Application 

 

This gust blower is suitable for handling air and other incombustible, non-corrosive, and non-explosive gases. 

This gust blower is designed to allow continuous operation.  However, please note that frequent or repetitive 

ON/OFF  operation  or  use  in  a  high-temperature  environment  can  raise  the  gust  blower  to  the  maximum 

allowable temperature. For details, please contact us. 

Remove solid matters and impurities to prevent their entry into the gust blower.  

 

 

Suction and compression pressure 

 

Using the gust blower near its maximum static pressure causes temperature rise due to the compression heat 

and the overloading of the motor. Provide a pressure adjusting valve or a bypassnis hole on either the suction 

or discharge side to let out the air under such usage conditions. 

 

 

   

Temperatures 

 

The maximum allowable ambient temperature and gas temperature at the inlet are 40℃. 
The casing temperature while in operation is very high. Avoid touching to prevent burns. 

 
 

Installation 

 

The gust blower can be installed in any axial direction unless its cooling effect is impaired. Keep the 

ventilation grid and openings clean. The direction of flow is indicated with an arrow. 

 

When installing the gust blower in proximity of a wall, secure a minimum  of the following clearance 

between the gust blower and the wall:  

U2S-40T

70T

150

       

 20mm 

U2S-H220

H370

H750

   

 30mm 

Ensure ducting does not apply pressure or cause stress deformation to the gust blower.  

A built-in silencer reduces noise. To further reduce noise, use an auxiliary silencer (optional accessory).  

Thin or metal plating, etc. may conduct and amplify sound; if installing, be sure to install a sound-absorbing 

layer between the plate and unit.  

Summary of Contents for U2S

Page 1: ... this Showa Denki blower This Operation Manual describes the specifications for Gust Blower Type U2S Please read this Operation Manual carefully in particular where marked with a symbol for safe and efficient use of this blower Please keep this Operation Manual accessible for future use ...

Page 2: ...o let out the air under such usage conditions Temperatures The maximum allowable ambient temperature and gas temperature at the inlet are 40 The casing temperature while in operation is very high Avoid touching to prevent burns Installation The gust blower can be installed in any axial direction unless its cooling effect is impaired Keep the ventilation grid and openings clean The direction of flo...

Page 3: ... 1 Fig 1 2 according to the model power supply voltage and frequency to be used Wiring for U2S H220 H370 H750 For IE3 products the metal plate is removed at the time of product delivery It is included in the metal plate terminal box Connect the metal plates as shown in Table 2 Figures 3 to 5 according to the voltage in use The metal plate may be left over depending on the voltage used Use it if ch...

Page 4: ...plicable models U2S H220 H370 H750 No of terminals 50Hz 60Hz 200V 220V 9 9 60Hz 200V 9 60Hz 380V 400V Table 2 Connecting outlet line IE3 Metal plate Figure 3 Δ wiring Figure 4 YY wiring Figure 5 Y wiring Power line inlet Power line inlet Power line inlet ...

Page 5: ...fective at a gas inlet and ambient temperatures of 40 The motor current will rise by 6 at a gas inlet and an ambient temperature of 20 Set the motor protection circuit breaker to the rated current value Be sure to connect a grounding wire to prevent electric shock hazards ...

Page 6: ...E1 U2S 70T 3 0A 4 0A 3 8A Fig 1 IE1 U2S 150 7 0A 8 8A 8 5A Fig 1 IE1 Table 5 IE3 Electric Motor 200V class Rated current Wiring IE code Frequency 50Hz 60Hz Voltage 200V 200V 220V U2S H220 9 9A 12 0A 10 4A 50Hz Fig 3 IE3 60Hz Fig 4 IE3 U2S H370 17 1A 19 6A 16 9A 50Hz Fig 3 IE3 60Hz Fig 4 IE3 U2S H750 30 8A 35 2A 30 5A 50Hz Fig 3 IE3 60Hz Fig 4 IE3 Table 6 IE1 Electric Motor 380 400V Rated Current S...

Page 7: ... 1 IE1 U2S 150 7 0A 8 8A 8 5A 7 0A 8 8A 8 5A Fig 1 IE1 Table 9 IE3 Electric Motor 200V class Discharge side Suction side Wiring IE code Frequency 50Hz 60Hz 50Hz 60Hz Voltage 200V 200V 220V 200V 200V 220V U2S H220 9 9A 12 0A 10 4A 9 9A 12 0A 10 4A 50Hz Fig 3 IE3 60Hz Fig 4 IE3 U2S H370 17 1A 19 6A 16 9A 13 1A 18 4A 16 9A 50Hz Fig 3 IE3 60Hz Fig 4 IE3 U2S H750 30 8A 35 2A 30 5A 22 9A 32 6A 30 5A 50H...

Page 8: ...re below the maximum operating static pressure and current If pressure is above the maximum operatic static pressure provide a bypass hole to let air out Operating status No abnormal vibration or noise If any please contact us Maintenance inspections We recommend checking for any deterioration in insulation and for abnormal vibration or noise every three months The motor bearing uses a sealed ball...

Reviews: