Page 1: ...360 734 3482 Online Technical Support tech support shopfox biz COPYRIGHT OCTOBER 2010 BY WOODSTOCK INTERNATIONAL INC WARNING NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT T...

Page 2: ...Z j Zlkk e jXe e i e e kffc ek i kp Xe k_ ljX f g ijfeXc gifk Zk m hl gd ek K_ dXel XZkli i n cc efk Y _ c c XYc fi ealip fi gifg ikp XdX ifd e c eZ dgifg i kiX e e dXZ_ e df ZXk fej fi d jlj Jfd ljk...

Page 3: ...10 SETUP 11 Unpacking 11 Inventory 11 Machine Placement 13 Assembly 14 Test Run 19 COLLECTION SYSTEM 20 System Setup 20 Duct Material 21 System Grounding 23 OPERATIONS 24 General Operation 24 Remote...

Page 4: ...s manual please contact us at Woodstock International Inc Attn Technical Documentation Manager P O Box 2309 Bellingham WA 98227 Email manuals woodstockint com The Model W1823 is a 2 stage cyclone dust...

Page 5: ...e view Remote Magnetic Switch Blower Housing Motor Filter Cleaning Handle Canister Filter Vacuum Hose Cyclone Funnel Outlet Port 6 x 4 Y Adapter 6 Inlet Quick Release Lever Stand Leg Drum Handle Drum...

Page 6: ...of Water 10 4 Main Inlet Size 6 4 x 6 Y Adapter Included Yes Y Adapter Main Port Size 6 Number of Y Adapter Inlets 2 Y Adapter Inlet Size 4 Machine Material Collection Capacity 4 3 cu ft Canister Fil...

Page 7: ...e 60 Hz Switch Magnetic Switch w Thermal Overload Protection Switch Voltage 110V Phase Single Phase Cord Length 7 ft Cord Gauge 14 gauge Required Power Supply Circuit 20 15 Amp Plug Included Yes Recom...

Page 8: ...slip footwear to avoid accidental slips which could cause a loss of workpiece control 8I E GIFK K FE Always wear hearing protection when operating or observing loud machinery Extended exposure to this...

Page 9: ...contact with moving parts or flying debris Make sure they are properly installed undamaged and working correctly before using machine E M I JK8E FE D8 E Serious injury or accidental contact with cutti...

Page 10: ...cause an allergic reaction in people and animals Make sure you know what type of wood dust you will be exposed to in case there is a possibility of an allergic reaction DGKP E LJK When emptying dust f...

Page 11: ...on a 220V power supply details about voltage conversion can be found later in this manual The 220V power supply circuit must have a verified ground and meet the requirements that follow Circuit Type...

Page 12: ...in accordance with local codes and ordinances For 110V Connection Prewired A NEMA 6 15 plug has a grounding prong that must be attached to the equipment grounding wire inside the included power cord T...

Page 13: ...shipping Main Inventory Figure 5 Qty A Outlet Port 1 B Outlet Port Gasket Set 1 C Blower and Collector Assembly 1 D Magnetic Switch Assembly for 110V 1 E RF Remote Control 1 F Collection Drum 1 G Cycl...

Page 14: ...e 2 G Button Head Cap Screws 5 16 18 x 1 2 Legs 36 H Button Head Cap Screws 5 16 18 x 3 4 Outlet Port to Canister 6 I Button Head Cap Screws 5 16 18 x 1 2 Outlet Port to Blower Housing 8 J Hex Wrench...

Page 15: ...is operated is important for safe operation and the longevity of its components For best results operate this machine in a dry environment that is free from excessive moisture hazardous chemicals air...

Page 16: ...carefully as not to scratch the paint 2 Fasten the three upper legs to the leg support bosses on the blower housing with 12 5 16 18 x 1 2 button head cap screws as shown in Figure 9 3 Thread the cast...

Page 17: ...he canister filter in place while you fasten the outlet port and its smaller gasket to the blower housing with 8 5 16 18 x 1 2 button head cap screws as shown in Figure 14 11 Reach inside the canister...

Page 18: ...acuum tube installed Figure 16 Inlet Y adapter installed Screw Figure 17 Collection drum cover seal and lift cable clamping location 14 Fasten the inlet Y adapter to the intake barrel suction port and...

Page 19: ...ire between the drum cover and leg with the included 2 5 16 18 x 1 2 flange screws as shown in Figure 20 This wire prevents accumulation of static electricity at the collection drum 20 Position the li...

