1.4.2 Table 10 DC Output Over current Protection. (
输出过流保护
)
-
-
12V
Hiccup
尝试重复启动
故障去除后,关掉
Ps-on
信号再打开,电源即可恢复。
24V
Hiccup
尝试重复启动
12V
5.0V
≥3Atyp*
Output Voltage
≥4Atyp*
Hiccup
尝试重复启动
Hiccup
尝试重复启动
≥4Atyp*
Output Voltage
Hiccup
尝试重复启动
24V
≥2.0Atyp*
Hiccup
尝试重复启动
Note:* The Short Circuit protection should be test at other of dc output at min load
短路保护测试是在其它最小负载
时测试
.
1.4.4 Reset After Shutdown.
(保护功能复位)
Recycle the ps-on signal, the power supply will restart after the fault removed.
Comments
Note:* The over current protection should be test at other of dc output at Rated load but the 24V over current protection
should be test at 12Vdc output at min load.5V
和
5VSTB
过流保护测试是在其它额定负载时测试
.
而
24V
过流测试是在
12V
轻载电流时测试
Hiccup
尝试重复启动
5.0VSB
1.4.3 Table 11 DC Output Short Circuit Protection. (
输出短路保护
)
LATCH
5.2VSB
Over Current
Comments