TROUBLESHOOTING
ISSUE
POSSIBLE CAUSE(S)
CORRECTIVE ACTION
Parts/accessories missing
1. Packed in tank
1. Check in tank.
Vacuum cleaner will not start
1. No power at receptacle
2. Defective switch
3. Defective motor
1. Check for power.
2. Replace switch.
3. Replace motor.
Dust discharging from exhaust
1. Filter not installed or installed
improperly
2. Filter damaged
3. Filter clogged or dust is
too fine
4. Filter not functional
1. Properly install filter.
2. Replace filter.
3. Use more efficient filter.
4. Clean and replace filter.
Loss of suction
1. Loose hose connection
2. Filter clogged
3. Full tank
4. Hole in hose
1. Tighten hose connection.
2. Clean or replace filter.
3. Empty tank.
4. Replace hose.
Static shock
1. Dry environment
2. Relative humidity of air is low
1. Add moisture to air
(if practical, use a console or
installed humidifier).
2. This situation is temporary
and does not affect use of
vacuum cleaner.
π