background image

USER MANUAL

Series:

VN92

ATTENTION!

DANGER!

Read all safety rules carefully before attempting to operate. Retain for 
future reference.

Never operate this unit when flammable materials or 
vapors are present because electrical devices produce 
arcs or sparks that can cause a fire or explosion. NEVER 
OPERATE UNATTENDED!

For your records, please record the following information

and store this user manual in a safe location.

Catalog No.

Model No.

Purchase Date:

(Located on the carton)

(Located on top portion of the vacuum)

87550-66

Household and Workshop use
WET/DRY VACUUM

Summary of Contents for VN92 SERIES

Page 1: ...or vapors are present because electrical devices produce arcs or sparks that can cause a fire or explosion NEVER OPERATE UNATTENDED For your records please record the following information and store t...

Page 2: ...Up and Operation Filter Installation and Maintenance Blower Feature Emptying Liquid Waste from the Tank Automatic Suction Shut Off Lubrication Storage Troubleshooting Warranty and Contact Information...

Page 3: ...se paints lacquers household cleaners etc 17 Do not vacuum toxic carcinogenic combustible or other hazardous materials such as asbestos arsenic barium beryllium lead pesticides or other health endange...

Page 4: ...tance where an extension cord becomes necessary a 3 conductor grounding cord of adequate size must be used for safety and to prevent loss of power and overheating Use Table A to determine A W G wire s...

Page 5: ...he holes provided Apply pressure and twisting motion until casters snap into place SET UP AND OPERATION DANGER This equipment incorporates parts such as switches motors or the like that tend to produc...

Page 6: ...dealer or the Shop Vac website e Plug the cord into the wall outlet Your large capacity vacuum is ready for use I ON O OFF FILTER INSTALLATION AND MAINTENANCE Dry Pick Up Operation NOTE Never use the...

Page 7: ...ine dust or powders a high efficiency filter bag must be used NOTE For dry use only 1 Make sure the cord is disconnected from the receptacle tank cover is removed and the hose is disconnected from tan...

Page 8: ...This can be accomplished with a warm solution of soap and water FOAM SLEEVE 1 With the tank cover in an upside down position slide the foam sleeve down over the lid cage pulling until foam sleeve com...

Page 9: ...it seats itself against a seal at the intake of the motor shutting off suction When this happens the motor will develop a higher than normal pitch noise and the suction is drastically reduced If this...

Page 10: ...rt Visit www shopvac com for your vacuum s parts list schematic Customers in Canada for product service return the complete unit transportation prepaid to the Authorized Shop Vac Service Centre neares...

Page 11: ...hopvac com SHOP VAC CANADA 1770 Appleby Line Burlington Ontario L7L 5P8 905 335 9730 www shopvac ca Shop Vac M xico S A de C V Paseo de los Adobes 1081 3 Fraccionamiento Guadalajara Technology Park Za...

Page 12: ...PAGE 12...

Page 13: ...que los artefactos el ctricos producen arcos o chispas que pueden causar un incendio o una explosi n NUNCA DEJE LA ASPIRADORA FUNCIONANDO SIN VIGILANCIA Para uso dom stico y empresarial ASPIRADORA PAR...

Page 14: ...laci n y mantenimiento del filtro Funci n de soplador Vaciado de residuos l quidos del dep sito Apagado autom tico de la succi n Lubricaci n Almacenamiento Soluci n de problemas Garant a e informaci n...

Page 15: ...o cenizas calientes 12 No lo utilice sin colocarle antes la bolsa para polvo y o los filtros 13 Apague todos los controles antes de desconectar la unidad 14 Extreme precauciones cuando est limpiando...

Page 16: ...ta pueda instalar una toma de corriente debidamente conectada a tierra ilustraci n A La espiga r gida de color verde orejeta o accesorio similar que sale del adaptador debe conectarse a una conexi n a...

Page 17: ...ares y alzando las leng etas de la tapa del dep sito Saque los accesorios que pudieron haber sido enviados junto con el dep sito Consulte la secci n montaje antes de volver a colocar la tapa de los de...

Page 18: ...locar la tapa del dep sito peque o alineando las leng etas con las orejetas Presione firmemente hacia abajo sobre el alojamiento superior hasta que la tapa del dep sito se encaje en su lugar Aseg rese...

Page 19: ...alga del alojamiento de la tapa NOTA Si el filtro de cartucho ha sido utilizado para la aspiraci n de materiales l quidos se deber limpiar y dejar secar antes de utilizarlo para la aspiraci n de mater...

Page 20: ...ridad Cuando est en su lugar de forma segura abra la bolsa y col quela alrededor del interior del dep sito 6 NOTA Al extraer la bolsa de filtro del dep sito extraiga el deflector de entrada del collar...

Page 21: ...de la tapa grande 3 Para limpiar la manga de hule espuma sostenga la cubierta del dep sito y gire el retenedor del filtro en sentido contrario a las agujas del reloj para soltarlo y retirarlo si est...

Page 22: ...p sito un flotador interno se eleva hasta que se asienta contra un sello en la entrada del motor apagando la succi n Cuando esto ocurre el motor producir un ruido muy agudo y se reducir dr sticamente...

Page 23: ...A LA PROPIA ASPIRADORA DEBER REPARARSE LA ASPIRADORA ANTES DE PODER UTILIZARLA NUEVAMENTE GARANT ADEUSODOM STICOPORTRESA OS Su aspiradora Shop Vac est garantizada para uso dom stico normal de acuerdo...

Page 24: ...OM STICOPORTRESA OS CONT Clientes en los Estados Unidos para soporte t cnico p ngase en contacto con Shop Vac Corporation Atenci n al Cliente al n mero 570 326 3557 o visite www shopvac com support Vi...

Reviews: