Water warning: 

 
• Do not expose the device to rain, use it near water or in damp or wet conditions on it containing liquids which might spill 
into any openings. Never insert or remove an electric plug with wet hands. 
 

If you notice any abnormality: 

 
• If the power cord or plug becomes frayed or damaged, or if there is a sudden loss of sound during use of the device, or if 
any unusual smells or smoke should appear to be caused by it, immediately turn off the power switch, disconnect the 
electric plug from the outlet, and have the device inspected by qualified service personnel. 
 
 
 
 

INSTALLATION 

 

The Showlite PAR64 RGB LED-lighting effect is designed as floor effect or for overhead 
rigging on stages, in discotheques, theatres, etc. During installation consider all necessary 

safety instructions especially 

EN 60598-2-17

 and national standards. Please note: for 

overhead rigging in public or industrial areas, a series of safety instructions have to be 
considered. This manual can only give a survey and does not list complete instructions.  
Installation must only be done by authorized and experienced operators. 

 

 
Overhead rigging 

 

Important! Overhead rigging must only be done by authorized and experienced 

operators. Always install an appropriate safety bond.  

 

You must only use safety bonds and quick links complying with DIN 56927, shakles 
complying with DIN EN 1677-1 and BGV C1 carbines.All devices must be sufficiently 
dimensioned and used correctly in accordance to the latest industrial safety regulations. 
 
The installation oft he device hast o be built and constructed in a way that it can hold 10 
times the weight for 1 hour without any harming deformation. 
 
The maximum drop distance must never exceed 20 cm. 
 
A safety bond which already held the strain of a crash or which is defective must not be 
used again. 

 

 
 
 
 
 
 
 
 
 



 

Bedienungsanleitung

 

 
 
Inhaltsverzeichnis 

 
 
Vorsichtsmaßnahmen 

 

 

 

 

    3 

 
Montage und Inbetriebnahme 

 

 

 

    4 

 
Netzanschluss und DMX   

 

 

 

    5 

 
Rückseitige Anschlüsse und Bedienelemente   

    5 

 
Tastensperre und Bedienermenüs 

 

 

    5 

 
DMX512 Parameter  

  

 

 

 

    6 

 
 
 
 

Technische Daten PAR 64 LED RGB 
 

00022051 PAR-64 LED 10mm RGB 

00022052 PAR-64 36x3W RGB LED 

220/230 V / 50/60 Hz Schaltnetzteil 

eingebauter Lüfter 

interne Temperaturüberwachung 

177 Hochleistungs LEDs 10mm  

(R60, B56, G61) 

36x3W Hochleistungs LEDs 

(R12, B12, G12) 

Leistungsaufnahme 50W 

Leistungsaufnahme 160W 

LED Leistung 20W 

LED Leistung 108W 

DMX512 (7 Kanäle), manuell, Master/Slave, Audio Mode, Auto Run 

 

 
 
 
 
 

D
E
U
T
S
C

Summary of Contents for PAR64 LED

Page 1: ...s DICS Press Esc key then press Down to change dimmer value InSt instant mode DMX value will be changed immediately to new setting dELA delay mode DMX value will be changed slowly decrease increase from old to to new setting Master Slave To run several devices in Master Slave mode switch one device into auto or audio mode and switch all other devices to DMX address A001 The master will control aut...

Page 2: ...structions to avoid serious injuries or damage of the product Operators manual english start from page 7 D E U T S C H E N G L I S H 10 Power connection and DMX After save installation floor or overhead please connect the power cable to 220 230 V 50 60Hz power voltage You can operate the lighting device by an external DMX controller or by internal preset programs Auto Mode If using a DMX controlle...

Page 3: ... Important Overhead rigging must only be done by authorized and experienced operators Always install an appropriate safety bond You must only use safety bonds and quick links complying with DIN 56927 shakles complying with DIN EN 1677 1 and BGV C1 carbines All devices must be sufficiently dimensioned and used correctly in accordance to the latest industrial safety regulations The installation oft ...

Page 4: ...erious injury or even death from electrical shock short circuiting damages fire or other hazards These precautions include but are not limited to the following Power supply power cord devices with power cords power supplies Only use the voltage specified as correct for the device The required voltage is printed on the type plate of the device Check the power cable from time to time regarding dirt ...

Page 5: ... Stunde lang ohne dauernde schädliche Deformierung das 10 fache der Nutzlast aushalten kann Die Installation muss immer mit einer zweiten unabhängigen Aufhängung z B einem geeigneten Fangnetz oder Fangseil erfolgen Diese zweite Aufhängung muss so beschaffen und angebracht sein dass im Fehlerfall der Hauptaufhängung kein Teil der Installation herabfallen kann Der maximale Fallabstand darf 20 cm nic...

Page 6: ...en drei Audio Modi zu wählen D E U T S C H 6 Menu 4 Drücken Sie die Tasten Esc dann Down oder UP bis Sie im Display SoUd lesen Durch drücken der Enter taste wird der sound basierte Flash Modus aktiviert Menu 5 Drücken Sie die Tasten Esc dann Down oder UP bis Sie im Display Colr lesen Durch drücken der Enter taste erreichen Sie ein Menü in dem sich die verschiedene Farb Voreinstellungen aufrufen la...

Reviews: