ON
POSITION
OFF
POSITION
Figure 6 - Equipment Shutoff Valve
Open
Closed
Equipment
Shutoff
Valve
PRESSURE TESTING APPLIANCE
GAS CONNECTIONS
1. Open equipment shutoff valve (see
Figure
14
).
2. For natural gas, open main gas valve located on or near
gas meter. For propane/LP gas, open propane/LP supply
tank valve.
3. Make sure control knob of
is in the OFF posi-
tion.
4. Check all joints from equipment shutoff valve to gas
control valve. Apply noncorrosive leak detection
to all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light replace (see
Operating Log Set,
page 1 4) Check
all other internal joints for leaks.
7. Turn off replace (see
To Turn Off Gas To Log Set,
page
15).
INSTALLATION
Test Pressures Equal To or Less Than 1/2
PSIG (3.5 kPa)
1. Close equipment shutoff valve (see
Figure 6
).
2. Pressurize supply piping system by either opening
propane/LP supply tank valve for propane/LP gas or
opening main gas valve located on or near gas meter of
natural gas or using compressed air.
3. Check all joints from gas meter to equipment shutoff
valve for natural gas or propane/LP supply to equipment
shutoff valve for propane/LP. Apply noncorrosive leak
detection
to all joints. Bubbles forming show a
leak.
4. Correct all leaks at once.
CONTINUED
10
OPTIONAL REMOTE CONTROL SET
INSTALLATION AND SET-UP
Install three
(
3) "AAA"
batteries into the
remote control
as shown on the left.
Install four
(
4) "AA"
batteries into the
remote receiver box
as shown on the left.
+
-
+
Transmission
light
Side
Slide
Switch
ON/OFF
Key
Remote control purchased seperatly.
Summary of Contents for IVFMV18LP
Page 11: ...Figure 7 Log Placement Savannah Oak 18 11 ...
Page 12: ...Figure 8 Log Placement Savannah Oak 24 and 30 ...
Page 13: ...Log Placement CVO 18 24 30 MV 18 24 VFM And OVM21 13 Figure 9 Log Placement CVO MV and OVM ...
Page 20: ... See Fig 21 See Fig 22 Figure 22 Pilot Inlet Air Hole 19 ...
Page 21: ...19 19 19 19 19 19 18 ...
Page 22: ...22 ...
Page 26: ...NOTES ...
Page 27: ...NOTES ...