercode 40158 XS 1 RGBW Dimensions...

Page 26: ...25 Ordercode 40158 XS 1 RGBW Notes...

Page 27: ...26 Ordercode 40158 XS 1 RGBW...

Page 28: ...2015 Showtec...

Reviews: