Show UP-88H/8H User Manual Download Page 7

Generally, each model is equipped with the typical type of capsule for specific sound 
characteristic, and the RF design keeps the same, please refer to the following specification 
of the capsules for more information on the microphone selection to your system.   

Type: Dynamic Mic.
Frequency response: 50Hz~15kHz( 3dB)
Impedance: 270

  20% at 1kHz

Sensitivity: 0.005%
Direction: Omni-directional

S-100

Type: Dynamic Mic.
Frequency response: 50Hz~16kHz( 3dB)
Impedance: 300

  20% at 1kHz

Sensitivity: -71dB  3dB
Direction: Omni-directional

S-600

2

17

6. ANNEX

Most countries closely regulate the radio frequencies used in the transmission of 
wireless information. These regulations state which devices can use which frequencies, 
and help to limit the amount of RF(radio frequency)interference in all wireless 
communications.To be flexible enough to operate worldwide, UR-81DR Wireless 
receivers  are available in a number of models, each with a unique frequency range. 
Each frequency range, or band, spans up to 24MHz of the wireless broadcast 
spectrum. Available bands are:

6.1 Frequency Band Selection 

F1:470.000-494.000(470-496)MHz          F2:518.000-542.000(518-544)MHz
F3:572.000-596.000(572-598)MHz          F4:638.000-662.000(638-664)MHz
F5:702.000-726.000(702-731)MHz          F6:740.000-764.000(740-769)MHz
F7:798.000-822.000(798-827)MHz          F8:850.000-874.000(850-879)MHz

6.2 Frequency Ranges

Group1

Group2

Group3

Group4

Group5

Group6

1

2

3
4

5

6

7

8

9

10

11

12

F1: 470.000-494.000(470-496)MHz          

F1: 470.000-494.000(470-496)MHz          

470.125 

470.325 

470.525 

470.725 

470.925 

471.125 

471.325 

471.525 

471.725 

471.925 

472.125 

472.325 

472.525 

472.725 

472.925 

473.125 

473.325 

473.525 

473.725 

473.925 

474.125 

474.325 

474.525 

474.725 

474.925 

475.125 

475.325 

475.525 

475.725 

475.925 

476.125 

476.325 

476.525 

476.725 

476.925 

477.125 

477.325 

477.525 

477.725 

477.925 

478.125 

478.325 

478.525 

478.725 

478.925 

479.125 

479.325 

479.525 

479.725 

479.925 

480.125 

480.325 

480.525 

480.725 

480.925 

481.125 

481.325 

481.525 

481.725 

481.925 

482.125 

482.325 

482.525 

482.725 

482.925 

483.125 

483.325 

483.525 

483.725 

483.925 

484.125 

484.325 

Summary of Contents for UP-88H/8H

Page 1: ...6757 http www show pa com e mail sekaku sekaku com All rights reserved to SEIKAKU All features and content might be changed without prior notice Any photocopy translation or reproduction of part of th...

Page 2: ...before operating this unit for the first time All rights reserved to SHOW All features and content might be changed without prior notice Any photocopy translation or reproduction of part of this manu...

Page 3: ...unding terminal Operating Conditions This apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on this apparatus To reduce the...

Page 4: ......

Page 5: ...oup9 Group10 Group11 Group12 702 125 702 325 702 525 702 725 702 925 703 125 703 325 703 525 703 725 703 925 704 125 704 325 704 525 704 725 704 925 705 125 705 325 705 525 705 725 705 925 706 125 706...

Page 6: ...UP 86H 886H Dynamic S 500 UP 87CH 887CH Condenser C 100 UP 88CH 888CH Condenser C 200 18 F3 572 000 596 000 572 598 MHz F3 572 000 596 000 572 598 MHz F2 518 000 542 000 518 544 MHz F2 518 000 542 000...

Page 7: ...uency range Each frequency range or band spans up to 24MHz of the wireless broadcast spectrum Available bands are 6 1 Frequency Band Selection F1 470 000 494 000 470 496 MHz F2 518 000 542 000 518 544...

Page 8: ...ncy stability T H D Modulation mode RF output power Dynamic Tone frequency Current drain Max Deviation Battery Optional Mic Capsule optional Dimensions Weight UP 88H 8H PLL UHF SYNTHESIZED UHF 470 900...

Page 9: ...IFICATIONS 430 W 210 D 44 H mm 9 01 17 04 1 97 2 042Kg C 200 Type Condenser Mic Frequency response 100Hz 15kHz 3dB Impedance 700 30 at 1kHz Sensitivity 44dB 3dB Direction Uni directional UP 8P 88P ser...

Page 10: ...Scan function for easy and convenient operation Switching diversity control to receive the RF signal Three output level versions Squelch control UP 8H 88H 8P 88P transmitters Soft touch painting for...

Page 11: ...geable batteries are used Please keep the batteries inside and use the charger optional accessory provided by the manufacturer to recover the batteries During the charging process the Remaining batter...

Page 12: ...er version Several seconds later after that the system stores the settings automatically and LCD display comes back to the main menu which shows the current operation status RF Output Power Select Thr...

Page 13: ...tus Fig 6 Preset frequency Remaining battery life 4 2 1 Edit The Parameter Frequency select It is the multi channels PLL synthesized system In practice to effectively avoid the interference from any l...

Page 14: ...noise Besides that a too high squelch threshold also decreases the usable range In the squelch control mode fig 5 use the UP DOWN key to select squelch threshold The job of a squelch circuit is to re...