Page 20: ...cover roll the drum under the lid and push the lever upward to lower the lid on the drum see Figure 24 Note The lid is not designed to rest on top of the drum with any real force nor is it designed to...

Page 21: ...to turn the machine ON 6 Listen and watch for abnormal noises or actions The machine should run smoothly with little or no vibration or rubbing noises Strange or unusual noises must be corrected befo...

Page 22: ...chines as short as possible Note that flex hose reduces CFM more than smooth walled duct Keep ducting directional changes to a minimum The more curved fittings you use the more resistance to flow resu...

Page 23: ...ugh the duct Since metal duct is a conductor it can be grounded quite easily to dissipate any static electrical charges There are quite a number of options when it comes to metal duct but metal duct t...

Page 24: ...ompletely flexible is non resistant to abrasion and has a tendency to collapse in a negative pressure system We DO NOT recommend using dryer drainage type vent hose in your dust collection system If u...

Page 25: ...gates the system must still be grounded as mentioned above We recommend inserting a continuous bare copper ground wire Figure 29 inside the entire duct system and attaching the wire to each grounded...

Page 26: ...ncoming air that extracts most dust particles and drops them into the steel collection drum below while the remaining fine dust see Figure 31 travels past the impeller and into the canister filter The...

Page 27: ...wn time from always ON to timed operation intervals of 2 hours 4 hours 6 hours and 8 hours When illuminated the red LED lamp indicates which timed operation mode the machine is in If the motor gets to...

Page 28: ...p quality aluminum blast gates feature a cast aluminum body with steel gate and locking knob The following types and mod els are available The Model W1055 Dust Collection Accessories Kit 2 provides th...

Page 29: ...ssary Check loose mounting bolts and ducting Check worn or damaged wires Check system for leaks Check for tears in the filter or bags Look for any other unsafe condition General Your cyclone dust coll...

Page 30: ...the sun to dry or it could shrink and distort Washing the filter when the ambient temperature is below 65 degrees or placing the wet filter in a closed environment without ventilation to dry can cause...

Page 31: ...riple beep is heard The original remote control code is now erased 6 Press and hold the reset button for 1 second The receiver is ready for the new code 7 On the remote control press and hold the ON b...

Page 32: ...rease the risk of serious personal injury fire or machine damage If you notice that any wires or components are damaged while performing a wiring task replace those wires or components before completi...

Page 33: ...otor Prewired for 110V Motor Junction Box Rewired for 220V Thermal Overload ON Rewired for 220V Rewired for 220V 7V 0V 120V 0V Transformer 50 60Hz Hot Hot Hot Neutral Ground Ground 110 VAC 220V 6 15 P...

Page 34: ...n twisting a wire nut over them Once snug wrap the wire nut and the wires it contains with electrical tape to reduce the likelihood of the wire nut loosening during use and reinstall the junction box...

Page 35: ...ey were in on the 110V switch Tighten all terminals 10 At this point the new remote control receiver inside your new magnetic switch must be reprogrammed so it can communicate with your old hand held...

Page 36: ...ter cooling 7 Replace start capacitor 8 Replace remote control or receiver 9 Replace motor Motor runs slower than normal 1 Poor electrical connection 2 Run capacitor at fault 3 Motor is wired incorrec...

Page 37: ...ate 11 The dust collector is too small for the dust collection system 1 Empty collection drum 2 Clean filter empty collection drum 3 Use the correct size duct collector for the type of machine 4 Remov...

Page 38: ...4A 24 25 26 27 28 29 30 31 32 33 34 35 36 73 72 39 40 42 43 45 46 47 48 49 50 51 52 53 54 55 56 56 1 56 2 56 4 56 5 57 58 91 59 60 61 62 63 65 66 67 68 69 86 74 12 13 71 37 38 14 31 90 34A 56 3 56 4 4...

Page 39: ...AT WASHER 1 4 18 X1823018 COLLECTION DRUM LID 59 XPB05 HEX BOLT 1 4 20 X 3 4 19 XPS12 PHLP HD SCR 1 4 20 X 5 8 60 X1823060 INLET PORT CAP 20 X1823020 COLLECTION DRUM HANDLE 61 XPS01 PHLP HD SCR 10 24...

Page 40: ...before allowing the machine to enter service again Contact Woodstock International Inc at 360 734 3482 or www shopfoxtools com to order new labels REF PART DESCRIPTION REF PART DESCRIPTION 75 X1823075...