DATA CONNECTION
Depending on the length of the DMX cable run, or other factors, it may be advisable to install a
terminator at the last fixture in the run.
The illustration below shows the correct placement of a 120Ω 0.25W resistor in a terminator, as
well as the standard DMX signal pin-outs.
DMX INPUT
1
3
2
1
3
2
COMMON
DMX+
DMX-
DMX OUTPUT
1
3
2
120Ω
1/4 W
resistor
DMX INPUT
1
3
2
4
5
1
3
2
4 5
COMMON
DMX-
DMX+
Not Used
DMX OUTPUT
Not
Used
3
2
4
5
1
Relation between DMX and Address
Follow above method for subsequent fixtures, calculating starting addressed as indicated.
EXAMPLE OF DMX ADDRESSING
The below table shows an example of starting addresses for four fixtures assuming a first fixt-
ure with starting address of 001.
The actual starting addresses will be determined by the operator as needed to match external
controller settings.
043
14CH
32CH
118CH
001-014
001-032
001-118
001
015
029
096
355
001
001
033
119
065
237
START ADDRESS
4TH FIXTURE
MODE
ALLOCATION
START ADDRESS
1ST FIXTURE
START ADDRESS
2ND FIXTURE
START ADDRESS
3RD FIXTURE
9
10
11
12
13
14
DMX
/ NE
ww