4
CALIBRATION PROCEDURE
33
CALIB
R
ATION PR
OCE
DURE
Chapter
4
4-5.
Actual Load Calibration
Set the actual load value under an actual load.
Setting range:
-
99999 - 99999 (0 is excluded.)
How to set
1.
Press the [SET.] button.
(refer to page 32)
2.
Press the [Calibration] button.
(refer to page 32)
3.
Press the [Actual Cal.] button.
4.
Apply an actual load to the sensor, enter
the actual load value by the numerical
keys and determine with the [OK] button.
Also, set the decimal place here. To
eliminate a decimal point, register by
inputting a numerical value and then
pressing the decimal point key at the end.
4-6.
Equivalent Input Calibration
Set the rated output value and reading of the sensor.
Rated output value:
-
3.000 - 3.000mV/V (0 is excluded.)
Display value:
-
99999 - 99999 (0 is excluded.)
How to set
1.
Press the [SET.] button.
(refer to page 32)
2.
Press the [Calibration] button.
(refer to page 32)
3.
Press the [Equiv.Cal.] button.
4.
After pressing the [Rate Out] button,
enter the rated output of the sensor
with the numerical keys.
5.
After pressing the [Disp Val] button,
enter the display value with the
numerical keys. Also, set the decimal
place here. Press the [OK] button to
perform calibration. To eliminate a
decimal point, register by inputting a
numerical value and then pressing the
decimal point key at the end.
SET.
Calibration
Page 1
→
→
SET.
Calibration
Page 1
→
→