background image

 

 

 

24 

 

  

 

 

Performer 2000 RGBAL 

Product code: 33038 

 

 

 

 

Main Menu Options 

The main menu has the following options: 

 

 

Press the UP/DOWN buttons to navigate through the main menu. 

02)

 

Press the ENTER button to open the submenus. 

Note: Some of the submenus require a password. The default password is pressing the UP/DOWN buttons 
in the following order: UP, DOWN, UP, DOWN, ENTER. Deactivating the display lock does not affect the 
submenu items which by default require a password. 

 

 

Summary of Contents for 33038

Page 1: ...Performer 2000 RGBAL Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Product code 33038 USER MANUAL ENGLISH V3...

Page 2: ...sposal of the device Non observance of the instructions in this user manual may result in serious injuries and damage of property 2022 Showtec All rights reserved No part of this document may be copie...

Page 3: ...r Installation 13 Personal Protective Equipment 13 Installation Site Requirements 13 Rigging 14 Angle Adjustment 15 Color Frame Retaining Clip 15 Connecting to Power Supply 16 Power Linking of Multipl...

Page 4: ...10 Channels 13 Channels 19 Channels 37 RDM Information 39 RDM Details 39 Supported RDM PIDs Parameter IDs 39 Highlite RDM Details 39 7 Troubleshooting 40 8 Maintenance 41 Safety Instructions for Main...

Page 5: ...d for general lighting Any other use not mentioned under intended use is regarded as non intended and incorrect use Product Lifespan This device is not designed for permanent operation Disconnect the...

Page 6: ...ult in minor or moderate injury Attention Indicates important information for the correct operation and use of the product Important Read and observe the instructions in this document Electrical hazar...

Page 7: ...sed and all screws are tightly fastened Disconnect the device from electrical power supply before service and maintenance and when the device is not in use DANGER Electric shock caused by short circui...

Page 8: ...s Contact your Highlight International dealer for more information as servicing can be performed only by instructed or skilled persons If the device is dropped or struck disconnect the device from the...

Page 9: ...ordinary persons Maintenance may be carried by ordinary persons Installation and service shall be carried out only by instructed or skilled persons Contact your Highlite dealer for more information In...

Page 10: ...t projects a bright soft field of light within a 15 45 motorised zoom range The Performer 2000 RGBAL features a 5 colour LED Engine RGB Amber and Lime with 16 preset colours Its 0 100 DMX controllable...

Page 11: ...w Fig 03 100 240V Pro power connector Blue IN 3 pin DMX signal connector IN 5 pin DMX signal connector IN 3 pin DMX signal connector OUT 5 pin DMX signal connector OUT 100 240V Pro power connector Gra...

Page 12: ...Manual mode Static Color presets Master Slave Manual mode Static Color presets DMX 512 RDM DMX channels HSIC 8 channels SSP 10 channels TOUR 13 channels TR16 19 channels Control panel OLED display and...

Page 13: ...ssories The Performer 2000 RGBAL is delivered without accessories You can additionally purchase the following accessories Product code 33041 Barndoor for Performer 2000 RGBAL Product code 33042 Filter...

Page 14: ...e Equipment During installation and rigging wear personal protective equipment in compliance with the national and site specific regulations Installation Site Requirements The device can be used only...

Page 15: ...w the steps below 01 Use a clamp to attach the device to the supporting structure as shown in Fig 07 Make sure that the device cannot move freely Optionally you can use the Slide Complete to attach th...

Page 16: ...ew 03 is tightened Fig 08 Color Frame Retaining Clip The color frame holder is equipped with a spring loaded retaining clip This prevents color frames and accessories from falling out 01 Release the r...

Page 17: ...er can be relayed to another device via the power OUT connector Note that the input and the output connectors have different designs one type cannot be connected to the other Power linking of multiple...

Page 18: ...shows of two or more devices set in a master slave operating mode The Performer 2000 RGBAL has 3 pin and 5 pin DMX signal IN and OUT connectors The pin assignment is as follows 3 pin pin 1 ground pin...

Page 19: ...pins and wires correctly as shown in Fig 12 Fig 12 Master Slave Setup The Performer 2000 RGBAL supports master slave control mode To connect multiple devices in master slave setup follow the steps bel...

Page 20: ...u set the DMX starting address of each device correctly The Performer 2000 RGBAL has 4 personalities 8 channels 10 channels 13 channels and 19 channels If you want to connect multiple devices on one d...

Page 21: ...mode Static Preset Color DMX 512 RDM 8 10 13 19 channels For more information about how to connect the devices refer to 5 Setup on pages 17 19 To operate the device manually as a stand alone device o...

Page 22: ...nual Mode on page 25 for more information Start up Upon start up the display will show a splash screen with the logo of Showtec the display will show information about the device s current status Pres...

Page 23: ...22 Performer 2000 RGBAL Product code 33038 Menu Overview...

Page 24: ...23 Performer 2000 RGBAL Product code 33038...

Page 25: ...s to navigate through the main menu 02 Press the ENTER button to open the submenus Note Some of the submenus require a password The default password is pressing the UP DOWN buttons in the following or...

Page 26: ...Press the UP DOWN buttons to select the desired manual mode 1 4 Press the ENTER button to activate the previously chosen mode Mode 1 In this menu you can set the dimmer zoom and CCT 01 Turn the contr...

Page 27: ...13 R377 R80 L202 L328 R3314 L101 L768 Mode 3 In this menu you can set the hue saturation and intensity 01 Turn the controls F G H to adjust settings 02 The adjustment ranges are F Hue 0 100 G Saturati...

Page 28: ...s 0 255 from low to high intensity GREEN Set the intensity of the green color The adjustment range is 0 255 from low to high intensity BLUE Set the intensity of the blue color The adjustment range is...

Page 29: ...01 While in main menu press the UP DOWN buttons until the display shows ADDRESS 02 Press the ENTER button to open the menu 03 Press the UP DOWN buttons to set the desired DMX starting address The adj...

Page 30: ...DMX Address 001 503 TOUR 13 channels DMX Address 001 500 TR16 19 channels DMX Address 001 494 02 Press the ENTER button to confirm your choice See pages 36 38 for the DMX channel modes Settings In thi...

Page 31: ...peration was completed successfully the master and the slave devices will light in green Reset In this submenu you can restore the default factory settings and reset the custom programs Select RESET a...

Page 32: ...n Select PERFORMANCE and press the ENTER button to open the submenu Press the UP DOWN buttons to choose the desired performance mode The available options are LIVE Default mode It provides a compromis...

Page 33: ...ble options are 600 Hz 1200 Hz 2000 Hz 4000 Hz 6000 Hz and 25000 Hz Note The higher the PWM frequency the lower the dimmer s grayscale Press the ENTER button to set the value Power CCT In this menu yo...

Page 34: ...rd is pressing the UP DOWN buttons in the following order UP DOWN UP DOWN ENTER OFF the main menu remains unlocked after the display turns off Note Deactivating the display lock does not affect the su...

Page 35: ...of the red color The adjustment range is 0 255 from low to high intensity GREEN Set the intensity of the green color The adjustment range is 0 255 from low to high intensity BLUE Set the intensity of...

Page 36: ...ime current software version and the RDM details of the device 01 Press the UP DOWN buttons to select one of the following 2 options VERSION RDM 02 Press the ENTER button to confirm your choice Versio...

Page 37: ...111 130 4200K 131 150 4500K 151 170 5600K 171 190 6000K 191 210 6500K 211 230 7200K 231 255 8000K 6 Strobe 000 009 No function 010 099 Strobe from low to high frequency 0 25 Hz 100 109 No function 110...

Page 38: ...0 100 7 7 13 Color Presets 000 010 No function 011 020 L106 021 030 R05 031 040 L194 041 050 R54 051 060 L019 061 070 R08 071 080 R89 081 090 R86 091 100 L213 101 110 R377 111 120 R80 121 130 L202 13...

Page 39: ...Auto 3 101 120 Auto 4 121 140 Auto 5 141 160 Auto 6 161 180 Auto 7 181 200 Auto 8 201 220 Auto 9 221 255 Auto 10 12 18 Program Speed 000 255 Program speed adjustment from slow to fast 10 13 19 Dimmer...

Page 40: ...0015 STATUS_MESSAGES 0x0030 STATUS_ID_DESCRIPTION 0x0031 CLEAR_STATUS_ID 0x0032 SUPPORTED_PARAMETERS 0x0050 DEVICE_INFO 0x0060 DEVICE_MODEL_DESCRIPTION 0x0080 MANUFACTURER_LABEL 0x0081 DEVICE_LABEL 0x...

Page 41: ...l The controller is not connected Connect the controller The signal is reversed The 5 pin DMX OUT of the controller does not match the DMX IN of the device Install a phase reversing cable between the...

Page 42: ...at least 15 minutes before servicing or cleaning Preventive Maintenance Attention Before each use examine the device visually for any defects Make sure that All screws used for installing the device...

Page 43: ...solvents Make sure that the connections are fully dry before connecting the device to the power supply and to other devices Corrective Maintenance The device does not contain user serviceable parts D...

Page 44: ...This side up Fragile Storage Clean the device before storing Follow the cleaning instructions in chapter 8 2 1 Basic Cleaning Instructions on page 42 Store the device in the original packaging if poss...

Page 45: ...44 Performer 2000 RGBAL Product code 33038...

Page 46: ...45 Performer 2000 RGBAL Product code 33038...

Page 47: ...46 Performer 2000 RGBAL Product code 33038...

Page 48: ...2022 Showtec...

Reviews: